‘Unidelta Deltapress’ range of brass press-fit fittings for use with ‘Unidelta Flexall’ PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
‘HE-705X & HE-715X’ ranges of brass crimp fit fittings incorporating EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057-2006). HE-7052/7053/7058/7059 & HE-7152/7153/7158/7159 models also incorporate a NBR gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
VSH XPRESS Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of PVC-u solvent weld and threaded union fittings incorporating an EPDM ‘O’-ring. For use with PVC-u pipe manufactured to ISO 1452 and DIN 8063. Maximum working pressure 10.0 bar. Cold water use only.
‘Xpress’ range of press fit fittings with copper or brass bodies and EPDM ‘O’-rings. For use with copper tube manufactured to EN1057. For above ground ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘Endex’ range of copper alloy and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of gas fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The cold inlet incorporates an angled spherical valve with a brass body, chromium plated brass ball and a lever operating member. The primary circuit incorporates an expansion vessel, isolation valves on flow and return, drain valve and a pressure relief valve set at 3.0 bar. Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature for the secondary circuit is 55˚C. Cold supply only.
Range of air cooled ice making machines . Inlet is controlled via solenoid valve. Maximum working pressure 5.5 bar. Cold water use only.
Range of in-line water meters with brass bodies and plastic inlet filters. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C (SJ & ELECTO-SJ models) Maximum operating temperature 30°C (AP VARIO and AP RADIO models)
Page 239 of 1168
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.