Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve.
Maximum working pressures:
T (oval flange): 16.0 bar.
V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar.
Maximum operating temperature 100°C.
- Section:
- 1610 Pumps
- Section Subtitle:
- Wholesome water use.
- WRAS Approval Number:
- 2110066
- Size:
- EV1-EV3 & 1VR-3VR models - F (round flange) versions: DN25.
EV6-EV20 & 6VR-20VR models - F (round flange) versions: DN32-50.
EV1-EV20 & 1VR-20VR models - T (oval flange), V (Victaullic - EV; Grooved - VR), C (clamp flanges) & F (round flange) versions: DN32-50.
- Marking:
- Franklin Electric, model name, date of production (DD/MM/YYYY), pressure, temperature and other technical information on data plate on body.
- Installation Requirements:
- R001 R415
- Expiry date:
- 31/10/2026
- Model:
-
EV and VR ranges.
Code example (EV range):
EV 20 /15 A B C D E F G H J K L M N PMP/A.
Where:
EV = Pump model EV (EV = E-Tech “brand”).
20 = Rated flow [m³/h] (varies: 1-20).
/15 = No. of stages/impellers. (See model and stages below for more detail).
A = No. of trimmed impellers, if "Empty" = none.
B = Flange type: "F" - round; "T" - oval; "V" - Victaulic; "C" - clamp.
C = Materials: "I" - (AISI304/EN1.4301); "N" (AISI316/EN1.4401).
D = Motor power (kW x 10).
E = Frequency: "5" - 50Hz; "6" - 60Hz.
F = No. of motor poles: "Empty" - 2 poles; "4" - 4 poles.
G = Motor type: "Empty" - without motor, "T" - 3-phase; "M" - 1-phase.
H = Mechanical Seal: "Empty" - standard version (EV1-EV20 & 1VR-20VR versions only).
J = Type of mechanical Seal: E1 (SiC-Carbon Graphite-EPDM) or E2 (SiC-SiC-EPDM).
K = "Empty" - standard version, "H" - high pressure.
L = "Empty" - standard version, "P" - passivated.
M = "Empty" - standard version
N = "Empty" - no motor, “IE..” motor efficiency class.
PMP/A = cold formed pump casing.
Code example (VR range):
3 VR0700 A B C X-XXXX.
Where:
3 = Rated flow [m³/h] (varies: 1-20).
VR = Pump model (VR = FPS “brand”).
07 = No. of stages/impellers. (See model and stages below for more detail).
00 = Impeller trim: 00 = no trim, A1 = 1A (one trimmed impeller), A2 = 2A (two trimmed impellers).
A = Materials: "H" - (AISI304/EN 1.4301); "N" (AISI316/EN 1.4401).
B = Flange type: "F" - round; "T" - oval; "V" - Grooved (Victaullic); "C" - clamp.
C = Mechanical Seal: “1” - QBE; “2” - QQE.
X-XXXX = Combination of numbers and letter relating to frame, speed, motor and electronics (does not affect water pathways). Last two digits can be empty for versions without a motor.
Minimum and maximum number of stages (please note the oval flange models have a lower maximum, this is included in brackets as follows [15] to denote 15 stages):
EV1/1VR: stage from 2 to 37 [23] (50Hz) and from 2 to 25 [15] (60Hz);
EV3/3VR: stage from 2 to 33 [21] (50Hz) and from 2 to 23 [14] (60Hz);
EV6/6VR: stage from 2 to 36 [21] (50Hz) and from 2 to 23 [14] (60Hz);
EV10/10VR: stage from 2 to 24 [15] (50Hz) and from 2 to 17 [10] (60Hz);
EV15/15VR: stage from 1 to 17 [10] (50Hz) and from 1 to 12 [10] (60Hz);
EV20/20VR: stage from 1 to 17 [10] (50Hz) and from 1 to 10 [7] (60Hz).
Product Images
- Approval Holder:
- Franklin Electric SRL
Company Name
Franklin Electric SRL
Address
Via Asolo 7
Dueville
Vicenza
36031
Country
Italy
Phone
+39 0444 360366
General Email
info.it@fele.com
View All Listings by this Company