Bar type thermostatic blending valve with a chromium plated brass body, a quarter turn ceramic disc headwork with single lever type operating member controlling the flow. Temperature is controlled by a thermostatic mixing valve with a single lever type operating member incorporating with a manual override button. The inlets incorporate stainless steel strainers and approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of floor standing, shower to shower, thermostatic blending valves (brass or stainless steel, various finishes, see models). Incorporating a ceramic cartridge headwork with a single lever operating member. The product incorporates a self-cancelling diverter to overhead shower with a dome operating member. The outlet of the diverter incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also supplied with shower hose and shower handset. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Wall mounted, thermostatic blending valve (brass body) incorporating a single sequential headwork and dome operating member. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Range of wall mounted thermostatic bar shower mixers (chrome plated brass bodies) incorporating a two-way ceramic disc diverter with a dome or cubed type operating member. The temperature is controlled independently via a thermostatic cartridge with dome or cubed type operating members that incorporate a manual override button. The inlets incorporate stainless-steel strainers and approved single check valve cartridges, however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection. The products are supplied with shower hose, handset, overhead shower and riser rail assembly. Maximum working pressure:10.0 bar. Maximum operating temperature: 65°C.
Range of thermostatic blending valves, (brass bodies – various finishes), incorporating a thermostatic cartridge. The product is supplied with various trim sets incorporating a cross top, lever or dome type operating member. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 5 bar. Maximum operating temperature 85°C.
Range of concealed and exposed two-way diverters, (brass bodies – various finishes, trim sets and operating members). The inlets on XX1650YY and XX1721YY models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C (PSA019 YY, PSA020 YY & XX1782YY) Maximum operating temperature 60°C (PSH049, XX1650YY, RZ/1721 & XX1721YY).
Range of pre-set pressure relief valves with a DZR brass body, incorporating an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Compression connection for use with copper tube to BS EN 1057. Maximum working pressure: see models. Maximum operating temperature: 23.0°C
Range of cold-water inlet control groups consisting of an in-line, manually adjustable pressure reducing valve and a pressure relief valve pre-set at either 6.0 or 8.0 bar, housed within DZR brass bodies. The products incorporate approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. The pressure reducing valves also have stainless-steel strainers. Maximum inlet pressure 16.0 bar. Cold water use only. CWIC351300 – Outlet pressure range 1.0 to 3.5 bar. Pressure relief valve set at 6.0 bar CWIC351301 – Outlet pressure range 1.0 to 2.1 bar. Pressure relief valve set at 8.0 bar. CWIC351303 – Outlet pressure range 1.0 to 3.5 bar. Pressure relief valve set at 8.0 bar CWIC351306 – Outlet pressure range 1.5 to 6.0 bar. Pressure relief valve set at 8.0 bar
Inlet control group with a DZR brass body, consisting of a pressure reducing valve and pressure relief valve (6.0 Bar). The inlet incorporates a stainless-steel strainer, and the outlet incorporates an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The product is for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C. Outlet pressure range of the pressure reducing valve is 1.0 to 4.0 bar.
In-line polyphosphate scale inhibitor. The product is supplied with a single check valve cartridge in the inlet connection, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 5.0 bar. Cold water use only.
Page 231 of 280
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.