Range of single hole, double outlet (fixed) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied). The spout outlet of ‘Arc’ models incorporates a plastic flow straightener. All models incorporate a separate vent outlet within the tap spout for the near-boiling water circuit. Near-boiling circuit has a maximum operating temperature 100°C. Hot-water circuit has a maximum operating temperature of 65°C.
Range of two hole, single outlet (fixed) combination tap assemblies incorporating brass body (chromium plated) and ceramic disc headwork with dome type operating members The temperature is controlled independently via a thermostatic cartridge with dome type operating member and manual override button. The spout outlet incorporates a plastic flow straightener. Both inlets incorporate a stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Two hole, single outlet (fixed), combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Wall mounted two hole, metal, single outlet (fixed) combination tap assembly (brass body in various finishes - see model), incorporating a 2 way ceramic disc diverter controlling the flow between the spout outlet and the shower outlet with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. The spout outlet incorporates a plastic aerator. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating rising spindle headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
A range of combined bath filler and overflow with a plastic body with a variety of different trims. The products are supplied with a cable operated pop-up waste. For open outlet use only. Maximum operating temperature 65°C.
Range of water filter systems with optional distributor heads. The inlets incorporate a non-return valve. Maximum working pressure 6.9 bar. Cold water use only.
Range of complete water filter heads and compatible filter cartirdges with plastic bodies and EPDM ‘O’-rings. The FX filters are carbon block based and the VH-IEN filters use an ion exchange resin. Maximum working pressure 8.6 bar. Cold water use only.
Uponor S-Press (black and grey) composite fittings, Uponor S-Press composite PPSU reducers with S-Press PLUS composite PPSU nipples, Uponor RS fittings & Uponor S Press Metal Press fittings for use with for use with Uponor MLC pipe. Maximum working pressure and operating temperature: 10.0 bar@70°C Maximum working pressure and operating temperature: 16.0 bar @ Cold water use only.
Range of Eco Duo copper press fittings with EPDM ‘O’-rings for use with Eco-Duo copper tube. The joints are achieved by means of a crimping tool. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Aquaflow polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Range of Kelox Protec brass & PPSU push fit connection fittings with EPDM seal rings for use with Kelox multilayer composite pipe (PE-RT type ll/AL/PE-RT type ll). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of polypropylene push-fit fittings and inserts for use with MDPE pipe (manufactured to BS EN 12201). For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of polypropylene push-fit fittings with inserts for use with MDPE Pipe (manufactured to BS EN 12201-2) on one side of the fitting and PB (BS 7291), PEX (BS 7291) or Copper (BS EN 1057) on the other. Models UTS147-DB, UTS197-DB & UTS251-DB are for above and below ground use. All other models are for above ground use only. Maximum working pressure when using 20mm pipe is 16.0 bar. Maximum working pressure when using 25mm & 32mm pipe is 12.5 bar. Cold water use only.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of brass and copper fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 18.6 bar. Maximum operating temperature 100°C.
Page 23 of 201
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.