Range of single flush siphonic WC outlet valves comprising of a plastic body, LDPE diaphragm washer and stainless steel C link. Cold water use only.
Dual flush, WC outlet valve operated via a push button assembly for either full or reduced flush. Cold water use only
Dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.
Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.
Water meter incorporating a brass inner body, a plastic outer body and liquid silicone ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of concealed bathroom boxes with extractable shower hoses. The inlet attached to the concealed box incorporates an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the shower hose also includes a stainless steel strainer. Maximum operating temperature 60°C.
Range of pressure transmitters with stainless steel bodies. Maximum working pressures: DST-P140 model 25.0 bar, all other models 50.0 bar. Maximum operating temperature 90°C.
Water hammer arrestor with brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of 2,3 or 4 way manifolds incorporating a nickel plated brass body with non-rising spindle stop valves. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Intelligent water assist valve consisting of a motorised quarter turn shut off valve which operates in the event a leak on the supply pipe to which it is fitted. Maximum working pressure 10 bar. Cold water use only.
Range of circulating pumps, with plastic or stainless steel bodies (cast EN 1.4308 or plate EN 1.4301) and a plastic impeller. Maximum working pressure 10.0 bar (stainless steel bodied pumps), 3.0 bar (plastic bodied pumps). Maximum operating temperature 95°C.
Range of single stage circulating pumps with plastic impellers and stainless steel housing, (red or black external coating, and from July 2023 a yellow external coating on the 1½" model with 130mm port length). From December 2023 the UPS25 prefix models can be supplied with EPDM inlet/outlet gaskets and the UPS32 prefix models can be supplied with fibre/NBR inlet/outlet gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C (s/steel plate EN 1.4301/1.4401 models) or 99°C (s/steel cast EN 1.4308 models).
Range of single stage centrifugal pumps with bronze housings or plastic housings (see model) and plastic impellers. Maximum working pressure 6.0 bar (UP(S)(O) 15-XX CES87 130 model only), 10.0 bar (all other models). Maximum operating temperature 95°C.
MBC 12-22WM & MBC 12-28WM models are wall mounted mains supply booster sets. They are supplied with two spherical isolation valves, a spherical bypass valve and two single check valve assemblies (suitable for backflow protection against Fluid Category 2). The check valve assemblies are to be installed in accordance with the manufacturers instructions, one upstream of the pump inlet and one after the bypass valve. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet and is housed within a wall mounted cabinet. MJ3 VM & MJ3 HM models are mains supply booster sets intended to be mounted on an expansion vessel (not supplied as part of the approval). They comprise of a pump, a suction and discharge manifold with bypass arrangement, and a spherical bypass valve which incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet. Maximum working pressure 6.0 bar. Cold water use only.
Multistage, vertical booster pumps with a brass body and stainless steel pump housing, stainless steel impellers and EPDM ‘O’-rings. The 41782 (MV90 4M VSD) model includes a pressure transducer. Maximum working pressure 6.0 bar. Cold water use only.
Range of wall mounted handshower, hose and elbow sets with metal bodies (various finishes), incorporating an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Handsets incorporate an approved check valve cartridge , however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Page 23 of 205
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.