Range of PVC or EPDM lined shower hoses with stainless steel outer (chrome or black finish) or PVC reinforced (chrome plated finish) outer layer. Maximum operating temperature 65°C.
Range of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The secondary circuit consists of a temperature and pressure relief valve set at 10.0 bar and 90°C and an alternative temperature and pressure relief valve also set at 10.0 bar and 90°C , an inlet control group consisting of a pressure reducing valve pre-set at 3.0 bar, an expansion relief valve set at 8.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum working pressure - Primary circuit: 6.0 bar & Secondary circuit: 7.5 bar Maximum operating temperature 85.0°C
Concealed electronic thermostatic shower valve with a plastic body, the flow is controlled via two motorised valves for hot and cold supply. Both inlets incorporate a plastic strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The valve can be supplied with a variation of shower kits that can consist of the following components: handsets, overhead showers, shower hoses, wall outlets, fixed arms, and isolation valves. Maximum working pressure 7 bar. Maximum working temperature 65°C.
Concealed electronic thermostatic shower valve with a plastic body, the flow is controlled via two motorised valves for hot and cold supply. Both inlets incorporate a plastic strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. This product is also supplied with a concealed diverter valves with a plastic body. The flow is controlled to two outlets via solenoid valves. The valve can be supplied with a variation of shower kits that can consist of the following components: handsets, overhead showers, shower hoses, wall outlets, fixed arms, and isolation valves. Maximum working pressure 5.0 bar. Maximum working temperature 65°C.
Electronically controlled thermostatic shower mixing valve with a plastic body. Temperature is controlled via two motorised valves and a thermistor. The product also incorporates a pump and plastic filters on each inlet. The valve can be supplied with a variation of shower kits that can consist of the following components: handsets, overhead showers, shower hoses, wall outlets, fixed arms, exposed elbows and isolation valves. Maximum working pressure 7.0 bar. Maximum working temperature 65°C.
Electronically controlled thermostatic shower mixing valve with a plastic body. Temperature is controlled via two motorised valves and a thermistor. The product also incorporates a pump and plastic filters on each inlet. This product is also supplied with a concealed diverter valves with a plastic body. The flow is controlled to two outlets via solenoid valves. The valve can be supplied with a variation of shower kits that can consist of the following components: handsets, overhead showers, shower hoses, wall outlets, fixed arms, exposed elbows, and isolation valves. Maximum working pressure 5.0 bar. Maximum working temperature 65°C.
Range of adjustable or pre-set T-type thermostatic blending valves with brushed chromium plated DZR brass bodies. Supplied with an olive and compression nut. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of wall mounted, concealed thermostatic blending valves or exposed bar type thermostatic blending valves (chromium plated brass) incorporating a 2-way manual diverter valve controlling and diverting the flow between an overhead shower and a shower outlet with dome type operating members. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button incorporate. An approved check valve cartridge is also supplied, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with a shower head, shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C (F4017x & F2167x models. All other models 60°C only).
Range of wall mounted thermostatic blending valves (chrome plated brass), incorporating a quarter turn ceramic disc, half turn ceramic disc or ceramic cartridge headworks (see models). The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button, with a variety of operating members. The inlets incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection with stainless-steel strainers. Maximum working pressure 5.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of thermostatic shower panels incorporating a single sequential thermostatic control valve with a single lever operating member and flexible riser kit. Each inlet supplied with a servicing valve, EPDM o-ring and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with black lined PVC shower hoses and chrome plated shower handsets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Page 204 of 320
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.