#2208817

Range of end feed copper fittings for use with copper tube to EN 1057. The 950513, 950514, 950501, 950503 & 950502 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1210 Fittings for use with Tube and Pipe
Section Subtitle:
End feed, for use with copper tube. Unless specified in the individual approval, the products within this section are not suitable for below ground use
WRAS Approval Number:
2208817
Size:
End feed: 8mm-108mm and ½” - 1” (see model). Threaded connections: ½”-2” BSP (M)/(F) and 1” captive nut (see model).
Marking:
CPS & date of manufacture MM/YY on body.
Installation Requirements:
R001
Expiry date:
31/08/2027
Model:
237738, 237770, 950504, 950505, 950506, 950507, 950508, 950509, 953104 & 953105 Elbow 90 degree C X C: 8mm-108mm. 237740, 237769, 501657, 950510, 950511, 950512, 954699 & 954700 Street Elbow 90 degree Ftg X C: 8mm-108mm. 501643, 501764, 577336, 858891, 858892 & 858893 Street Elbow 45 degree Ftg X C: 8mm-108mm. 952608, 952609, 952610, 954695, 954696, 954697, 237739 & 237743 Elbow 45 degree C X C: 8mm-108mm. 954750 & 954751 Partial Crossover Ftg x C: 12mm-28mm. 954668, 954669 & 954670 Slip Straight Coupling C X C: 8mm-108mm. 237772, 237773, 950489, 950490, 950491, 950492, 950493, 950494, 953091, 953092 & 954675 Straight Coupling with groove C X C: 8mm-108mm. 237741, 799352, 950495, 950496, 953097, 953098, 954678, 954679, 954680, 954681, 954682, 954683, 954684, 954685, 954686, 954687, 954688, 954689, 954690, 908683, 908706 Fitting Reducer Ftg X C: 8mm-108mm. 950497, 953093, 953094, 953095, 953096, 953172 & 954691 Reducing Coupler C X C: 8mm-108mm and ½” - 1”. 237733, 237736, 950515, 950516, 950521, 950528, 950529, 953111, 953112 & 954713 Equal TEE CxCxC: 8mm-108mm. 237767,496119, 689717, 813643, 950517, 950518, 950519, 950520, 950522, 950523, 950526, 950527, 953169, 954717, 954719, 954720, 954721, 954722, 954723, 954724, 954727, 954728, 954729, 954730, 954732, 954733, 954734, 954735 & 954736 Reducing Tee CxCxC: 8mm-108mm. 237735, 237742, 945648, 950531, 952561, 953113, 953114, 954738, 954739 & 954740 Cap: 8mm-108mm. 953117 & 954749 Full Crossover C x C: 12mm-28mm. 909039 & 909054 Female Adapter C X C: 15mm x ½” NPT (F) - 54mm x 2” NPT (F). 952367 Return Bend Stop: 15mm-54mm. 909065, 909104, 950546 & 954776 Male Adapter C X C: 15mm x ½” NPT (M) - 54mm x 2” NPT (M). 954710 BENT CYLINDER UNION: 22mm x 1” captive nut and 28mm x 1” captive nut. 954745 & 954746 STRAIGHT CYLINDER UNION: 22mm x 1” captive nut and 28mm x 1” captive nut. 950513 & 950514 Bent Nut Connect C x Fi: 15mm x ½” captive nut - 22mm x ¾” captive nut. 950501, 950503 & 950502 Straight Nut Connect C x Fi: 15mm x ½” captive nut - 22mm x ¾” captive nut.

Approval Holder:
The Highbourne Group, City Plumbing Supplies
Company Name
The Highbourne Group, City Plumbing Supplies
Address
Branch Support Centre Highbourne House Highbourne House Crick Northampton
Postcode
NN6 7SL
Country
United Kingdom
Phone
07342 078865
General Email
Lindsey.cocks-stevens@cityplumbing.co.uk

View All Listings by this Company

Print This Approval


#2111389

Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C

Section:
1390 Heaters
Section Subtitle:
Electric, thermal storage, mains fed, open outlet.
WRAS Approval Number:
2111389
Size:
3/8” BSP
Marking:
INTU on front of machine Model and other tech info on adhesive label on body
Installation Requirements:
R001
Expiry date:
30/11/2026
Model:
2.4L,1500KW: SOLO ,LUXE, NEW SOLO & NEXUS 4L,2300KW: NEXUS PRO

Approval Holder:
INTU K Limited
Company Name
INTU K Limited
Address
Unit 6 BRK Enterprise Business Park, Runshaw Lane, Euxton
Postcode
PR7 6HD
Country
United Kingdom

View All Listings by this Company

Print This Approval


#2207350

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207350
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
Ideal heating printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2027
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
Logic Max Combi² C24 – UIN 228334, Logic Max Combi² C30 – UIN 228335, Logic Max Combi² C35 – UIN 228336, Logic + Combi² C24 – UIN 228329, Logic + Combi² C30 – UIN 228330, Logic + Combi² C35 – UIN 228331, Logic Combi² C24 – UIN 228307, Logic Combi² C30 – UIN 228308, Logic Combi² C35 – UIN 228309.

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company
Manufacturer:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company

Print This Approval


#2209322

Brass fitting Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1478 Heater
Section Subtitle:
Combination boilers - accessories and components.
WRAS Approval Number:
2209322
Size:
10mm spigot (F) x 10mm spigot (M).
Marking:
Navien on body.
Installation Requirements:
R001
Expiry date:
30/09/2027
Model:
LL1466-04-09 Connector.

Approval Holder:
KD Navien
Company Name
KD Navien
Address
95, Suworam-gil Seotan-myeon Pyeongtaek-si Gyeonggi-do, Seoul
Country
Korea, Republic of

View All Listings by this Company
Manufacturer:
Zhejiang Double-Lin Valves Co. Ltd.
Company Name
Zhejiang Double-Lin Valves Co. Ltd.
Address
Yanpan Hardware Industrial Area, Ganjiang Town, Yuhuan
Country
China
Phone
+86-576-89915157

View All Listings by this Company

Print This Approval


#2209020

Biofilm and water quality monitor incorporating a stainless-steel body and silicon seals. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2209020
Note:
The monitor has been judged only against the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009 and has not been checked for accuracy by the Scheme.
Size:
¾” female BSP inlet x ¾” male BSP outlet.
Marking:
Sol, Model and product information on adhesive label on side of casing.
Installation Requirements:
R001
Expiry date:
30/09/2027
Model:
Solution MX1

Approval Holder:
Waterman Environmental Group
Company Name
Waterman Environmental Group
Address
SOLmicroTEK Ltd., Cotswold Business Centre, 2, AP Ellis Road, Upper Rissington, Gloucestershire
Postcode
GL54 2QB

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 190 of 890

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.