Range of plate heat exchangers with pressed stainless steel plate bodies and copper brazing. Available with threaded or flat face seal connection (see model). Maximum working pressure varies by model: ZT190 & ZT207 - 8.0 bar; ZB190, ZB195, ZB200, ZB207 & ZB315 - 10.0 bar; ZC315 (flat face seal version only) - 16.0 bar; ZC190, ZC207, ZC315 (threaded only) & Z(B-C-E) 250, 400, 450, 500 – 30.0 bar or 45.0 bar (models with additional upper and lower plates only); ZB600 & ZB700 - 30.0 bar. Maximum operating temperature 99°C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel filter. The primary and secondary circuit incorporates isolation valves on the flow and the primary also has one on the return. Maximum working pressures: Secondary DHW: 10.0 Bar Primary CH: 2.5 Bar Maximum operating temperatures: Secondary DHW: 65.0°C Primary CH: 85.0°C
CZ4000 range of in-line water meters with polyamide bodies and EPDM rubber `O` rings. The meters incorporate a plastic strainer. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 50°C
Water meter manifold assembly with gunmetal body, incorporating a servicing valve and a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Max operating pressure 16 bar Maximum operating temperature Cold water only
Range of water meter housings. The 4414-WMH-20 (threaded) model has a DZR brass body and a check valve cartridge on the inlet verified by test (suitable for backflow protection against Fluid Category 2). The 4414-WMH-1 & 4414-WMH-2 (compression) models have a brass body and an approved check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection. The compression models are for use with copper pipe (manufactured to EN 1057). Maximum operating pressure 16.0 bar. Maximum operating temperature 85°C.
Range of flow sensors with plastic bodies and rotors. Maximum working pressure: 10 Bar. Maximum operating temperature: 80°C.
Range of ancillary inlet connections with brass bodies (various finishes, see models). Model PSH036 is deck mounted. Models PSH039 & PSH045 are wall mounted. Maximum working pressure: 5 bar. Maximum operating temperature: 85°C.
Range of ancillary connections with brass bodies (various finishes). Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
‘SCALA 2’ integrated, self-priming, plastic bodied (compact) mains pressure boosting pump. Maximum working pressure 10.0 bar. Cold water use only.
`UPM3` range of single stage circulator pumps, with stainless steel or plastic bodies, plastic impellers, ceramic shafts and bearings, EPDM 'O'-rings and seals. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of hand showers (various finishes). Maximum operating temperature 65°C
Range of medical shower handsets incorporating plastic bodies and EPDM O-rings with various inserts. Supplied with PVC/PEX lined shower hoses incorporating EPDM washers. Maximum operating temperature 65°C. Open outlet use only
Range of wall mounted shower outlets with chromium plated brass body. The product incorporates a stainless steel strainer, plastic flow regulator and an approved single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature 65.0°C.
Range of shower arms, hand shower holders and wall outlet with brass bodies (various finishes). Maximum working pressure: Open outlet. Maximum operating temperature: 60°C.
Range of shower panel units incorporating an overhead shower outlet. Flow is controlled via spring-loaded headworks using a push-button mechanism. The shower outlet connection incorporates an approved single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of shower handsets with either a white or chrome plated plastic body. Maximum operating temperature 45°C.
Range of shower arms and ceiling connectors (brass bodies – various finishes) & overhead shower outlets (plastic bodies - various finishes), incorporating EPDM O rings, plastic flow regulators and stainless-steel strainers. Open outlet use only Maximum operating temperature 60.0°C
Range of shower arms and ceiling connectors (brass bodies – various finishes) & overhead shower outlets (plastic bodies - various finishes), incorporating EPDM O rings, plastic flow regulators and stainless-steel strainers. Open outlet use only. Maximum operating temperature 60.0°C
Range of shower riser kits and shower cradle kits. Models PSA006, PSA013, PSA007, PSA012, PSA002, PSA004, also incorporate a manual operated diverter with single lever operating member. Maximum operating temperature 65.0°C
Range of shower outlets comprising of shower handsets (brass bodies – various finishes) and overhead showers (stainless-steel bodies – various finishes), incorporating stainless-steel strainer washer. Model (CPH05013) incorporates a flow limiter in the inlet. Maximum operating temperature 85°C.
Page 187 of 311
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.