Directory Search Results

Print List

#2212116

Concealed WC dual flushing cistern with a bottom entry BS 1212 - 4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar, cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2212116
Size:
½” BSP (M)
Marking:
Model, WRAS & C.P HART on front cover 6 Litre inside of cistern.
Installation Requirements:
R001 R280 R556 R560 R571 R581
Expiry date:
31/12/2027
Model:
CPHF1135 (500mm) with frame CPHSCON (500mm) without frame

Approval Holder:
C.P.Hart
Company Name
C.P.Hart
Address
Unit 40 Charles Park Claire Causeways Crossways Business Park Dartford
Postcode
DA2 6QA
Country
United Kingdom
General Email
roy.davis@cphart.co.uk

View All Listings by this Company

Print This Approval


#2306091

Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2306091
Size:
½” BSP (M)
Marking:
Model, WRAS & C.P HART on front cover 6 Litre inside of cistern.
Installation Requirements:
R001 R556 R581
Expiry date:
30/06/2028
Model:
CPHF825 CPHSHCON

Approval Holder:
C.P.Hart
Company Name
C.P.Hart
Address
Unit 40 Charles Park Claire Causeways Crossways Business Park Dartford
Postcode
DA2 6QA
Country
United Kingdom
General Email
roy.davis@cphart.co.uk

View All Listings by this Company

Print This Approval


#241204725

The range of WC cisterns incorporating a BS 1212-4:2016 side entry or bottom entry float operated inlet valve providing a Type AG air gap arrangement and a flush outlet valve operated via a push button assembly for either full or reduced flush. Maximum operating pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
241204725
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M)
Marking:
Geberit etched to flush plate Water line and volume within cistern Geberi, model and other info etchen within cistern on backplate
Installation Requirements:
R001 R280 R556 R581
Expiry date:
31/12/2029
Model:
Geberit Alpha Duofix 82cm, 98cm and 112cm Geberit Alpha Concealed Cisterns 82cm & 109cm
Product Images

Approval Holder:
Geberit Sales Ltd.
Company Name
Geberit Sales Ltd.
Address
Geberit House, Edgehill Drive, Warwick
Postcode
CV34 6NH
Country
United Kingdom
Phone
01926516800
General Email
enquiries@geberit.co.uk

View All Listings by this Company

Print This Approval


#250104711

DC type pipe interrupter with a permanent atmospheric vent (DZR brass body) incorporating a flow regulator at the inlet and brass shroud. Maximum working pressure 6.0 bar. Cold water use only.

Section:
0014 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2. Type DC - Pipe interrupter with permanent atmosphere vent. The device must be fitted with the lowest point of the air aperture not less than 150mm above the free discharge point, or spillover level of an appliance, and have no valve, flow restrictor or tap on its outlet.
WRAS Approval Number:
250104711
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” BSP (F)
Marking:
Cistermiser on shroud, DC pipe interrupter and CR mark stamped on body.
Installation Requirements:
R001 R165
Expiry date:
31/01/2030
Model:
DWC/10
Product Images

Approval Holder:
Cistermiser Ltd
Company Name
Cistermiser Ltd
Address
Unit 1 Woodley Park Estate, 59/69 Reading Road Woodley
Postcode
RG5 3AN
Country
United Kingdom
General Email
jake.felstead@cistermiser.co.uk

View All Listings by this Company

Print This Approval


#241204709

Range of spring loaded, resilient trim check valve cartridges with plastic body. For insertion into fittings with specifically sized bores. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.

Section:
0026 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Check Valve Cartridge. The cartridges listed in this section are for factory installation only and are not suitable for on-site installation.
WRAS Approval Number:
241204709
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DN15, DN20 & DN25.
Marking:
W (Watts logo – Socla is a unit of the Watts Group), DN & flow arrow on body. Models WM020 & WM025 also have Ocean on body.
Installation Requirements:
R001
Expiry date:
31/12/2029
Model:
Type TK range: Model WM015 (Ref W149015600 or 149B043318): DN15. Model WM020 (Ref W140020600 or 149F043509): DN20. Model WM025 (Ref W140025600 or 149F043510): DN25.
Product Images

Approval Holder:
Socla SAS
Company Name
Socla SAS
Address
365, Rue du Lt Putier, 71530 Virey Le Grand, France
Phone
+33 3 85 97 42 42

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1415 of 1715

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.