Elisa Range of multi-layer shower hoses with a PVC inner hose, supplied with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of stainless steel interlocked (H35 models) or nylon braided (H36 models) flexible hose assemblies. H35 models are available with either a silicone or TPE liner, the H36 models are available with a TPE liner only. Maximum operating temperature 60°C.
Range of stainless steel or nylon braided, PEX or EPDM inner liner flexible hose assemblies available in a range of various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel or nylon braided, thermoplastic silicone rubber (TPSiV) lined flexible hoses with a variety of end connectors. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Centerstore ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Range of CENTERSTORE AIR bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added March 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar. Maximum operating temperature 65°C.
Range of wall mounted thermostatic shower valves (various finishes) incorporating a quarter turn ceramic disc headworks with single lever type operating members. The temperature is controlled independently via a thermostatic cartridge with manual override and single lever type operating members. Both inlets incorporate approved single check valve cartridges (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Wall mounted, exposed, thermostatic shower mixing valve (chromium plated brass). The product incorporate a ¼ turn ceramic disc or a 2-way ceramic disc diverter headwork (see model). Temperature is controlled independently via a thermostatic cartridge with a manual override button. The product has a dome type operating member. Each inlet incorporates a combined EPDM washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Wall mounted, bar type, thermostatic shower mixer (chromium plated brass), incorporating a 2-way ceramic disc diverter headwork with a dome type operating member controlling the flow between each shower outlet. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The product is supplied with a shower hose (metal interlocked), shower handset (chrome plated), riser rail and overhead shower. The shower handset and the overhead shower both incorporate a stainless-steel strainer on the inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic shower mixing valves (chromium plated brass). The products incorporate a ¼ turn ceramic disc or a 2-way ceramic disc diverter headwork (see model). Temperature is controlled independently via a thermostatic cartridge with a manual override button. All models have cube operating members except model 706128 which has dome operating member. Each inlet incorporates a combined EPDM washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Wall mounted thermostatic blending valve (chromium plated brass). Temperature is controlled via a thermostatic cartridge with a cube operating member incorporating a manual override and the flow is controlled via two push type cartridges for the shower outlets. The inlets incorporate stainless steel strainers and approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic shower valves with brass bodies (various finishes), incorporating a thermostatic cartridge controlling the temperature and a push shut-off valve controlling the flow. The inlets and the shower outlet incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Wall mounted, manually operated blending valve with a brass body (various finishes) and ceramic cartridge headwork a single lever operating member. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Wall mounted, manual blending valve (brass body, various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. This product is not claimed to provide any backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed (BIV & BIR models) and exposed (EV model) thermostatic shower control valves. The bodies are cast brass (concealed versions) with a chromium plated trim set or chromium plated brass (exposed versions). Flow and temperature are controlled by a thermostatic cartridge with a single lever operating member. The inlets incorpoarate stainless steel strainers. Some models are supplied with a shower hose and handset or an overhead shower arm and shower head with flow regulator (see model section). The BIV model is also supplied with an angled wall outlet elbow. Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Range of lugged and wafer type butterfly valves with blue epoxy coated bodies, incorporating EPDM rubber ‘O’-rings and seat, and either a bronze (AB2), stainless steel (CF8 & CF8M) or blue epoxy coated or nickel plated, ductile iron (DI) disc. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of wafer and lug type butterfly valves incorporating blue epoxy coated ductile iron bodies, either stainless steel (SS316/SS304) or epoxy coated ductile iron discs and EPDM seat. The valves are either handwheel and gear operated (Models SD-BVG16 and SD-16BVLL) or lever operated (Models SD-BVL125 and SD-16BVGL). Maximum working pressure 16.0 bar Maximum operating temperature 85°C.
Range of concealed manual diverters (brass bodies) with chrome trim sets, model RAKPES3020-1C incorporating a dome type operating member and model RAKPER3020-1C incorporating a single lever operating member. Maximum working pressure – 5.0 Bar Maximum operating temperature - 85 °C
Range of inline manually adjustable pressure reducing valves with DZR brass or bronze bodies (see model), EPDM diaphragm, seat washers and ‘O’-rings. Adjustable outlet pressures between 1.0 and 7.0 bar. Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass, gunmetal or stainless-steel bodies. Maximum inlet pressure for HP and SP Models = 25.0 bar. Maximum inlet pressure for LP Models = 6.0 bar. Between September 2022 and December 2023, the maximum operating temperature of models included on the approval was 60°C. From January 2024, the maximum operating temperature of those models increased to 85°C. Models added to the approval in January 2024: Models with maximum working pressure of 6.0 & 16.0 bar models are for cold water use. Models with maximum working pressure of 25.0 bar have a maximum operating temperature of 85°C.
Page 128 of 394
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.