Range of multi-layer shower hoses with a PVC inner hose, supplied with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of “Tempest” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.
Whitewolf Alpha ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Elite ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Flowcyl ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Nucyl ranges of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Range of air venting valves incorporating an epoxy coated, iron body and a drain point. Maximum working pressure 16.0 bar. Maximum operating temperature 60˚C.
Range of air venting valves with a blue epoxy coated ductile iron body and carbon steel cover, NBR ‘O’-rings and EPDM seals. Maximum working pressure 10.0 bar or 16.0 bar (see model). Maximum operating temperature 65°C.
Range of air venting valves incorporating an epoxy coated, iron body and a drain point. Maximum working pressure 16.0 bar. Maximum operating temperature 60˚C.
Range of wall mounted, concealed, manual blending valves with either a dome type or single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Range of wall mounted, concealed, manually operated blending valves with brass bodies (various finish trim kits - see model) incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, manually operated, concealed blending valve with a brass body incorporating a ceramic cartridge headwork with a single lever operating member controlling both flow and temperature. Maximum working pressure 5.0 bar. Maximum operating temperature 90°C.
Wall mounted manually operated, concealed blending valve (brass body) incorporating a ceramic cartridge headwork controlling both flow and temperature with single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Wall mounted thermostatic bar type shower valve incorporating a ceramic cartridge headwork, with single lever operating member, which controls and diverts the flow between the two shower outlets. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member which incorporates a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower valves, riser rail, shower handset, shower hose and overhead shower outlet. The valve incorporates a brass body (various finishes) and ceramic disc headwork with dome type operating member which controls and diverts the flow between the two shower outlets. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Inlets incorporate stainless steel filters and a single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic bar type shower mixing valves (chromium plated brass). The F061 & 081 prefix models incorporate a 2-way ceramic disc diverter headwork with dome (F06 prefix models) or cubed type (F08 prefix models) operating members controlling the flow either shower outlet. The F062 & 082 prefix models incorporate a ¼ turn ceramic disc headwork with dome (F06 prefix models) or cubed type (F08 prefix models) operating members controlling the flow to a single shower outlet. The temperature is controlled independently via a thermostatic cartridge. The inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Wall mounted, exposed, thermostatic bar type shower mixing valve (chromium plated brass) incorporating a 2-way ceramic disc diverter headwork with a dome type operating member, which diverts the flow between outlets. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a combined NBR washer and stainless steel strainer and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
‘Ausimix’ compact range of ‘T’-type thermostatic blending valves with nickel plated DZR brass bodies. Each inlet incorporates a stainless-steel strainer and a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The SBHEAT110780, SBHEAT110785, HEAT110780 & HEAT110785 models also have angled isolation valves at both inlets. Maximum working pressures and operating temperatures: Existing push fit models: For use with PEX pipe (manufactured to BS7291 part 3) and Polybutylene pipe (manufactured to BS7291 part 2): 12.0 bar, cold water use only. 6.0 bar @ 95°C. For use with copper pipe: Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. Compression models added October 2023: For use with copper pipe to BSEN1057:2006: Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, thermostatic, shower mixers incorporating brass bodies (various finishes) 2-way ceramic disc diverter headwork to control the flow between two shower outlets with various operating members (see model). The A47203VUK model uses two ‘detent’ (push to on push to off) headworks to control the flow to each outlet. Temperature is controlled independently via a thermostatic cartridge using various operating members (see model) that also incorporates a manual override button. The inlets incorporate a combined EPDM washer and stainless-steel strainer or stainless steel strainer (A47203VUK model) and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower incorporates a combined EPDM washer and stainless-steel strainer. The products are supplied with a shower head, shower hose and handset. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Flow control valve incorporating a ceramic cartridge headwork fitted within a chrome plated brass body and a single lever operating member. Product is supplied with a Stainless steel braided PEX lined hose assembly that connects to the outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Page 13 of 56
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.