Directory Search Results

Print List

#2007700

Range of WC dual flush drop valves with an ABS body and silicon seal. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal adjustable height overflow. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2007700
Size:
1 ½” and 2” BSP (M) outlet.
Marking:
Macdee, Wirquin, Model & WRAS on Top of Flush Valve
Installation Requirements:
R001 R556 R571
Expiry date:
31/07/2025
Model:
AFV50100 – KAYLA & AFV50200 – KAYLA

Approval Holder:
Wirquin Ltd
Company Name
Wirquin Ltd
Address
Unit 3 Alpha Court Thorne Doncaster
Postcode
DN8 5TZ
Country
United Kingdom
Phone
01302 312252
General Email
mick.kirby@wirquin.co.uk

View All Listings by this Company
Manufacturer:
Wirquin Ltd
Company Name
Wirquin Ltd
Address
Unit 3 Alpha Court Thorne Doncaster
Postcode
DN8 5TZ
Country
United Kingdom
Phone
01302 312252
General Email
mick.kirby@wirquin.co.uk

View All Listings by this Company

Print This Approval


#2005352

Range of commercial glass washing machines with flow controlled via a solenoid valve. The products are supplied with a dual layer supply hose (Grey PVC outer/Black PVC inner) with ¾” captive nuts at either end and a loose double check valve assembly (suitable for backflow protection against Fluid Category 3) for installation prior to the inlet hose. Maximum working pressure 4.0 Bar. Cold water use only.

Section:
1310 Glass/Bottle Washers
Size:
¾” BSP (F) (to the supply hose)
Marking:
Model, manufacturers name and other technical information on data label on panel.
Installation Requirements:
R001 R009
Expiry date:
31/05/2025
Proviso:
Discharge to drain must be via a type `AA`, `AB` or `AD` airgap, or in accordance with EN1717. No detergents are to be used with these appliances that represent a Fluid Category risk that is greater than that provided by the dedicated backflow prevention device or arrangement upstream of the appliance. If this cannot be determined IRN R090 applies.
Model:
ASBER - GRAND EASY Range (electromechanical control glass-washers): GE-350 UK (*SA). GE-350 B UK (*SA). GE-350 DD UK (*SA). GE-350 B DD UK (*SA). GE-400 UK (*SA). GE-400 B UK (*SA). GE-400 DD UK (*SA). GE-400 B DD UK (*SA). ASBER - GRAND MITTE Range (electronic control glass-washers): GM-350 UK (*SA). GM-350 B UK (*SA). GM-350 DD UK (*SA). GM-350 B DD UK (*SA). GM-400 UK (*SA). GM-400 B UK (*SA). GM-400 DD UK (*SA). GM-400 B DD UK (*SA). ASBER - GRAND TECH Range (electronic control and temperature display glass-washers): GT-350 UK (*SA). GT-350 B UK (*SA). GT-350 DD UK (*SA). GT-350 B DD UK (*SA). GT-400 UK (*SA). GT-400 B UK (*SA). GT-400 DD UK (*SA). GT-400 B DD UK (*SA). AQUATEC - AQUATEC Range (electromechanical control glass-washers): AQUATEC G40DPN B DD UK Where 350 or 400 in the model code denotes baskets size, e.g. 350x350mm or 400x400mm. B = drain pump. DD = detergent doser. UK = English electrical plug. SA = stainless steel washing and rinse arms.

Approval Holder:
ONNERA POLAND Sp. z.o.o.
Company Name
ONNERA POLAND Sp. z.o.o.
Address
Palmiry Ul Warszawska 9 05-152
Country
Czosnow

View All Listings by this Company
Manufacturer:
ONNERA POLAND Sp. z.o.o.
Company Name
ONNERA POLAND Sp. z.o.o.
Address
Palmiry Ul Warszawska 9 05-152
Country
Czosnow

View All Listings by this Company

Print This Approval


#2005009

Copper plate heat exchanger with copper connections, incorporating 72 fins. Maximum working pressure Heating circuit 3.0 bar, Sanitary circuit 8.0 bar Maximum operating temperature 99°C

Section:
1350 Heat Exchangers
Size:
18mm female spigot on sanitary circuit 22mm female spigot on heating circuit
Marking:
VALMEX, model number, date of manufacture (WW/YYYY) and other technical information on adhesive label.
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2025
Model:
COMPACT BITHERMIC HEAT EXCHANGER – 6T OV 26.6X13.6 B225 72 FINS IM WITH COPPER CONNECTIONS.

Print This Approval


#2006008

An in-line ultra-sonic water meter with brass or plastic bodies (see model). Maximum working pressure 16.0 bar. Maximum operating temperature 70°C.

Section:
1505 Water Meters
Size:
¾” BSP (M) inlet and outlet
Marking:
Sagemcom and flow arrow on body. Marking added June 2021: Sagemcom, CE, DN, max temperature and other technical information on meter face.
Installation Requirements:
R001
Expiry date:
30/06/2025
Model:
Model WM 15: Siconia Water Meter Brass DN15 Model added June 2021: Model SM 15 PL110: Siconia Water Meter plastic Model WM15: Siconia Water Meter plastic DN15

Approval Holder:
Sagemcom Energy & Telecom
Company Name
Sagemcom Energy & Telecom

View All Listings by this Company

Print This Approval


#2006025

Range of water meters with black nylon bodies and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1505 Water Meters
Size:
1 ½” BSP (M)
Marking:
Arad on dial face.
Installation Requirements:
R001
Expiry date:
30/06/2025
Model:
'PD ½’’ concentric plastic with raiser & PD ¾’’ concentric plastic with raiser'.

Approval Holder:
Arad GROUP Ltd.
Company Name
Arad GROUP Ltd.
Address
Kibbutz Dalia 1923900 Kibutzz Dalia
Country
Israel
Phone
+972-4-9897906
General Email
Dars@arad.co.il

View All Listings by this Company
Manufacturer:
Arad GROUP Ltd.
Company Name
Arad GROUP Ltd.
Address
Kibbutz Dalia 1923900 Kibutzz Dalia
Country
Israel
Phone
+972-4-9897906
General Email
Dars@arad.co.il

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 12 of 2215

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.