Directory Search Results

Print List

#240602718

Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
240602718
Size:
½” BSP (M)
Marking:
BAGNODESIGN and model name on cover, 6 litre line inside cistern
Installation Requirements:
R001 R280 R556 R581
Expiry date:
30/06/2029
Model:
BDS-B695-D13-ESG1 concealed WC flushing cistern

Approval Holder:
BAGNODESIGN
Company Name
BAGNODESIGN
Address
UNIT 1 OAKWELL PARK TRADING ESTATE BIRSTALL
Postcode
WF17 9LU

View All Listings by this Company

Print This Approval


#2012118

WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2012118
Size:
½” BSP (M)
Marking:
BAGNODESIGN and model number on cistern body. 6 litre line inside cistern
Installation Requirements:
R001 R556
Expiry date:
31/12/2025
Model:
BDS-K301-A01-ESG6 UNIVERSAL FRAME 1140 SLIM CONCEALED CISTERN FOR WALL HUNG WC BDS-K301-D01-ESG4 CONCEALED CISTERN FOR BACK TO WALL WC

Approval Holder:
BAGNODESIGN
Company Name
BAGNODESIGN
Address
UNIT 1 OAKWELL PARK TRADING ESTATE BIRSTALL
Postcode
WF17 9LU

View All Listings by this Company

Print This Approval


#2012119

WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2012119
Size:
½” BSP (M)
Marking:
BAGNODESIGN and model number on cistern. 6 litre line inside cistern
Installation Requirements:
R001 R556
Expiry date:
31/12/2025
Model:
BDS-K133-A01-ESG6 UNIVERAL FRAMED 1120 CONCEALED CISTERN FOR WALL HUNG WC

Approval Holder:
BAGNODESIGN
Company Name
BAGNODESIGN
Address
UNIT 1 OAKWELL PARK TRADING ESTATE BIRSTALL
Postcode
WF17 9LU

View All Listings by this Company

Print This Approval


#2012120

WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2012120
Size:
½” BSP (M)
Marking:
BAGNODESIGN and model number on cistern body. 6 litre line inside cistern
Installation Requirements:
R001 R556
Expiry date:
31/12/2025
Model:
BDS-K210-A01-ESG6 UNIVERAL FRAMED 820 CONCEALED CISTERN FOR WALL HUNG WC BDS-K210-D03-ESG3 CONCEALED CISTERN FOR BACK TO WALL WC

Approval Holder:
BAGNODESIGN
Company Name
BAGNODESIGN
Address
UNIT 1 OAKWELL PARK TRADING ESTATE BIRSTALL
Postcode
WF17 9LU

View All Listings by this Company

Print This Approval


#250201703

Concealed BS EN 14055: 2018 WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. The supply hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2034 Cistern - Flushing
Section Subtitle:
Incorporating Type AB air gap, providing fluid category 5 backflow protection. Suitable for use in a WC suite.
WRAS Approval Number:
250201703
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP Male or 15mm Push-fit Inlet connection.
Marking:
Front service cover is marked with Dudley logo moulding Top of outlet drop valve marked TD Front nut of inlet valve marked DUDLEY
Installation Requirements:
R001 R574 R581
Expiry date:
31/01/2030
Model:
Vantage Concealed Cistern (Category 5).

Approval Holder:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company
Manufacturer:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company

Print This Approval


#250102025

Wall mounted two hole, single outlet (fixed) combination tap assembly with chromium plated brass body. Incorporating a ceramic cartridge headworks with a single lever operating member and a self-cancelling diverter to a shower outlet with a Type HC backflow protection device (verified by test - suitable for backflow protection against Fluid Category 3) The spout outlet incorporates a plastic aerator. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure: 10 Bar. Maximum working temperature: 60°C.

Section:
0554 Combination Tap Assemblies
Section Subtitle:
Two hole tap(s) with a single outlet and a swivel spout, incorporating a self-cancelling diverter to a shower outlet with a Type HC backflow protection device (verified by test - suitable for backflow protection against Fluid Category 3)
WRAS Approval Number:
250102025
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1/2" BSP x 3/4" BSP Offset union
Marking:
Dornbracht on body
Installation Requirements:
R001 R030
Expiry date:
31/01/2030
Model:
33200671
Product Images

Manufacturer:
Dornbracht AG & Co. KG
Company Name
Dornbracht AG & Co. KG
Address
Koebbingser Muehle 6 Iserlohn
Postcode
D-58640
Country
Germany
Phone
+49 2371 433 0

View All Listings by this Company

Print This Approval


#250102714

Range of flow sensors with plastic bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.

Section:
0009 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 - Type AB - Air gap with weir overflow.
WRAS Approval Number:
250102714
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DN6 (½” BSP M), DN8 (½” BSP M), DN10 (¾” BSP M), DN15 (¾” BSP M), DN20, (1” BSP M) & DN25 (1¼” BSP M).
Marking:
Huba control, model code, connection size, date of manufacture (DD/MM/YY) and other technical data on face of body. Flow arrow and DN on body.
Installation Requirements:
R001
Expiry date:
31/01/2030
Model:
Vortex Flow Sensor Type 240.
Product Images

Manufacturer:
Huba Control AG
Company Name
Huba Control AG
Address
Industriestrasse 17, CH-5436 Wurenlos, Switzerland

View All Listings by this Company

Print This Approval


#250104711

DC type pipe interrupter with a permanent atmospheric vent (DZR brass body) incorporating a flow regulator at the inlet and brass shroud. Maximum working pressure 6.0 bar. Cold water use only.

Section:
0014 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2. Type DC - Pipe interrupter with permanent atmosphere vent. The device must be fitted with the lowest point of the air aperture not less than 150mm above the free discharge point, or spillover level of an appliance, and have no valve, flow restrictor or tap on its outlet.
WRAS Approval Number:
250104711
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” BSP (F)
Marking:
Cistermiser on shroud, DC pipe interrupter and CR mark stamped on body.
Installation Requirements:
R001 R165
Expiry date:
31/01/2030
Model:
DWC/10
Product Images

Approval Holder:
Cistermiser Ltd
Company Name
Cistermiser Ltd
Address
Unit 1 Woodley Park Estate, 59/69 Reading Road Woodley
Postcode
RG5 3AN
Country
United Kingdom
General Email
jake.felstead@cistermiser.co.uk

View All Listings by this Company

Print This Approval


#250102709

Spring loaded, resilient trim, in-line check valve cartridge with NBR & EPDM ‘O’-rings, plastic guide, stem and body. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 8.6 Bar. Maximum operating temperature 60°C.

Section:
0026 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Check Valve Cartridge. The cartridges listed in this section are for factory installation only and are not suitable for on-site installation.
WRAS Approval Number:
250102709
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
12.8mm OD
Marking:
SOLEX on body.
Installation Requirements:
R001
Expiry date:
31/01/2030
Model:
T10193
Product Images

Manufacturer:
Xiamen Solex High-Tech Industries Co., Ltd.
Company Name
Xiamen Solex High-Tech Industries Co., Ltd.
Address
No. 298 Yangguang Road West, Haicang District, Xiamen, Fujian Province, 361022
Country
China

View All Listings by this Company

Print This Approval


#250104709

Range of non-verifiable double check valve assemblies, incorporating two spring loaded resilient trim in-line check valve cartridges housed in DZR brass bodies. The products incorporate a drain port between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
250104709
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½”, ¾” & 1” BSP (F)
Marking:
VIR logo, CR, PN16 DN and flow arrow on body.
Installation Requirements:
R001
Expiry date:
31/01/2030
Model:
782DR Double Check Valve
Product Images

Approval Holder:
VIR Valvoindustria Ing. Rizzio S.p.A.
Company Name
VIR Valvoindustria Ing. Rizzio S.p.A.
Address
Via Circonvallazione n. 10, 13018 Valduggia (VC)
Country
Italy

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1045 of 1111

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.