Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a stainless-steel strainer. The primary circuit incorporates isolation valves on the flow and return. Maximum working pressures: DHW: 10.0 Bar CH:2.5 Bar Maximum operating Temperatures: DHW: 65.0°C CH: 85.0°C
Range of flow and temperature sensors with gunmetal bodies and EPDM ‘O’-rings Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of water meters with brass bodies, plastic turbines and EPDM washers. Inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of water meters with brass (CW724R & CC770S) and plastic (Composite) bodies, incorporating plastic strainers and EPDM ‘O’- rings. Maximum working pressure 16.0 Bar. Temperature: 60.0°C for brass (CW724R & CC770S) models & Cold water use only for composite models.
Re-circulation valve with a plastic body and EPDM O-rings. The product is supplied with a pressure relief valve set at 10.0 bar. Supplied with stainless steel braided EPDM line flexible hoses. Compression connection for use with copper pipe manufactured to BS EN1057. Maximum working pressure 9.5 Bar. Maximum operating temperature 82°C
Range of pressure transmitters with stainless steel bodies and an EPDM ‘O’-ring. Maximum working pressures 50.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. CPS models (added February 2024): 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.
Range of temperature measurement devices with bronze bodies and EPDM o-rings. Maximum operating pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
PET braided, PE/EPDM lined ‘Motion hose’, available in a range of lengths. Maximum operating temperature 70°C.
Range of booster pumps with plastic bodies and impellers, stainless steel shafts, brass manifolds, NBR ‘O’-rings and EPDM seals. The product incorporates a pressure vessel. The outlet(s) incorporate(s) an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The inlet hose(s) supplied with this product incorporate(s) an isolation valve. Maximum working pressure 4.0 bar. Maximum operating temperature 65°C.
Page 102 of 229
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.