Range of single hole, single outlet, swivel combination tap assemblies (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The vented models are supplied with a stainless steel braided PEX lined flexible hose assembly incorporating a ½" captive nut end connection, which provides main cold water to a venturi device which is part of a command centre (not supplied). The Arc vented models are supplied with a DZR brass tee piece, two DZR brass adaptors, two stainless-steel strainers (each combined with an EPDM washer) and a plastic flow restrictor, for installation prior to the cold inlet hose. The Arc and Cube mains models are supplied with two DZR brass adaptors and two stainless-steel strainers (each combined with an EPDM washer), for installation on each inlet hose. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range on inline filter cartridges incorporating plastic bodies. The filter media varies between models and includes active carbon, silver impregnated active carbon, silver carbon block & weak/strong cationic resin. Maximum working pressure 6.0 bar. Cold water use only.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes - see model). Electronic controls on the left-hand side of the body allow the tap to dispense one or more of the following (model specification dependent): ambient, near boiling, chilled or sparkling water. The spout incorporates a plastic aerator on the Sparkling/Ambient/Chilled outlet, and a separate outlet for the near boiling water. All models incorporate a vent outlet within the tap spout for the near-boiling water circuit. Near-boiling circuit has a maximum operating temperature of 98°C. All other circuits have a maximum operating temperature of 65°C.
‘G5 C’ command centre providing chilled (filtered) water via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The inlet to the command centre incorporates two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum inlet supply pressure 5.0 bar. Cold water use only.
‘G5 CS’ command centre providing chilled or chilled sparkling water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The product incorporates a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The product is supplied with a filter cartridge. The inlet to the command centre incorporates two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum inlet supply pressure 5.0 bar. Cold water use only.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes - see model). Electronic controls on the left-hand side of the body allow the tap to dispense one or more of the following (model specification dependent): boiling, chilled or sparkling water. Ambient (hot and cold) water is controlled via a ceramic cartridge headwork with a single lever operating member. The spout incorporates a plastic aerator on the Sparkling/Chilled and the Ambient outlet, and a separate outlet for the boiling water. Both model ranges incorporate a vent outlet within the tap spout for the boiling water circuit. Maximum working pressure 5.0 bar (Ambient (hot and cold) circuit only). 95458xxx models - Boiling circuit has a maximum operating temperature of 100°C. All other circuits have a maximum operating temperature of 65°C. 95459xxx models - Boiling circuit has a maximum operating temperature of 100°C. The ambient circuit has a maximum operating temperature of 65°C. The chilled/sparkling circuit has a maximum operating temperature of 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied or part of this approval) and a ceramic cartridge headwork with single lever operating member controlling the flow of normal mixed water. The spout outlet incorporates a plastic aerator. Maximum working pressure: 5.0 Bar. Maximum operating temperature: 98.0°C.
Tudor range of above and under sink range of electrically heated vented water heaters (cased and insulated) incorporating an angle valve on the inlet for flow control. Maximum working pressure 3.5 bar. Maximum operating temperature 75°C.
Range of installation kits comprising of a water block, double check valve assembly (suitable for backflow protection against fluid category 3) and a pressure reducing valve (outlet pressure range 3.0 to 3.5 bar). Model 95428 incorporates a water filter. Maximum working pressure: 16 Bar Maximum operating temperature: 23°C
Page 2 of 2
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.