Valves

Section Code 2185 : Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.

Back To Directory Sections

#1907334

Range of metal seated, swing gate, non-return valves with (blue or red epoxy powder coated) ductile iron bodies and EPDM rubber coated ductile iron swing gates. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
1907334
Expiry date:
31/07/2024
Size:
DN50 - 300
Marking:
MECH logo (trademark of Jinan Meide Casting Co. Ltd.), PN, DN, date of manufacture (YYMMDD), flow arrow, UL logo and other technical information on body. Body material, PN, DN date of manufacture (YYMMDD), max. temp and pressure on data plate on flange connection.
Installation Requirements:
R001
Model:
H44X2
Manufacturer:
Jinan Meide Casting Co. Ltd.
Company Name
Jinan Meide Casting Co. Ltd.
Address
NO.1 MEIDE STREET MEIGUI TOWN PINGYIN COUNTY JINAN SHANDONG 250400
Country
China

View All Listings by this Company

Print This Approval


#1908809

Range of wafer or globe type spring loaded, resilient trim, non-return valves with cast iron bodies (blue epoxy powder coated) with stainless steel springs and guides. Maximum working pressure 16.0 bar. The maximum operating temperature is 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
1908809
Expiry date:
31/08/2024
Size:
See Model
Marking:
Weflo, production date (YYMMDD) CI, size (DN), pressure rating (PN) and flow arrow on body. Weflo, product code (fig 5106 or fig 5306 depending on model) and WRAS on data plate on body.
Installation Requirements:
R001
Model:
Globe 5106: DN50 - DN300. Wafer 5306: DN50 - DN600.
Factor:
Weflo Valve Co. Ltd.
Company Name
Weflo Valve Co. Ltd.
Address
45 Xinghe Road, Lancun Town, Jimo
Country
Qingdao,

View All Listings by this Company

Print This Approval


#1908818

Range of globe type spring loaded, resilient trim, non-return valves with cast iron bodies (blue epoxy powder coated) with stainless steel springs and guides. Maximum working pressure 16.0 bar. The maximum operating temperature is 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
1908818
Expiry date:
31/08/2024
Size:
See Model
Marking:
HATTERSLEY, PN, MAXIMUM TEMPERATURE, WRAS & FIG 160W ON DATAPLATE ON BODY DN, PN, HATTERSLEY, WRAS, FLOW ARROW, EN & PRODUCTION DATE YY/MM/DD ON BODY
Installation Requirements:
R001
Model:
FIG160W: DN50 - DN300.
Factor:
Hattersley
Company Name
Hattersley
Address
Crane House, Epsilon Terrace, West Road, Ipswich
Postcode
IP3 9FJ

View All Listings by this Company

Print This Approval


#1908819

Range of globe type spring loaded, resilient trim, non-return valves with cast iron bodies (black epoxy powder coated) with stainless steel springs and guides. Maximum working pressure 16.0 bar. The maximum operating temperature is 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
1908819
Expiry date:
31/08/2024
Size:
See Model
Marking:
CRANE, PN, WRAS, D130W & TEMPERATURE ON DATAPLATE ON BODY DN, PN, CRANE, FLOW ARROW & DATE OF MANUFACTURE YY/MM/DD ON BODY
Installation Requirements:
R001
Model:
D130W
Factor:
Crane Ltd
Company Name
Crane Ltd
Address
Crane House, Epsilon Terrace, West Road, Ipswich
Postcode
IP3 9FJ
Phone
01473 277 364
General Email
bwiggins@crane-ltd.co.uk

View All Listings by this Company

Print This Approval


#1908822

Range of wafer type spring loaded, resilient trim, non-return valves with cast iron bodies (blue epoxy powder coated) with stainless steel springs and guides. Maximum working pressure 16.0 bar. The maximum operating temperature is 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
1908822
Expiry date:
31/08/2024
Size:
See Model
Marking:
VALVES INSTRUMENTS PLUS LOGO (VIP), WRAS, TEMPERATURE, CI & 16 BAR ON DATA PLATE ON BODY. PN, DN & FLOW ARROW ON BODY
Installation Requirements:
R001
Model:
00/0168: DN50 - DN300.
Factor:
Valves Instruments Plus Ltd
Company Name
Valves Instruments Plus Ltd
Address
VIP House Chaddock Lane Astley Manchester
Postcode
M29 7JT
Country
United Kingdom
Phone
01942 885 700

View All Listings by this Company

Print This Approval


#1911320

Range of spring loaded, resilient trim, non-return valves with brass bodies and EPDM seals. Maximum working pressure ½”, ¾”, 1” at 12 bar, 1 ¼”, 1 ½”, 2” at 10 bar. Maximum operating temperature: 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
1911320
Expiry date:
30/11/2024
Size:
see model
Marking:
Conex, flow arrow, size and pressure rating on body
Installation Requirements:
R001
Model:
PN12: 145110FF0120404 – ½” BSP (F) 145110FF0120606 – ¾” BSP (F) 145110FF0120808 – 1” BSP (F) PN10: 145110FF0101010 – 1 ¼” BSP (F) 145110FF0101212 – 1 ½” BSP (F) 145110FF0101616 – 2” BSP (F)
Manufacturer:
Conex Universal Ltd
Company Name
Conex Universal Ltd
Address
Global House 95 Vantage Point The Pensnett Estate Kingswinford
Postcode
DY6 7FT
Country
United Kingdom
Phone
+44 121 5772831

View All Listings by this Company

Print This Approval


#2001011

Range of spring loaded, resilient trim, non-return valves with brass bodies and EPDM seals. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2001011
Expiry date:
31/01/2025
Size:
See model.
Marking:
DN, PN, FLOW ARROW and OV (OV for Oventrop) on body
Installation Requirements:
R001
Model:
DN 10 - 107 21 03 DN 15 - 107 21 04 DN 20 - 107 21 06 DN 25 - 107 21 08 DN 32 - 107 21 10 DN 40 - 107 21 12 DN 50 - 107 21 16
Manufacturer:
Oventrop GmbH & Co KG
Company Name
Oventrop GmbH & Co KG
Address
Paul-Oventrop-Strasse 1, 59939 Olsberg
Country
Germany

View All Listings by this Company

Print This Approval


#2006802

Range of spring loaded, resilient trim, non-return valves with cast iron bodies (blue epoxy powder coated) with stainless steel discs and an EPDM seal. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2006802
Expiry date:
30/06/2025
Size:
DN50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600
Marking:
Weflo, Size, PN, Flow arrow and date of manufacture (YY-MM-DD) on body. Weflo and Fig. 5306 on data plate on body.
Installation Requirements:
R001
Model:
5306
Manufacturer:
Weflo Valve Co. Ltd.
Company Name
Weflo Valve Co. Ltd.
Address
45 Xinghe Road, Lancun Town, Jimo
Country
Qingdao,

View All Listings by this Company

Print This Approval


#2003033

Range of spring loaded resilient trim, non-return valves with blue epoxy coated ductile iron bodies, stainless steel discs, PTFE gaskets and EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2003033
Expiry date:
31/03/2025
Size:
DN40 - DN800 flange connection
Marking:
FSK, DN, PN and other technical info on data plate. DN, PN and DI on body.
Installation Requirements:
R001
Model:
CV11
Manufacturer:
Tianjin FSK Flow Control Equipment Co., Ltd
Company Name
Tianjin FSK Flow Control Equipment Co., Ltd
Address
NO. 5 Keda 3rd Road, TEDA Technic Park, Jinnan District
Country
Tianjin ,

View All Listings by this Company

Print This Approval


#1907396

Range of metal seated, swing gate, non-return valves with (blue or red epoxy powder coated) ductile iron bodies and EPDM rubber coated ductile iron swing gates. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
1907396
Expiry date:
31/07/2024
Size:
DN50 - 300
Marking:
SHIELD ON BODY, RANGE NAME & PRODUCT INFORMATION ON DATA PLATE
Installation Requirements:
R001
Model:
SHIELD SD-CV RANGE OF SWING GATE NON-RETURN VALVES: DN50 - 300
Factor:
SHIELD FIRE SAFETY & SECURITY LTD
Company Name
SHIELD FIRE SAFETY & SECURITY LTD
Address
Unit 3, Endeavour Drive Basildon- Essex
Postcode
SS14 3WF
Country
United Kingdom
Phone
+44 (0) 1708 377731
General Email
info@shieldglobal.com

View All Listings by this Company

Print This Approval


#2004036

Range of spring loaded, resilient trim, non-return valves with, stainless steel bodies and plunger with EPDM seals. Maximum working pressure 16.0 bar. Cold Water Use Only.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2004036
Expiry date:
30/04/2025
Size:
See model
Marking:
All Models excluding 900471A: Mondeo, size, PN, material grade, flow arrow, date of manufacture (MM/YY) & Model Code on the body Model 900471A Only: Mondeo, size, PN, material grade, flow arrow & date of manufacture (MM/YYYY) on the body.
Installation Requirements:
R001
Model:
¼" BSP Female-Female (Part number 900103A), ¼" BSP Female-Female (Part number 900106A), 3/8" BSP Female-Female (Part number 900110A) 3/8" BSP Female-Female (Part number 900112A), ½" BSP Female-Female (Part number 900117A), ½" BSP Female-Female (Part number 900120A), ¾" BSP Female-Female (Part number 900010A), ¾" BSP Female-Female (Part number 900400A), 1" BSP Female-Female (Part number 900015A), 1" BSP Female-Female (Part number 900410A), 1¼” BSP Female-Female (Part number 900020A), 1¼” BSP Female-Female (Part number 900420A), 1½” BSP Female-Female (Part number 900025A), 1½” BSP Female-Female (Part number 900430A), 2" BSP Female-Female (Part number 900028A), 2" BSP Female-Female (Part number 900440A), 2½” BSP Female-Female (Part number 900056A), 2½” BSP Female-Female (Part number 900451A), 3" BSP Female-Female (Part number 900461A), 4" BSP Female-Female (Part number 900471A), 1" BSP Male-Female (Part number 900017MFA), 1¼” BSP Male-Female (Part number 900022MFA), 1½” BSP Male-Female (Part number 900027MFA), 2" BSP Male-Female (Part number 900030MFA).
Manufacturer:
Mondeo Srl.
Company Name
Mondeo Srl.
Address
Via Dot. Lombardi 19, 36075 Montecchio Maggiore, Vicenza
Country
Italy

View All Listings by this Company

Print This Approval


#2005030

Range of spring loaded, resilient trim, non-return valves with epoxy coated ductile iron bodies, stainless steel discs and EPDM seats. Maximum working pressure 16.0 bar. Maximum operating temperature 85⁰C

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2005030
Expiry date:
31/05/2025
Size:
DN50 to DN600 flanged
Marking:
VIR Valvoindustria Ing Logo, Flow Arrow, DN & PN on Body
Installation Requirements:
R001
Model:
776
Factor:
VIR Valvoindustria Ing. Rizzio S.p.A.
Company Name
VIR Valvoindustria Ing. Rizzio S.p.A.
Address
Via Circonvallazione n. 10, 13018 Valduggia (VC)
Country
Italy

View All Listings by this Company

Print This Approval


#2007329

Range of spring loaded, resilient trim, non-return valves with brass bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2007329
Expiry date:
31/07/2025
Size:
See model.
Marking:
IDC logo (E), size, flow arrow and PN on Body
Installation Requirements:
R001
Model:
1CVC004N – ½” BSP (F) 1CVC006N – ¾” BSP (F) 1CVC008N – 1” BSP (F)
Factor:
IDC Plumbing & Heating Technology (Beijing) Ltd
Company Name
IDC Plumbing & Heating Technology (Beijing) Ltd
Address
3rd Floor, Unit 2, Building 2, Section A Zhaowei Science & Technology Park No. 14, Jiuxianqiao Road Chaoyang District Beijing
Postcode
100016
Country
China

View All Listings by this Company
Manufacturer:
IDC FLUID CONTROL CO., LTD
Company Name
IDC FLUID CONTROL CO., LTD
Address
Mechanical & Electronic Industrial Area. C, Yuhuan, Taizhou
Country
Zhejiang,

View All Listings by this Company

Print This Approval


#2007057

‘GNVP’ range of non-return valves with a black plastic housing. The product incorporates two test/drainage plugs. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2007057
Expiry date:
31/07/2025
Size:
Flanged connection see model.
Marking:
Grundfos, PN, Product No., temperature, and other technical info on adhesive label on body. Flow arrow on body.
Installation Requirements:
R001
Model:
GNVP Range: 91040183: DN32. 91040184: DN40. 96155179: DN50-I Version. 98595908: DN50 w. DN32. 91040186: DN65. 91069032: DN80. 91040187: DN100.
Manufacturer:
Grundfos Pumpenfabrik GmbH
Company Name
Grundfos Pumpenfabrik GmbH
Address
Willy-Pelz-Strasse 1-5, 23812 Wahlstedt, Germany

View All Listings by this Company

Print This Approval


#1908823

Range of wafer type spring loaded, resilient trim, non-return valves with cast iron bodies (blue epoxy powder coated) with stainless steel springs and guides. Maximum working pressure 16.0 bar. The maximum operating temperature is 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
1908823
Expiry date:
31/08/2024
Size:
See Model
Marking:
IMI TA CAST ON BODY WRAS, DI, CE, DN & PN ON METAL DATA PLATE ON BODY
Installation Requirements:
R001
Model:
Wafer 43350 TA-NRV F RANGES OF NON-RETURN VALVES: DN50-600
Factor:
IMI Hydronic Engineering
Company Name
IMI Hydronic Engineering
Address
Route de Crassier 19, CH-1262 Eysins, Switzerland

View All Listings by this Company

Print This Approval


#1907404

Range of metal seated, swing gate, non-return valves with (blue or red epoxy powder coated) ductile iron bodies and EPDM rubber coated ductile iron swing gates. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
1907404
Expiry date:
31/07/2024
Size:
DN50 - 300
Marking:
RAPIDROP, PN, DN, DI, date of manufacture (YYYY) & flow arrow, on body. WRAS, RAPIDROP LOGO, Body material, PN, DN date of manufacture (YYMMDD), max. temp and pressure on data plate on flange connection.
Installation Requirements:
R001
Model:
FIG.302 SWING GATE NON-RETURN VALVES: DN50 - 300
Factor:
Rapidrop Global Limited
Company Name
Rapidrop Global Limited
Address
Rutland Business Park, Newark Road, Peterborough
Postcode
PE1 5WA
Phone
+44 (0) 1733 847 510
General Email
rapidrop@rapidrop.com

View All Listings by this Company

Print This Approval


#2105802

Range of spring loaded, resilient trim, non-return valves (blue epoxy coated cast iron body), with bronze bushing, stainlesss steel spring and disc, and EPDM seat. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2105802
Expiry date:
31/05/2026
Size:
DN50-300 flanged
Marking:
AFA and logo, size and flow arrow on body. AFA and logo, maximum temperature, maximum pressure, body and disk material and flange drilling on plate on body (AFA is a trademark of Jiwa Industries PTE Ltd.)
Installation Requirements:
R001
Model:
Fig 98 Silent Non-Return valve: AFA Brand model 98
Factor:
Jiwa Industries PTE Ltd
Company Name
Jiwa Industries PTE Ltd
Address
No. 16 Fan Yoong Road, Singapore, 629793

View All Listings by this Company
Manufacturer:
Sinpro (Dezhou) Industries Co. Ltd
Company Name
Sinpro (Dezhou) Industries Co. Ltd
Address
NO 1 INDUSTRIAL PARK ROAD NINGJIN SHANDONG
Country
China

View All Listings by this Company

Print This Approval


#2105803

Range of spring loaded, resilient trim, non-return valves (blue epoxy coated cast iron body), with bronze bushing, stainlesss steel spring and disc, and EPDM seat. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2105803
Expiry date:
31/05/2026
Size:
DN50-300 flanged
Marking:
VIP, DN & PB on body. VIP, maximum temperature, maximum pressure, body and disk material and flange drilling on plate on body
Installation Requirements:
R001
Model:
VIP FIG 00/0175 NON-RETURN VALVE: (NOT SUITABLE FOR BACKFLOW PROTECTION)
Factor:
Valves Instruments Plus Ltd
Company Name
Valves Instruments Plus Ltd
Address
VIP House Chaddock Lane Astley Manchester
Postcode
M29 7JT
Country
United Kingdom
Phone
01942 885 700

View All Listings by this Company

Print This Approval


#2104332

Wafer type spring loaded, resilient trim, non-return valve with stainless steel bodies, springs and guides, and an EPDM seat. Not suitable for backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2104332
Expiry date:
30/04/2026
Size:
DN300.
Marking:
AEICO Valve, AEICO logo, size, mould, pressure, year of manufacturer (YYYY) and other technical information on data label on body
Installation Requirements:
R001
Model:
ANRV-300-16-SS
Factor:
Al-Ghammas Factory for Advanced Electromechanical Industrial Co. (AEICO)
Company Name
Al-Ghammas Factory for Advanced Electromechanical Industrial Co. (AEICO)
Address
Qassim- 1st Industrial City
Country
Saudi Arabia
Phone
+966163220087

View All Listings by this Company

Print This Approval


#1907407

Range of metal seated, swing gate, non-return valves with (blue or red epoxy powder coated) ductile iron bodies and EPDM rubber coated ductile iron swing gates. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
1907407
Expiry date:
31/07/2024
Size:
DN50 - 300
Marking:
PN, DN, date of manufacture (YYYY), flow arrow, and other technical information on body. VIKING, Body material, PN, DN date of manufacture (YYMMDD), max. temp and pressure on data plate on flange connection.
Installation Requirements:
R001
Model:
SCF SWING GATE NON-RETURN VALVES: DN50 - 300
Factor:
Viking SA
Company Name
Viking SA
Address
Zone Industrielle Haneboesch, Differdange, Luxembourg
Country
L-4562
Phone
+352-5837371 (Luxembourg)/+44-1427-871000 (UK Office)
General Email
vikinguk@vikingcorp.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 3

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.