Combination Tap Assemblies

Section Code 0445 : Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#2303065

Range of single hole single outlet fixed combination tap assemblies, (chrome plated brass), incorporating a quarter turn ceramic disc headwork with a single lever operating member and non-rising spindle headwork with a variety of operating members (See models) controlling the flow to the additional swivel spout. The product incorporates a handheld pre-rinse spray with a self-closing trigger, either on a flexible hose within an overhead spring or as a fixed length flexible hose on a swivel arm (see model). The inlets incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the swivel spouts incorporates plastic aerators. Maximum working pressure 8.6 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2303065
Expiry date:
31/03/2028
Size:
½” BSP (M).
Marking:
Top line on body. ENCORE (brand of CHG Europe B.V.) on trigger mechanism.
Installation Requirements:
R001 R006
Model:
Flexible hose within an overhead spring: TW 20-116111-S3, TW 20-117111-S3, TW 20-116111-S3-DA1, TW 20-116111-S3-DA2, TW 20-116111-S3-DA3, TW 20-116111-S3-DA4, TW 20-117111-S3-DA1, TW 20-117111-S3-DA2, TW 20-117111-S3-DA3, TW 20-117111-S3-DA4. Fixed length flexible hose on a swivel arm: TW 20-510411-S3, TW 20-511411-S3, TW 20-510411-S3-DA1, TW 20-510411-S3-DA2, TW 20-510411-S3-DA3, TW 20-510411-S3-DA4, TW 20-511411-S3-DA1, TW 20-511411-S3-DA2, TW 20-511411-S3-DA3, TW 20-511411-S3-DA4. The final number = type of operating member. 1 = Single lever, 2 = Cross top, 3 = Triangle handle, 4 = Designer lever.
Factor:
CHG Europe B.V.
Company Name
CHG Europe B.V.
Postcode
THE NETHERLANDS

View All Listings by this Company

Print This Approval


#2303057

Range of deck mounted, single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating either quarter turn ceramic disc or quarter turn compression washer headworks with various operating members (see model). The inlets of the quarter turn ceramic disc headworks incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product incorporates a handheld pre-rinse spray with a self-closing trigger, either on a flexible hose within an overhead spring or as a fixed length flexible hose on a swivel arm (see model). Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn compression washer headwork with various operating members (see model). The product is supplied with metal backnuts. Maximum working pressure 6.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2303057
Expiry date:
31/03/2028
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
ENCORE (brand of CHG Europe B.V.) on body and hand spray.
Installation Requirements:
R001 R006 R009 R010
Model:
KW 51 X1 X2 X3 X4 X5 X6 S3 (D A X7) K = Encore series. W = WRAS series. 51 = Single hole deck mount double pantry. X1 = 1 - Spring pre-rinse. 5 - Swivel arm pre-rinse - 12” arm length. X2 (Main body headwork) = 0 - Compression. 1 - Ceramic. X3 (Swivel arm support/Spring type) = 0 - W/O Swivel arm P/R support. 1 - W/ Swivel arm P/R support. 6 - Spring chrome plated. 7 - Spring stainless steel. X4 (riser) = 1 - 18” riser (only on spring type pre-rinse). 4 - 32” riser (only on swivel type pre-rinse). X5 (wall bracket) = 1 - Yes X6 (Main body operating member) = 1 - Standard lever. 2 - Cross. 3 - Triangle handle. 4 - Designer handle. 5 - 4” Wrist blade. 6 - 6” Wrist blade. S3 - Standard spray valve Optional: D - Add on faucet W/ 12” spout A - 0.5 GPM PCA Spray vandal resistant X7 (Add-on spout operating member) = 1 - Standard lever. 2 - Cross. 3 - Triangle handle. 4 - Designer handle.
Factor:
CHG Europe B.V.
Company Name
CHG Europe B.V.
Postcode
THE NETHERLANDS

View All Listings by this Company

Print This Approval


#2303058

Range of deck mounted, single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc or a quarter turn compression washer headwork with various operating members (see model). The inlet of the quarter turn ceramic disc headwork incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product incorporates a handheld pre-rinse spray with a self-closing trigger, either on a flexible hose within an overhead spring or as a fixed length flexible hose on a swivel arm (see model). Models are available with an additional swivel spout outlet, which incorporates a plastic aerator (see model). The swivel spouts have their own flow control in addition to the main headwork, this is also a quarter turn compression washer headwork with various operating members (see model). The product is supplied with metal backnuts. Maximum working pressure 6.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2303058
Expiry date:
31/03/2028
Size:
½” BSP (M).
Marking:
ENCORE (brand of CHG Europe B.V.) on body and hand spray.
Installation Requirements:
R001 R006
Model:
KW 63 X1 X2 X3 X4 X5 X6 S3 (D A X7) K = Encore series. W = WRAS series. 63 = Single hole deck mount single pantry. X1 = 1 - Spring pre-rinse. 5 - Swivel arm pre-rinse - 12” arm length. X2 (Main body headwork) = 0 - Compression. 1 - Ceramic. X3 (Swivel arm support/Spring type) = 0 - W/O Swivel arm P/R support. 1 - W/ Swivel arm P/R support. 6 - Spring chrome plated. 7 - Spring stainless steel. X4 (riser) = 1 - 18” riser (only on spring type pre-rinse). 4 - 32” riser (only on swivel type pre-rinse). X5 (wall bracket) = 1 - Yes X6 (Main body operating member) = 1 - Standard lever. 2 - Cross. 3 - Triangle handle. 4 - Designer handle. 5 - 4” Wrist blade. 6 - 6” Wrist blade. S3 - Standard spray valve Optional: D - Add on faucet W/ 12” spout A - 0.5 GPM PCA Spray vandal resistant X7 (Add-on spout operating member) = 1 - Standard lever. 2 - Cross. 3 - Triangle handle. 4 - Designer handle.
Factor:
CHG Europe B.V.
Company Name
CHG Europe B.V.
Postcode
THE NETHERLANDS

View All Listings by this Company

Print This Approval


#2212099

Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating ceramic cartridge headworks with single lever operating member. The outlet is a pull-out spray type and incorporates a plastic aerator. The inlet hoses incorporate stainless steel strainers. Models 5059340452869 have a maximum working pressure of 10.0 bar. All other models have a maximum working pressure of 5.0 bar.

Non-metallic materials and components comply with BS6920 at 60°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2212099
Expiry date:
31/12/2027
Size:
Stainless steel braided PEX lined flexible hose assemblies. Models 5059340504469: 3/8” captive nut. All other models: ½” captive nut.
Marking:
Kingfisher Good Home Logo & Date of Manufacture MM/YYYY on body
Installation Requirements:
R001 R009 R090
Model:
5059340504469, 5059340504421, 5059340452869, 5059340452876, 5059340452883, 5059340452890, 5059340452791 & 5059340452807
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval


#2301345

Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chrome plated) and pull-out spray. The products incorporate a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2301345
Expiry date:
31/01/2028
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ½” BSP captive nut end connections.
Marking:
Gessi on operating member
Installation Requirements:
R001 R009 R010 R090
Model:
60433, 60435, 60485 & 60465
Manufacturer:
Gessi S.p.A.
Company Name
Gessi S.p.A.
Address
Parco Gessi - Fraz. Vintebbio 13037 Serravalle Sesia
Country
Italy
Phone
+39 0163 454111

View All Listings by this Company

Print This Approval


#2309333

Single hole, single outlet, (swivel) combination tap assembly, incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a pull-down hose and a plastic aerator. The inlet hoses incorporate approved check valve cartridges, however, the complete assembly has not been fully tested to it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2309333
Expiry date:
30/09/2028
Size:
Stainless steel braided EPDM lined, flexible hose with ½” BSP (M) connection.
Marking:
SMR on underside of handle
Installation Requirements:
R001 R006 R010
Model:
GENIO
Factor:
Norcros Group (Holdings) Limited T/A Abode
Company Name
Norcros Group (Holdings) Limited T/A Abode
Address
Unit L Zenith Park Whailey Road
Postcode
S75 1HT
Country
Barnsley
Phone
01226 283434
General Email
pillingworth@abodedesigns.co.uk

View All Listings by this Company
Manufacturer:
SAN MARCO RUBINETTERIA S.r.l.
Company Name
SAN MARCO RUBINETTERIA S.r.l.
Address
Via Carducci 10 13867 Pray (BI)
Country
Italy
General Email

View All Listings by this Company

Print This Approval


#2311343

Single hole, single outlet (swivel) combination tap assembly (chromium plated brass bodies), incorporating a ceramic cartridge headwork with a single lever operating member. The outlet is a pull down spray type and incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2311343
Expiry date:
30/11/2028
Size:
Stainless steel braided EPDM lined flexible hose assemblies incorporating 15mm compression connections.
Marking:
PPI on Body
Installation Requirements:
R001 R090
Model:
177014
Manufacturer:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval


#2311344

Range of single hole, single outlet, (swivel), combination tap assemblies (chromium plated brass bodies), incorporating quarter turn ceramic disc headworks and single lever operating members. The outlet is a pull down spray type and incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2311344
Expiry date:
30/11/2028
Size:
Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections. 15mm compression – (137040 models only)
Marking:
PPI on Body
Installation Requirements:
R001 R006 R010
Model:
177041 137040 137040 BN
Manufacturer:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval


#2309331

Single-hole, single outlet, (swivel), combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The outlet is a pull-out spray type that incorporates a plastic aerator. The inlet of the cold supply hose and the pull-out spray handset both incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2309331
Expiry date:
30/09/2028
Size:
Cold inlet: Stainless-steel braided EPDM lined flexible hose assemblies incorporating ½” BSP (M) end connection. Hot inlet: Stainless-steel braided EPDM lined flexible hose assemblies incorporating ½” BSP captive nut end connection.
Marking:
SMR on body.
Installation Requirements:
R001 R090
Model:
Log L Pull Out
Factor:
SAN MARCO RUBINETTERIA S.r.l.
Company Name
SAN MARCO RUBINETTERIA S.r.l.
Address
Via Carducci 10 13867 Pray (BI)
Country
Italy

View All Listings by this Company
Manufacturer:
SAN MARCO RUBINETTERIA S.r.l.
Company Name
SAN MARCO RUBINETTERIA S.r.l.
Address
Via Carducci 10 13867 Pray (BI)
Country
Italy

View All Listings by this Company

Print This Approval


#2311367

Range of single hole, single outlet, (swivel), combination tap assemblies (chromium plated brass bodies), incorporating quarter turn ceramic disc headworks and single lever operating members. The outlet is a pull down spray type and incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2311367
Expiry date:
30/11/2028
Size:
Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections.
Marking:
TP on Body
Installation Requirements:
R001 R006 R010
Model:
352757 Loose Coil Tap Brushed
Factor:
Travis Perkins Plc
Company Name
Travis Perkins Plc
Address
Divisional Office Lakeside House Bedford
Postcode
NN4 7HD
Country
Northhampton
Phone
+44 (0) 1604 503457

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 9 of 10

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.