Directory Search Results

Print List

#2212024

Range of deck mounted taps for cold or premixed water (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The inlet hoses have stainless steel strainers and incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
2212024
Size:
Stainless steel braided PEX lined flexible hose assemblies with 3/8” BSP captive nut end connections.
Marking:
STERN on body.
Installation Requirements:
R001 R006 R009
Expiry date:
31/12/2027
Model:
239050 – Trendy Plus B, 239160 – Trendy Plus LE, 239051 – Trendy Plus B AB1953, 239161 – Trendy Plus LE AB1953.
Product Images

Approval Holder:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd. Yavne
Postcode
8122217
Country
Israel
Phone
+972 8 9326007
General Email
leah@sternfaucets.com

View All Listings by this Company

Print This Approval


#2212034

Range of wall mounted tap assemblies for cold or premixed water with chromium plated brass bodies. Flow is controlled by a solenoid valve activated via an infra-red sensor and the spout outlets have plastic aerators. Supplied with stainless steel braided PEX lined connection hoses. Maximum working pressure 8.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
2212034
Size:
10mm spigot.
Marking:
Stern logo on sensor plate.
Installation Requirements:
R001 R007 R040
Expiry date:
31/12/2027
Model:
340300 – Extreme WMB, 340200 – Extreme WME, 340400 – Extreme WM LB, 340500 – Extreme WM LE.
Product Images

Approval Holder:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd. Yavne
Postcode
8122217
Country
Israel
Phone
+972 8 9326007
General Email
leah@sternfaucets.com

View All Listings by this Company

Print This Approval


#2212038

Range of single hole, single outlet, electronically controlled tap assemblies (chrome plated brass body). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Supplied with a stainless steel braided PEX lined flexible connection hose and a manual lever for controlling the temperature. Maximum working pressure 8.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
2212038
Size:
½” BSP male
Marking:
Stern on top of body.
Installation Requirements:
R001 R006 R009 R010
Expiry date:
31/12/2027
Model:
239200 - Trendy 1000B, 239300 - Trendy 1000E, 239600 - Trendy 1000LB, 239700 - Trendy 1000LE, 239201 - Trendy 1000B AB1953, 239301 - Trendy 1000E AB1953, 239601 - Trendy 1000LB AB1953, 239701 - Trendy 1000LE AB1953.
Product Images

Approval Holder:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd. Yavne
Postcode
8122217
Country
Israel
Phone
+972 8 9326007
General Email
leah@sternfaucets.com

View All Listings by this Company

Print This Approval


#2112367

Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2112367
Size:
½” BSP (M)
Marking:
Tissino on flush plate, Tissino on label inside cistern and 6l water line.
Installation Requirements:
R001 R556 R571
Expiry date:
31/12/2026
Model:
TRC-101 ROCCO 2 & TRC-107 ROCCO 2

Approval Holder:
Tissino Ltd.
Company Name
Tissino Ltd.
Address
Unit 2 A Lyncastle Road Appleton Thorn Warrington
Postcode
WA4 4SN
Country
Cheshire

View All Listings by this Company

Print This Approval


#2112368

Range of concealed WC flushing cisterns incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2112368
Size:
½” BSP (M)
Marking:
Tissino on flush plate, Tissino on label inside cistern and 6l water line.
Installation Requirements:
R001 R556
Expiry date:
31/12/2026
Model:
TRC-104 ROCCO 2 SLIMLINE & TRC-106 ROCCO 2

Approval Holder:
Tissino Ltd.
Company Name
Tissino Ltd.
Address
Unit 2 A Lyncastle Road Appleton Thorn Warrington
Postcode
WA4 4SN
Country
Cheshire

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 997 of 2264

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.