#2107036

Range of wall mounted compact shower panels with push button timed flow control. The inlet incorporates a plastic flow regulator and a stainless-steel strainer. Maximum working pressure 4.0 Bar Maximum operating temperature 60°C

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
2107036
Size:
½” BSP (M)
Marking:
INTA on operating member
Installation Requirements:
R001 R040
Expiry date:
31/07/2026
Model:
SP9206CP & SP9207CP.
Product Images

Approval Holder:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company
Manufacturer:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company

Print This Approval


#2107045

Concealed installation set for use with wall mounted overhead shower outlets (brass body – various finishes). The inlet to the shower outlet incorporates a stainless-steel strainer, a plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
2107045
Note:
Open outlet use only. The 28 486 180 concealed installation set is not approved in its own right.
Size:
Concealed installation set: ½” BSP (F). Shower outlets: ½” BSP (M).
Marking:
AXOR on body.
Installation Requirements:
R001 R040
Expiry date:
31/07/2026
Model:
Concealed installation set: 28 486 180 AXOR ShowerSolutions Basic set. Shower outlets: 28 491 xxx AXOR ShowerSolutions, 36 822 xxx AXOR Citterio E. Where xxx denotes the surface finish (which is a non-water contact part). It will always be 3 digits, which can be any combination of numbers and/or letters, as examples: 000 = chrome optic finish, 800 = PVD stainless steel optic finish.
Product Images

Approval Holder:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company
Manufacturer:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company

Print This Approval


#2106322

Range of Y pattern strainers incorporating blue epoxy coated ductile iron bodies and stainless steel mesh filter. With PN16 flanges to BS EN 1092-2. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1715 Strainers
Size:
See model
Marking:
Herz logo, DN size, PN16, CE & flow arow on body Herz & part no (first 5 digits) on data label on body.
Installation Requirements:
R001
Expiry date:
30/06/2026
Model:
4 4111 71 – DN65 4 4111 72 – DN80 4 4111 73 – DN100 4 4111 74 – DN125 4 4111 75 – DN150 4 4111 76 – DN200
Product Images

Approval Holder:
Herz Armaturen GmbH
Company Name
Herz Armaturen GmbH
Address
Richard - Strauss Strasse 22, A-1230, Vienna
Country
Austria

View All Listings by this Company
Manufacturer:
Herz Armaturen GmbH
Company Name
Herz Armaturen GmbH
Address
Richard - Strauss Strasse 22, A-1230, Vienna
Country
Austria

View All Listings by this Company

Print This Approval


#2106333

Range of Y pattern strainers with a bronze body and stainless steel mesh. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.

Section:
1715 Strainers
Size:
Please refer to model.
Marking:
Crane, PN, size, flow arrow on body. Crane, WRAS, temp, model, pressure and other technical information on data plate on body.
Installation Requirements:
R001
Expiry date:
30/06/2026
Model:
D295: ½” - 2” BSP (F). D295 AT: ½” - 2” NPT (F).
Product Images

Approval Holder:
Crane Ltd
Company Name
Crane Ltd
Address
Crane House, Epsilon Terrace, West Road, Ipswich
Postcode
IP3 9FJ
Country
United Kingdom
Phone
01473 277 364
General Email
tturner@cranebsu.com

View All Listings by this Company

Print This Approval


#2012087

Range of flow switches with brass bodies incorporating EPDM ‘O’-rings, acting as a leak detection system that actuates an integral spherical valve to shut off the water supply. The inlet incorporates a stainless steel strainer. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 30°C.

Section:
1719 Flow Activated Switches
WRAS Approval Number:
2012087
Note:
Cannot be used as the main stop valve into a premises. The fitting listed on this approval has been judged only against the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. The decision of the Scheme to list them is not to be taken as any guide as to their effectiveness to do the job for which they have been designed.
Size:
¾”, 1” & 1¼” BSP (M) inlet/outlet.
Marking:
RELIANCE VALVES ON PLASTIC COVER
Installation Requirements:
R001
Expiry date:
31/12/2025
Model:
LEKP100001 - ¾, LEKP100002 1” & LEKP100003 1¼ FLOW ACTIVATED SWITCHES
Product Images

Manufacturer:
Reliance Worldwide Corporation
Company Name
Reliance Worldwide Corporation
Address
Horton Road, West Drayton
Postcode
UB7 8JL
Country
United Kingdom
Phone
+44 7730 052060

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 98 of 827

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.