Directory Search Results

Print List

#2104086

Dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2104086
Size:
2” BSP (M)
Marking:
Flume, B4910GA on base
Installation Requirements:
R001 R571
Expiry date:
30/04/2026
Model:
AB771
Product Images

Approval Holder:
Toolstation Ltd.
Company Name
Toolstation Ltd.
Address
Travis Perkins PLC Ryehill House Rye Hill Close Lodge Farm Industrial Estate Northampton
Country
United Kingdom
Phone
07392109053
General Email
benjamin.cockerill@travisperkins.co.uk

View All Listings by this Company

Print This Approval


#251104003

Stainless steel plate heat exchangers with copper brazing.

Section:
1350 Heat Exchangers
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
0.75 to 2”.
Marking:
UK Exchangers and product info on label.
Installation Requirements:
R001
Expiry date:
30/11/2030
Model:
UKE-BR030 UKE-BR040 UKE-BR060H UKE-BR050 UKE-BR050R UKE-BR095H BR200L UKE-BR200M UKE-BR205 UKE-BRX12B

Approval Holder:
UK Exchangers Ltd
Company Name
UK Exchangers Ltd
Address
Unit 55 Stilebrook Road Olney
Postcode
MK46 5EA
Country
United Kingdom
General Email
alex@ukeltd.com

View All Listings by this Company

Print This Approval


#250904711

Range of floor-standing gas combination boilers, supplied with isolation valves, expansion vessel and a pressure relief valve set at 3.0 bar. Maximum working pressure: Primary circuit 2.5 bar, secondary 10 bar. Maximum operating temperature: Primary 82°C / secondary circuit 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
250904711
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
22mm compression.
Marking:
Worcester on front cover. Worcester and product info on label inside cover.
Installation Requirements:
R001 R140 R360
Expiry date:
30/09/2030
Model:
7-731-600-297 Greenstar 8000F 35kW Combi NG, 7-731-600-298 Greenstar 8000F 35kW Combi LPG, 7-731-600-299 Greenstar 8000F 50kW Combi NG, 7-731-600-300 Greenstar 8000F 50kW Combi LPG.
Product Images

Approval Holder:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Danesmoor Works Pilsley Clay Cross Chesterfield Derbyshire
Postcode
S45 9BY

View All Listings by this Company

Print This Approval


#250902003

Range of in-line water meters incorporating bronze copper alloy bodies and EPDM O rings. Maximum working pressure 10.0 Bar Maximum operating temperature 30.0°C

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See models
Marking:
EMS, Model and other technical data on water meter dial
Installation Requirements:
R001
Expiry date:
30/09/2030
Model:
TH15 – DN 15 CNPA 49 Male Pipe Thread (25.8mm) TH20 – DN 20 CNPA 49 Male Pipe Thread (33mm) TH25 – DN 25 CNPA 49 Male Pipe Thread (39mm)
Product Images

Approval Holder:
Energy Management System Co. Ltd.
Company Name
Energy Management System Co. Ltd.
Address
No8, Dali 3rd Rd., Shanhua District, Southern Taiwan Science Park (STSP) Tainan City, Taiwan
Phone
+886-6-5050207

View All Listings by this Company
Manufacturer:
Energy Management System Co. Ltd.
Company Name
Energy Management System Co. Ltd.
Address
No8, Dali 3rd Rd., Shanhua District, Southern Taiwan Science Park (STSP) Tainan City, Taiwan
Phone
+886-6-5050207

View All Listings by this Company

Print This Approval


#251002020

Range of ultrasonic dry type water meters with brass bodies. Maximum working pressure 16.0 Bar. Maximum operating temperature 50.0°C.

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See Models
Marking:
BAYLAN, model number and other technical information on meter face. Flow arrow on body
Installation Requirements:
R001
Expiry date:
31/10/2030
Model:
ST-15. DN15 - thread size ¾” BSP (M). Lengths - 110mm, 115mm, 130mm, 145mm, 165mm, 170mm, 190mm. ST-20. DN20 - thread size 1” BSP (M). Lengths - 110mm, 115mm, 130mm, 135mm, 165mm, 175mm, 190mm, 200mm, 220mm. ST-25. DN25 - thread size 1 ¼” BSP (M). Lengths - 175mm, 199mm, 200mm, 210mm, 225mm. ST-32. DN32 - thread size 1 ½” BSP (M). Lengths - 110mm, 150mm, 175mm, 199mm, 200mm ST-40. DN40 - thread size 2” BSP (M). Lengths - 200mm, 220mm.

Approval Holder:
BAYLAN OLCU ALETLERI SAN. TICARET
Company Name
BAYLAN OLCU ALETLERI SAN. TICARET
Address
ANONIM SIRKETI AOSB 10032 SOKAK NO 16 CIGLI IZMIR TURKEY

View All Listings by this Company
Manufacturer:
BAYLAN OLCU ALETLERI SAN. TICARET
Company Name
BAYLAN OLCU ALETLERI SAN. TICARET
Address
ANONIM SIRKETI AOSB 10032 SOKAK NO 16 CIGLI IZMIR TURKEY

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 819 of 846

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.