Directory Search Results

Print List

#2110326

Range of indirect and direct unvented storage cylinders consisting of either no coil (GLE) or a factory fitted single (GLC) or twin coil (GLT). The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@85˚C for 1.0-6.0 bar products and 10.5 bar@95°C for 6.0-10.0 bar products. The products are supplied with an inlet control group (safety kit) consisting of a pressure reducing valve, an expansion relief valve 6.0 bar (1.0-6.0 bar products) or 10.5 bar (6.0-10.0 bar products) and an approved check valve, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is also supplied with an expansion vessel. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
Size:
1 ½” BSP (M) secondary (inlet kit) 1 ½” BSF (F) secondary cylinder 1” BSP( F) primary coils
Marking:
Adveco badge on casing Serial No, Adveco, address, model no. capacity, & other tech info on adhesive label on body G3 warning label, maintenance label, service label, energy label on casing
Installation Requirements:
R001 R040
Expiry date:
31/10/2026
Model:
Adveco GLE Range GLE 200, GLE 300, GLE 500, GLE 750, GLE1000 Adveco GLC Range GLC 200, GLC 300, GLC 500, GLC 750, GLC 1000. Adveco GLT Range GLT 200, GLT 300, GLT 500, GLT 750, GLT1000
Product Images

Approval Holder:
Adveco Ltd
Company Name
Adveco Ltd
Address
Unit 7 & 8 Armstrong Mall Southwood Business Park Farnborough Hants
Postcode
GU14 0NR
Country
United Kingdom
Phone
01252 551 540
General Email
enquiries@adveco.co

View All Listings by this Company

Print This Approval


#2201019

Range of “MEGAAIR” bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added January 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
1890 Unvented Heating Apparatus
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression. Return circuit: 22mm compression.
Marking:
“Whitewolf” and “Megaair” Logo on front of cylinder. Product data label consisting of capacity, pressures and other technical information on front of body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/01/2027
Model:
WHITEWOLF MEGAAIR DIRECT UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 120 to 300 L): WWMxxxD WHITEWOLF MEGAAIR 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 120 to 300 L): WWMxxxI WHITEWOLF MEGAAIR 90 DIRECT SLIM UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 90 to 200 L): WWMSxxxD WHITEWOLF MEGAAIR 90 INDIRECT SLIM UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 90 to 200 L): WWMSxxxI Where xxx denotes the capacity in L and can be replaced by any of the following: 90, 120, 150, 170, 200, 250 or 300
Product Images

Approval Holder:
Whitewolf Cylinders Ltd
Company Name
Whitewolf Cylinders Ltd
Address
Unit 2, 30 Junction Business Park 119/121 Ouzlewell Green Lofthouse, West Yorkshire
Postcode
WF3 3QW
Country
United Kingdom
Phone
01132 822710
General Email
mail@whitewolfcylinders.com

View All Listings by this Company

Print This Approval


#2107053

Range of air release valves with blue epoxy coated ductile iron bodies and EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.

Section:
1980 Valves
Section Subtitle:
Air venting. Fittings in this section are suitable for above ground installations only.
WRAS Approval Number:
2107053
Size:
DN50 to DN200 flanged
Marking:
R&D Multiples, pressure rating (PN), serial no. and model on data plate on body. R&D, size, pressure rating (PN) on body.
Installation Requirements:
R001
Expiry date:
31/07/2026
Model:
Bi-Stream ARV 50mm. Bi-Stream ARV 80mm. Bi-Stream ARV 100mm. Bi-Stream ARV 150mm. Bi-Stream ARV 200mm.
Product Images

Approval Holder:
R&D Multiples (Metal Cast) Pvt Ltd
Company Name
R&D Multiples (Metal Cast) Pvt Ltd
Address
Survey No 304 Village Balda Pardi 396 125 District India

View All Listings by this Company
Manufacturer:
R&D Multiples (Metal Cast) Pvt Ltd
Company Name
R&D Multiples (Metal Cast) Pvt Ltd
Address
Survey No 304 Village Balda Pardi 396 125 District India

View All Listings by this Company

Print This Approval


#2201068

A range of wall mounted self-closing shower valves (chromium plated brass), incorporating a spring loaded headwork with a dome type operating member. Model TF222CP250 is supplied with metal back nut. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.

Section:
2000 Shower Valves
Section Subtitle:
Shower valve(s) with manual temperature control.
WRAS Approval Number:
2201068
Size:
15mm compression inlet and outlet:
Marking:
INTA on operating member
Installation Requirements:
R001 R040
Expiry date:
31/01/2027
Model:
TF992 CP TF99230 CP TF99730 CP TF997 CP TF222 CP 150 TF222 CP 200 TF222 CP 250
Product Images

Approval Holder:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company
Manufacturer:
Idral S.p.A.
Company Name
Idral S.p.A.
Address
Via Isei, 8/10 - I-28010 Gargallo (NO)
Country
Italy
Phone
+39 0322 912017
General Email

View All Listings by this Company

Print This Approval


#2105053

Range of wall mounted, thermostatic, shower mixers incorporating brass bodies (various finishes) 2-way ceramic disc diverter headwork to control the flow between two shower outlets with various operating members (see model). The A47203VUK model uses two ‘detent’ (push to on push to off) headworks to control the flow to each outlet. Temperature is controlled independently via a thermostatic cartridge using various operating members (see model) that also incorporates a manual override button. The inlets incorporate a combined EPDM washer and stainless-steel strainer or stainless steel strainer (A47203VUK model) and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower incorporates a combined EPDM washer and stainless-steel strainer. The products are supplied with a shower head, shower hose and handset. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.

Section:
2010 Shower Valves
Section Subtitle:
Shower valve(s) with thermostatic temperature control
WRAS Approval Number:
2105053
Size:
See model.
Marking:
Vitra on shower head, shower handset and body
Installation Requirements:
R001 R010 R040
Expiry date:
31/05/2026
Model:
15mm compression fitting: A47200VUK 2 way with shower column ½” x ¾” offset union: A47201VUK 2 way with shower column, A47202VUK 2 way with shower column, A47205VUK 2 way with shower column, A4720536VUK 2 way with shower column, A4720534VUK 2 way with shower column, A4720526VUK 2 way with shower column, ½” x 20mm spigot offset union: A47203VUK 2 way with shower column, Model added December 2022: 15mm compression fitting A4720523VUK 2 way with shower column
Product Images

Approval Holder:
Eczacibasi Building Materials Vitra Faucet Division
Company Name
Eczacibasi Building Materials Vitra Faucet Division
Address
4 Eylul Mah. I.Inonu Cad. Duzdag Yolu1 No: 4 11300 Bozuyuk - Bilecik
Country
Turkey
Phone
+90 228 314 07 90

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 73 of 224

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.