Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240502715
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DHW: 15mm compression. CH: 22mm compression
Marking:
Range name on front cover, Model, Max pressure, Max temperature and product information on data plate on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2029
Model:
Models without a filing loop supplied: 0010016113 - Glow-worm ESSENTIAL 24c -A (H-GB) 0010016115 - Glow-worm ESSENTIAL 28c -A (H-GB) 0010016127 - Heatline CAPRIZ 2 24c -A (H-GB) 0010016128 - Heatline MONZA 2 24c -A (H-GB) 0010016129 - Heatline CAPRIZ 2 28c -A (H-GB) 0010016130 - Heatline MONZA 2 28c -A (H-GB) 0010021401 - Glow-worm EASICOM 3 24c -A (H-GB) 0010021402 - Glow-worm EASICOM 3 28c -A (H-GB) 0010020392 - Vaillant VUW 256/6-3 (H-GB) ecoFIT sustain 825 0010020393 - Vaillant VUW 306/6-3 (H-GB) ecoFIT sustain 830 0010020394 - Vaillant VUW 356/6-3 (H-GB) ecoFITsustain 835 Models with a filling loop supplied: 0010020389 - Vaillant VUW 256/6-3 (H-GB) ecoFIT pure 825 0010020390 - Vaillant VUW 306/6-3 (H-GB) ecoFIT pure 830 0010020391 - Vaillant VUW 356/6-3 (H-GB) ecoFIT pure 835 0010019813 - Vaillant VUW 306/6-3 (P-GB) ecoFIT pure 830 P 0010021204 - Glow-worm BETACOM 4 24c -A (H-GB) 0010021205 - Glow-worm BETACOM 4 30c -A (H-GB) 0010021404 - Glow-worm ULTIMATE 3 30c -A (H-GB) 0010021405 - Glow-worm ULTIMATE 3 35c -A (H-GB) 0010027591 - Glow-worm ENERGY 2 30c -A (P-GB) 0010035896 - Glow-worm ENERGY 7 25c (H-GB) 0010035897 - Glow-worm ENERGY 7 30c (H-GB) 0010035898 - Glow-worm ENERGY 7 35c (H-GB)

Approval Holder:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company

Print This Approval


#240502720

Range of wall mounted combination boilers providing domestic hot water (DHW) via a plate heat exchanger and pressurised central heating (CH) system. Incorporating a pressure relief valve set at 3.0 bar and expansion vessel. Supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressure Primary circuit (CH) 2.5Bar, Secondary circuit (DHW) 10.0 Bar Maximum operating temperature 90.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240502720
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Primary circuit (CH) ¾” BSP (M), Secondary circuit (DHW) ½” BSP (M).
Marking:
NAVIEN on front of boiler. NAVIEN, Model Number, Max Pressure and other technical info on adhesive label on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2029
Model:
NCB300-28K NCB300-37K NCB300-41K Model added July 2024 NCB300-30K

Approval Holder:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company
Manufacturer:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company

Print This Approval


#240507702

Range of integrated water circuits incorporating a plate heat exchanger. The units incorporate a flow sensor, pressure relief valve set at 3.0 bar, and a primary circuit circulation pump. Maximum working pressure secondary circuit 10.0 bar. Maximum working pressure primary circuit 2.5 bar. Maximum operating temperature 70°C. Cold supply only.

Section:
1478 Heater
Section Subtitle:
Combination boilers - accessories and components.
WRAS Approval Number:
240507702
Size:
IWC Std.: Secondary circuit: ½” BSP (M) inlet x ½” BSP (M) outlet. Primary circuit: ¾” BSP (M) inlet x ¾” BSP (M) outlet. IWC Fgr.: Secondary circuit: F4 connection inlet x ½” BSP (M) outlet. Primary circuit: F4 connection inlet x ¾” BSP (M) outlet. IWC Rgr.: Secondary circuit: ½” BSP (M) inlet x F4 connection outlet. Primary circuit: ¾” BSP (M) inlet x ¾” BSP (M) outlet.
Marking:
Flow groups (IWC Fgr.): Grundfos part code, date of manufacture (DD/MM/YY hh:mm:ss), GRUNDFOS and QR code on adhesive label on body. Return groups (IWC Rgr.): Grundfos name and logo on pump. IWC Std.: Complete products will include the markings of the flow and return groups.
Installation Requirements:
R001 R008
Expiry date:
31/05/2029
Model:
IWC Std. UPM3/UPM4/UPS-xx CHB -xx pl xxx-xxxxxxxx The IWC Std. comprises of the following Flow and Return groups (available separately). IWC Fgr xxx-xxxxxxxx. IWC Rgr UPM3/UPM4-xx CHB xxx-xxxxxxxx. Where (as applicable): -xx = Pump max head. -xx pl = Plate heat exchanger number of plates (10-32). xxx-xxxxxxxx = Replaced by letters and/or numbers and do not have any bearing on water contact parts.

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#240402068

Range of in-line ultrasonic water meters with blue epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DN50-200 flanged.
Marking:
Baylan on dial cover. Baylan, flow arrow and size on body.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
UW-6: DN50 (port length 200mm), UW-0: DN65 (port length 200mm), UW-1: DN80 (port length 225mm), UW-2: DN100 (port length 250mm), UW-3: DN125 (port length 250mm), UW-4: DN150 (port length 300mm), UW-5: DN200 (port length 350mm).

Approval Holder:
BAYLAN OLCU ALETLERI SAN. TICARET
Company Name
BAYLAN OLCU ALETLERI SAN. TICARET
Address
ANONIM SIRKETI AOSB 10032 SOKAK NO 16 CIGLI IZMIR TURKEY

View All Listings by this Company
Manufacturer:
BAYLAN OLCU ALETLERI SAN. TICARET
Company Name
BAYLAN OLCU ALETLERI SAN. TICARET
Address
ANONIM SIRKETI AOSB 10032 SOKAK NO 16 CIGLI IZMIR TURKEY

View All Listings by this Company

Print This Approval


#240504702

‘Monsoon Standard’ range of single and twin ended shower booster pumps with brass bodies, brass impellers, EPDM seals and NBR ‘O’-rings. The inlet(s) of the pump body incorporate(s) a plastic strainer. Models with push fit connections include an integral isolation valve. Pushfit connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240504702
Note:
R007 & R009 applies to the 21mm & 22mm pushfit inlet/outlet hoses.
Size:
44428 - Monsoon S1.5 bar Twin EXIP model: ¾” BSP (M) (inlet/outlet). ROI suffix models: Stainless steel braided EPDM lined flexible hose assemblies incorporating 21mm push-fit end connections (inlet/outlet). EXP suffix models: Stainless steel braided EPDM lined flexible inlet hose assemblies incorporating ¾” captive nut end connections (inlet/outlet). All other models: Stainless steel braided EPDM lined flexible inlet hose assemblies incorporating 22mm push-fit end connections (inlet/outlet).
Marking:
Stuart Turner, model no., serial no, part no., pressure rating, Monsoon, manufacturer’s address and other technical information on adhesive label on body.
Installation Requirements:
R001 R007 R009 R415
Expiry date:
31/05/2029
Model:
46420: Monsoon S4.5 bar Single, 46419: Monsoon S3.0 bar Single, 46418: Monsoon S4.5 bar Twin, 46417: Monsoon S4.0 bar Twin, 46416: Monsoon S3.0 bar Twin, 46415: Monsoon S2.0 bar Twin, 46506: Monsoon S1.5 bar Twin, 44754: Monsoon S1.5 bar Twin, 46497: Monsoon S2.0 bar Single, 44424: Monsoon S1.5 bar Twin, 44423: Monsoon S2.0 bar Twin, 44422: Monsoon S2.0 bar Single, 44428: Monsoon S1.5 bar Twin EXIP, 46420ROI: Monsoon S4.5 bar Single, 46419ROI: Monsoon S3.0 bar Single, 46418ROI: Monsoon S4.5 bar Twin, 46417ROI: Monsoon S4.0 bar Twin, 46416ROI: Monsoon S3.0 bar Twin, 46415ROI: Monsoon S2.0 bar Twin, 46506ROI: Monsoon S1.5 bar Twin, 46497ROI: Monsoon S2.0 bar Single, 46420EXP: Monsoon S4.5 bar Single, 46419EXP: Monsoon S3.0 bar Single, 46418EXP: Monsoon S4.5 bar Twin, 46417EXP: Monsoon S4.0 bar Twin, 46416EXP: Monsoon S3.0 bar Twin, 46415EXP: Monsoon S2.0 bar Twin, 46506EXP: Monsoon S1.5 bar Twin, 46497EXP: Monsoon S2.0 bar Single.

Approval Holder:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company
Manufacturer:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 712 of 1306

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.