Directory Search Results

Print List

#2106021

Range of commercial washing machines with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The products are supplied with three ¾” x ¾” BSP (F) double check valve assemblies (suitable for backflow protection against Fluid Category 3) for installation on each inlet prior to a HDPE inlet hose with ¾” x ¾” captive nut end connections. Maximum working pressure 5.7 Bar. Maximum operating temperature 60°C.

Section:
2370 Washing Machine(s)
WRAS Approval Number:
2106021
Note:
This appliance incorporates a Fluid Category 5 backflow prevention device. The double check valve assemblies supplied with this product must be installed on all available inlets to maintain the validity of the WRAS approval. No detergents, softeners or other products are to be placed within the dispenser compartment that represent a risk greater than Fluid Category 3.
Size:
¾” BSP (F) (to double check valve assembly)
Marking:
Alliance Laundry logo, model, serial number, product info on label on back panel. Alliance laundry logo, model, serial number on label inside of door.
Installation Requirements:
R001 R160 R574
Expiry date:
30/06/2026
Model:
UCEXXX, SCEXXX, HCEXXX, ICEXXX & PCEXXX XXX denotes the drum capacity and can be replaced with the following digits representing lb’s: 020, 030, 040, 060, 080 & 100.

Approval Holder:
Alliance Laundry CE s.r.o
Company Name
Alliance Laundry CE s.r.o
Address
Místecká 1116, 742 58 Príbor
Country
Czech Republic
Phone
+420 556 768 885

View All Listings by this Company

Print This Approval


#2107011

Range of commercial dishwashers with flow controlled by a solenoid valve and discharged via a type AB air gap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only.

Section:
2390 Dishwasher(s)
Size:
¾” BSP (F)
Marking:
Colged on front panel. Colged, Eurotec, model, serial number, date of manufacture (DD/MM/YYYY) and other product info on label on side panel.
Installation Requirements:
R001 R574
Expiry date:
31/07/2026
Model:
TopTech 34-23TD (rack 40x40), TopTech 35-23TD (rack 45x45), TopTech 36-23TD (rack 50x50), TopTech 36L-23TD (rack 50x60), TopTech 38-23TD (rack 50x50 hood type), TopTech 39-23TD (rack 50x60 hood type).

Approval Holder:
Eurotec Srl div Colged
Company Name
Eurotec Srl div Colged
Address
Via Provinciale Romana 6-55010 Badia Pozzeveri Italy

View All Listings by this Company
Manufacturer:
Eurotec Srl div Colged
Company Name
Eurotec Srl div Colged
Address
Via Provinciale Romana 6-55010 Badia Pozzeveri Italy

View All Listings by this Company

Print This Approval


#2107322

Range of magnetic and electrolytic water conditioners with nickel plated copper bodies. Maximum working pressure 10 bar. MagnaScale2 model has a maximum operating temperature of 85°C. ElectroScale 2 models are for cold water use only.

Section:
2410 Water conditioners, de-scalers, phosphate dosing, magnetic, electrolytic and electronic
Size:
see model
Marking:
Adey Logo, model and batch number on adhesive label on body.
Installation Requirements:
R001 R120 R170
Expiry date:
31/07/2026
Model:
MagnaScale 2 (product code SR1-03-05230) – 15mm compression ElectroScale 2 (product code SR1-03-05607) - 1” BSPP (M). ElectroScale 2 (product code SR1-03-05214) – 15mm compression. Model added September 2021: ElectroScale 2 (product code SR1-03-05233): 22mm compression

Approval Holder:
Adey Innovation LLP
Company Name
Adey Innovation LLP
Address
Gloucester Road Cheltenham
Postcode
GL51 8NR

View All Listings by this Company

Print This Approval


#2110505

'Electrocoat BP 116'. Factory applied, black coloured bitumen paint. Apply as per manufacturer's technical data sheet, document number 'ECL/TDS/BP116' dated 10th January 2016. Cure for 30 minutes@55°C and then 10 hours@23°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5021 Bituminous Based Products
Section Subtitle:
Petroleum or asphaltic bitumen, NOT coal tar bitumen. Materials containing petroleum or asphaltic bitumen are not approved for use on water-retaining structures with large surface:volume ratio such as lining of pipes, cisterns or water storage tanks in contact with wholesome water, but may be acceptable for use where there is only a small surface area in contact with the water – e.g. taps, valves and pipe connectors.
WRAS Approval Number:
2110505
Expiry date:
31/10/2026

Approval Holder:
Electrosteel Castings Ltd.
Company Name
Electrosteel Castings Ltd.
Address
30 B.T. Road, PO Sukchar, District 24 Parganas (N) West Bengal, Kolkata - 700115
Country
743179

View All Listings by this Company

Print This Approval


#2202500

‘Karumel EX4412 Blue & Grey’. Factory applied, blue or grey coloured, epoxy resin based powder coating. Apply and cure as per manufacturer’s instructions reference 'PCA-21062901', issued August 2021. For use with water up to 85°C.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
2202500
Expiry date:
28/02/2027

Approval Holder:
KCC Corporation.
Company Name
KCC Corporation.

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 69 of 1769

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.