Directory Search Results

Print List

#240102709

Range of commercial washing machines with flow controlled by solenoid valves and discharged via type AB air gap assembly (verified by test - suitable for backflow protection against fluid category 5). The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5 Bar. Maximum operating temperature 60°C.

Section:
2370 Washing Machine(s)
Size:
Stainless steel braided silicone lined flexible hose assemblies with 3/4" BSP captive nut end connections.
Marking:
Renzacci on front panel, Renzacci, model, product info on data plate on rear panel
Installation Requirements:
R001 R160
Expiry date:
31/01/2029
Model:
HS9, HS11, HS13, HS18, HS24, HS28, HS35 LX16, LX16 E-SPEED, LX22, LX22 E-SPEED, LX35, LX35 E-SPEED SX11, SX11 E-SPEED, SX14, SX14 E-SPEED, SX16, SX16 E-SPEED, SX22, SX22 E-SPEED, SX35, SX35 E-SPEED WB25, WB35 LX55, LX55 E-SPEED HS, LX, LX E-SPEED, SX, SX E-SPEED models are single door with front loading WB models are double door barrier with side loading. Models added December 2024 HS55, HS90, LX55, LX E-SPEED, LX70, LX70 E-SPEED, LX120, SX55, SX55 E-SPEED, WB70

Approval Holder:
Renzacci SPA – Industria Lavatrici
Company Name
Renzacci SPA – Industria Lavatrici
Address
Via Morandi, 13 - 06012 Citta Di Castello PG Italy

View All Listings by this Company
Manufacturer:
Renzacci SPA – Industria Lavatrici
Company Name
Renzacci SPA – Industria Lavatrici
Address
Via Morandi, 13 - 06012 Citta Di Castello PG Italy

View All Listings by this Company

Print This Approval


#240102714

ClearScale Plus range of in-line water conditioners with stainless steel bodies and catalytic alloy core. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.

Section:
2410 Water conditioners, de-scalers, phosphate dosing, magnetic, electrolytic and electronic
Size:
Please refer to model.
Marking:
GRUNDFOS & model on adhesive label on body.
Installation Requirements:
R001 R120 R170
Expiry date:
31/01/2029
Model:
CCP15 - Clearscale plus Physical Water Conditioner - 1/2” CCP20 - Clearscale plus Physical Water Conditioner - 3/4” CCP25 - Clearscale plus Physical Water Conditioner - 1” CCP35 - Clearscale plus Physical Water Conditioner – 1 1/4” CCP40 - Clearscale plus Physical Water Conditioner – 1.5” CCP50 - Clearscale plus Physical Water Conditioner - 2” CCP65 – Clearscale plus Physical Water Conditioner- DN65 CCP80 - Clearscale plus Physical Water Conditioner - DN80 CCP100 - Clearscale plus Physical Water Conditioner - DN100 CCP125 - Clearscale plus Physical Water Conditioner - DN125 CCP150 - Clearscale plus Physical Water Conditioner - DN150

Approval Holder:
GRUNDFOS Water Treatment UK
Company Name
GRUNDFOS Water Treatment UK
Address
Halifax House, Coronation Road, Cressex Business Park, High Wycombe Buckinghamshire
Postcode
HP12 3SE
Country
United Kingdom

View All Listings by this Company

Print This Approval


#240202706

Range of in-line electrolytic scale inhibitors with copper bodies, for use with copper pipe manufactured to BS EN 1057 Maximum working pressure 20.0 bar. Cold water use only

Section:
2410 Water conditioners, de-scalers, phosphate dosing, magnetic, electrolytic and electronic
Marking:
Sentinal, SESI, model & technical information on body.
Installation Requirements:
R001 R120 R170
Expiry date:
28/02/2029
Model:
SESI15: 15mm compression. SESI22: 22mm compression.

Approval Holder:
Sentinel Performance Solutions Ltd.
Company Name
Sentinel Performance Solutions Ltd.
Address
7650 Daresbury Park, Daresbury, Warrington, Cheshire
Postcode
WA4 4BS

View All Listings by this Company

Print This Approval


#240202711

‘G5 C’ command centre providing chilled (filtered) water via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The inlet to the command centre incorporates two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum inlet supply pressure 5.0 bar. Cold water use only.

Section:
2420 Water Cooler(s) for drinking water
Size:
Stainless steel braided PEX lined flexible hose assembly incorporating a ½” captive nut end connection.
Marking:
Zip and HydroTap logo on body.
Installation Requirements:
R001 R009 R040 R150 R170
Expiry date:
28/02/2029
Proviso:
The product listed on this approval fall under the scope of the GB Biocidal Products Regulations (GB BPR) by either incorporating or producing an active substance and/or incorporating a treated article. The product(s) has/have been judged only against the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. The decision of the Scheme to list them is not to be taken as any guide as to their effectiveness to do the job for which the active substance and/or treated article is present. WRAS accepts no liability for the material meeting the requirements of the GB Biocidal Products Regulations.
Model:
Command Centre UK HydroTap Mains models: H50011000UK - G5 C100 M.

Approval Holder:
Zip Heaters UK Ltd T/A Zip Water UK
Company Name
Zip Heaters UK Ltd T/A Zip Water UK
Address
Trafalgar House, Trafalgar Business Park, Dereham
Postcode
NR19 1JG
Country
United Kingdom
Phone
0345 600 5005
General Email
sebastian.ducker@zipwater.co.uk

View All Listings by this Company

Print This Approval


#240202712

‘G5 CS’ command centre providing chilled or chilled sparkling water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The product incorporates a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The product is supplied with a filter cartridge. The inlet to the command centre incorporates two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum inlet supply pressure 5.0 bar. Cold water use only.

Section:
2420 Water Cooler(s) for drinking water
Size:
Stainless steel braided PEX lined flexible hose assembly incorporating a ½” captive nut end connection.
Marking:
Zip and HydroTap logo on body.
Installation Requirements:
R001 R009 R040 R160 R170 R415
Expiry date:
28/02/2029
Proviso:
The product listed on this approval fall under the scope of the GB Biocidal Products Regulations (GB BPR) by either incorporating or producing an active substance and/or incorporating a treated article. The product(s) has/have been judged only against the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. The decision of the Scheme to list them is not to be taken as any guide as to their effectiveness to do the job for which the active substance and/or treated article is present. WRAS accepts no liability for the material meeting the requirements of the GB Biocidal Products Regulations.
Model:
Command Centre UK HydroTap Mains model: H50065000UK - G5 CS100 M.

Approval Holder:
Zip Heaters UK Ltd T/A Zip Water UK
Company Name
Zip Heaters UK Ltd T/A Zip Water UK
Address
Trafalgar House, Trafalgar Business Park, Dereham
Postcode
NR19 1JG
Country
United Kingdom
Phone
0345 600 5005
General Email
sebastian.ducker@zipwater.co.uk

View All Listings by this Company

Print This Approval


#240255033

'ELECTROCOAT BP 1119'. Factory applied, black coloured Bituminous Paint. Apply as per manufacturer's TDS Document No: 'ECL/ TDS / BP-1119-Bituminous Paint', Issue Date '10-Aug-20', Version No: '01'. Cure for 12 minutes at 45°C, followed by 10 hours at 28°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5021 Bituminous Based Products
Section Subtitle:
Petroleum or asphaltic bitumen, NOT coal tar bitumen. Materials containing petroleum or asphaltic bitumen are not approved for use on water-retaining structures with large surface:volume ratio such as lining of pipes, cisterns or water storage tanks in contact with wholesome water, but may be acceptable for use where there is only a small surface area in contact with the water – e.g. taps, valves and pipe connectors.
WRAS Approval Number:
240255033
Expiry date:
28/02/2029

Approval Holder:
Electrosteel Castings Ltd.
Company Name
Electrosteel Castings Ltd.
Address
30 B.T. Road, PO Sukchar, District 24 Parganas (N) West Bengal, Kolkata - 700115
Country
743179

View All Listings by this Company

Print This Approval


#240255020

'KAJ1207'. Factory applied, blue coloured epoxy coating. Apply as per manufacturer's instructions 'file no. I01-KAJ1207' dated '2019.1.14'. Cure for 15 minutes@200°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
240255020
Expiry date:
28/02/2029

Approval Holder:
Shandong Xinke Powder Coatings Co. Ltd.
Company Name
Shandong Xinke Powder Coatings Co. Ltd.
Address
Lebushan Economic Development Zone, Weicheng District, Weifang City, Shandong
Country
China

View All Listings by this Company

Print This Approval


#240255022

'OBE-5378'. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's user instructions 'OBE-HG-001', edition 'A1', issue date '2023-OCT.-11st'. Cure for 10 minutes at 190°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
240255022
Expiry date:
28/02/2029

Approval Holder:
Wenzhou Oubang New Material Co., Ltd.
Company Name
Wenzhou Oubang New Material Co., Ltd.
Address
No.101 Yuhua Road, Dongmeng Industrial Zone, Wuniu Street, Yongjia County, Wenzhou City, Zhejiang Province
Country
China

View All Listings by this Company

Print This Approval


#2309548

'JM 9-2910'. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's instructions 'edition no.1', issue date 2019-9-5. Cure for 15 minutes@180°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
2309548
Expiry date:
30/09/2028

Approval Holder:
Saint-Gobain PAM(Jiangsu) Pipelines Technology Co., Ltd.
Company Name
Saint-Gobain PAM(Jiangsu) Pipelines Technology Co., Ltd.
Address
Building No.5, Zi Yun Wisdom Plaza, No. 19 Kazimen Avenue, Qinhuai District, Nanjing
Country
China

View All Listings by this Company

Print This Approval


#2104565

`WEY-Black, WEY-Red & WEY-Blue`. Factory applied epoxy coatings. Apply and cure as per manufacturer's TDS dated '24/11/2021'. For use with water up to 85°C.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
2104565
Expiry date:
30/04/2026

Approval Holder:
Saint-Gobain PAM(Jiangsu) Pipelines Technology Co., Ltd.
Company Name
Saint-Gobain PAM(Jiangsu) Pipelines Technology Co., Ltd.
Address
Building No.5, Zi Yun Wisdom Plaza, No. 19 Kazimen Avenue, Qinhuai District, Nanjing
Country
China

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 529 of 1043

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.