`SW EPDM`. Black coloured, extruded, EPDM hose. Shore hardness 85. Tested in-radii sizes between 0.75mm & 1.70mm. For use with water up to 85°C.
'Supercast PVC Waterstop Hydrofoil'. Blue coloured, extruded PVC waterstop. For use with water up to 23°C. These materials are for use in concrete reservoirs and similar structures, constructed in accordance with the design criteria of BS EN 1992 with respect to normal frequency of joints. The materials have been tested at a reduced surface area to volume ratio of 1000mm² per litre as specified in BS 6920: Part 1
'TamPur 150'. Site applied, Hydrophilic polyurethane foam which is an amber coloured liquid when unreacted and a pale yellow coloured, flexible foam material when cured. Mix TamPur 150 with water in a volumetric ratio of 1:1 and apply as per manufacturer’s TDS 'V1UK19 – 2019.4.25'. Cure for 24 hours at 7°C. For use with water up to 23°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval. These materials are for use in concrete reservoirs and similar structures, constructed in accordance with the design criteria of BS EN 1992-3:2006 (Design of concrete structures – Liquid retraining and containing structures) with respect to normal frequency of joints. The material has been tested at a reduced surface area to volume ratio of 1000mm² per litre.
'Durapipe FIP & Astore PVCu Clear Solvent Cement'. Clear, colourless solvent cements. Apply as per manufacturer's instructions and cure/dry for 24 hours@5°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Single hole, triple outlet (swivel) combination tap assembly (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with single lever operating member. Electronic controls allow the tap to dispense boiling, chilled or sparkling water. The vented models are supplied with a brass adaptor containing a plastic flow regulator and a combined EPDM washer and stainless-steel strainer, for installation on the mains cold water into the ceramic cartridge. They are also supplied with a stainless steel braided PEX lined flexible hose assembly and a stainless steel braided TPSiV lined flexible hose assembly both with ½” captive nut end connections for installation between the tap and a command centre, (which is not included as part of this approval). Maximum working pressure 5.0 bar. Maximum operating temperatures: Near boiling water circuit: 100°C. Ambient hot and cold (mixed) circuit: 65°C. Chilled/Chilled and sparkling circuit: Cold water use only.
Range of single hole, single outlet, electronically controlled tap assemblies (brass body – various finishes). The flow is controlled via a solenoid valve and activated by an infra-red sensor on the front of the spout. The spout outlet incorporates a plastic aerator. Models xxx.yyy.170E/W are supplied with a click clack waste. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of inlet control valves with DZR brass bodies incorporating a pressure reducing valve (set at 1.5, 1.8. 2.0, 2.1, 3.0 or 3.5 depending on model) and a pressure relief valve (set at 3.0, 3.5, 4.5, 5.0. 6.0 or 8.0 depending on model. All models incorporate a stainless-steel mesh and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model CWIC355040 comes supplied with a tundish. For use with copper pipe to BS EN 1057, PB pipe (with inserts) to BS EN 7291-2:2010 and PEX pipe (with inserts) to BS EN 7291-3:2010. Maximum working pressure 16.0. Maximum operating temperature of 25°C.
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by an electronically controlled flush valve. Maximum working pressure 10.0 bar. Cold water use only
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by electronic or manual actuation. Maximum working pressure 10.0 bar. Cold water use only
Page 52 of 101
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.