#2210041

WC direct flush valve consisting of a solenoid valve that controls the flow. The solenoid can be operated via a infrared sensor or a control button. The product incorporates a flow restrictor and supplied with 90,100 and 125 Ltr/min flow regulators. Maximum working pressure – 2.0 Bar Maximum operating temperature - 23 °C

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2210041
Note:
Solenoid is to be fitted where light is excluded. The flow rates for the flow regulators have not been verified by test.
Size:
Direct flush valve – 1” BSP (M) inlet and outlet.
Marking:
Wallgate on control box body Wallgate, size, flow arrow, on body.
Installation Requirements:
R001 R008 R120 R090 R410
Expiry date:
31/10/2027
Model:
DFKIT03-2 Direct Flush valve assembly.

Approval Holder:
Wallgate Ltd.
Company Name
Wallgate Ltd.
Address
Crow Lane, Salisbury
Postcode
SP2 0HB
Country
United Kingdom
Phone
01722 702058
General Email
jmarshall@wallgate.com

View All Listings by this Company
Manufacturer:
Wallgate Ltd.
Company Name
Wallgate Ltd.
Address
Crow Lane, Salisbury
Postcode
SP2 0HB
Country
United Kingdom
Phone
01722 702058
General Email
jmarshall@wallgate.com

View All Listings by this Company

Print This Approval


#2111389

Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C

Section:
1390 Heaters
Section Subtitle:
Electric, thermal storage, mains fed, open outlet.
WRAS Approval Number:
2111389
Size:
3/8” BSP
Marking:
INTU on front of machine Model and other tech info on adhesive label on body
Installation Requirements:
R001
Expiry date:
30/11/2026
Model:
2.4L,1500KW: SOLO ,LUXE, NEW SOLO & NEXUS 4L,2300KW: NEXUS PRO

Approval Holder:
INTU K Limited
Company Name
INTU K Limited
Address
Unit 6 BRK Enterprise Business Park, Runshaw Lane, Euxton
Postcode
PR7 6HD
Country
United Kingdom

View All Listings by this Company

Print This Approval


#2207374

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207374
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
Ideal heating printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2027
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
INDEPENDENT COMBI² C24 INDEPENDENT COMBI² C30 INDEPENDENT COMBI² C35

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company

Print This Approval


#2207375

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207375
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
I-MINI² printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2027
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
I-MINI²C24 I-MINI²C30 I-MINI²C35

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company

Print This Approval


#2209322

Brass fitting Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1478 Heater
Section Subtitle:
Combination boilers - accessories and components.
WRAS Approval Number:
2209322
Size:
10mm spigot (F) x 10mm spigot (M).
Marking:
Navien on body.
Installation Requirements:
R001
Expiry date:
30/09/2027
Model:
LL1466-04-09 Connector.

Approval Holder:
KD Navien
Company Name
KD Navien
Address
95, Suworam-gil Seotan-myeon Pyeongtaek-si Gyeonggi-do, Seoul
Country
Korea, Republic of

View All Listings by this Company
Manufacturer:
Zhejiang Double-Lin Valves Co. Ltd.
Company Name
Zhejiang Double-Lin Valves Co. Ltd.
Address
Yanpan Hardware Industrial Area, Ganjiang Town, Yuhuan
Country
China
Phone
+86-576-89915157

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 479 of 2085

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.