Range of stainless steel, PVC and nylon braided shower hoses (various finishes), incorporating PVC, EPDM or PEX liners and various end connections.
Range of manually operated, wall mounted, concealed blending valves with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of manually operated, wall mounted, concealed blending valves with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, exposed, thermostatic bar type shower mixing valves (chromium plated brass). The246PG model incorporates a 2-way ceramic disc diverter headwork with a dome type operating member controlling the flow between an overhead shower outlet and a shower handset. The 536PG model incorporates a quarter turn ceramic disc headwork with a dome type operating member controlling the flow to a shower handset. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. Both inlets incorporate a combined EPDM washer and stainless-steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Both products are supplied with a shower hose and handset, the B36264 model also includes a shower riser to an overhead shower outlet. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of adjustable T-type thermostatic mixing valves with brass bodies (chrome plated). Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, bar type, thermostatic shower blending valves (chromium plated brass), incorporating a ¼ turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, concealed, thermostatic shower valves with brass bodies and trim sets (various finishes - see models). Flow is controlled as follows (for operating members - see model): Single outlet models: ¼ turn ceramic disc headwork. Double Outlet Models without diverter: ¼ turn ceramic disc headworks. Double Outlet Models with diverter: 2-way ceramic disc diverter headwork. Triple Outlet Models with diverter: ¼ turn ceramic disc headwork and a 2-way ceramic disc diverter headwork. The temperature is controlled independently via a thermostatic cartridge with various operating members (see model) which incorporates a manual override button. The inlets incorporate a single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Specific models are supplied with a shower hose and handset (see models). Maximum working pressure 5.0 Bar Maximum operating temperature 60°C
Range of wafer and lugged type butterfly valves incorporating blue epoxy coated cast iron bodies, stainless steel discs and EPDM seat. The closing mechanism can be controlled by either a lever, gear or bore shaft. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Wall mounted, concealed, 2-way diverter valve (brass body and chrome trim set) with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of ‘Keraflo Aylesbury’ ceramic disc operated inlet valves with DZR brass bodies and ABS or copper outlets. K and KAX type float mechanism incorporate a polyethylene float and spirit level for installation. The KB type float mechanism is operated by a transfer of weight within the actuator tube, which is connected to a polyethylene buoy and weight via stainless steel chain. Maximum working pressure 10.0 bar. Cold water use only.
Manually adjustable pressure reducing valve, which incorporates a DZR brass body and an in-line double check valve assembly on the inlet (verified by test as suitable for backflow protection against Fluid Category 3). The outlet incorporates a shut-off valve. Maximum supply pressure 16.0 bar. Maximum outlet pressure between 1.5 bar and 6.0 bar. Maximum operating temperature 40°C.
Range of 5 way inlet control group assembly incorporating a DZR brass body incorporating a pressure reducing valve, with an adjustable outlet pressure range of either 3.0 bar, 3.5 bar, or 6.0 bar and a safety relief valve set at either 6.0 bar or 8.0bar (depending on model). The product incorporates an inline single check valve cartridge after the balanced cold take off, verified by test (suitable for backflow protection against Fluid Category 2). Maximum supply pressure 10.0 bar. Maximum operating temperature 85°C
Range of adjustable, pilot operated, pressure reducing control valves with black plastic bodies, EPDM diaphragm, EPDM ‘O’-rings and NBR seals. The products are supplied with auxiliary stainless-steel tubing, lever operated spherical valves, integral stainless-steel strainer, pilot valve and a quarter turn ceramic disc valve. Maximum inlet supply pressure 16.0 bar. Maximum outlet pressure 0 - 8.5 bar, 7.0 - 13.5 bar or 12.0 - 16.0 bar (see model). Maximum operating temperature 60°C.
Range of pre-set, spring loaded, angled pressure relief valves with plastic body and EPDM diaphragm. The valves are fitted with rotary type easing gear . For maximum working pressure please refer to model. Maximum operating temperature 99°C.
Range of pre-set pressure relief valves with bronze bodies and EPDM seating discs. Available with either a manual lever or dome type sealed cap. Pre-set relief pressures: DN15 and DN40 valves: 0.35 bar to 15.9 bar. DN20 valves: 0.35bar to 13.8bar. DN25, DN32 and DN50 valves: 0.35 bar to 12.5 bar. Maximum operating temperature 85°C.
Range of latching and normally closed (see model) solenoid valves with plastic bodies, NBR diaphragms and ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of lever operated spherical valves incorporating brass bodies (chrome plated), brass balls and PTFE seals. Maximum working pressure 40.0 bar. Maximum operating temperature 100°C.
Range of gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of 5 way inlet control group assemblies with a DZR brass body incorporating a pressure reducing valve, with an adjustable outlet pressure range between 2.7 and 3.3bar and a safety relief valve set at 8.0 bar. The product incorporates an inline single check valve cartridge after the balanced cold take off, verified by test (suitable for backflow protection against Fluid Category 2) and strainer on the inlet Maximum supply pressure 10.0 bar. Maximum operating temperature 85°C
Range OF JLA commercial washing machines with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The products are supplied with three ¾” x ¾” BSP (F) double check valve assemblies (suitable for backflow protection against Fluid Category 3) for installation on each inlet prior to a HDPE inlet hose with ¾” x ¾” captive nut end connections. Maximum working pressure 5.7 Bar. Maximum operating temperature 60°C.
Page 47 of 311
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.