#2110138

Shower handset with plastic bodies (chrome plated). Maximum operating temperature 65°C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
2110138
Note:
Open outlet use only
Size:
Handsets: ½" BSP (M). Overhead Showers: ½" BSP (F).
Marking:
DEVA on body.
Installation Requirements:
R001 R040
Expiry date:
31/10/2026
Model:
HANDSET P

Approval Holder:
Methven UK Limited
Company Name
Methven UK Limited
Address
3-3A Stone Cross Court Yew Tree Way Golborne Warrington
Postcode
WA3 3JE
Country
United Kingdom
Phone
0800 195 1602
General Email
raluca.olariu@uk.methven.com

View All Listings by this Company

Print This Approval


#2103345

Range of stainless steel, stainless steel with nylon or nylon braided, EPDM lined hose assemblies. Some models incorporate servicing valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1863 Tubes
Section Subtitle:
Elastomeric.
WRAS Approval Number:
2103345
Size:
DN 6 (denoted by 06) bore diameter availble with the following end connections: 01= F1/4 02= F1/4 elbow 03= M1/4 04= F3/8 05= F3/8 knurling nut 06= F3/8 insert without nut 07= F3/8 elbow 08= M3/8 09= F1/2 10= F1/2 wing nut 11= F1/2 elbow 12= M1/2 19= M8*(12-110) with single O-ring 20= M10*(12-110) with single O-ring; 21= M11*(12-110) with single O-ring 22= M12*(12-110) with single O-ring ; 23= M14*(12-110) with single O-ring 24= M15*(12-110) with single O-ring ; 26= F15 29=10mm Compression fitting 30=12mm compression fitting 31=15mm compression fitting 32=22mm compression fitting 33=15mm isolation valve 34=22mm isolation valve 35=10mm pushfit (used with copper tube manufactured to BS2871) 36=12mm pushfit (used with copper tube manufactured to BS2871) 37=15mm pushfit (used with copper tube manufactured to BS2871) 38=22mm pushfit (used with copper tube manufactured to BS2871) 39=10mm pushfit isolation valve (used with copper tube manufactured to BS2871) 40=12mm pushfit isolation valve (used with copper tube manufactured to BS2871) 41=15mm pushfit isolation valve (used with copper tube manufactured to BS2871) 42=22mm pushfit isolation valve (used with copper tube manufactured to BS2871) 45= M8*(12‐110) with double O‐ring 46= M10*(12‐110) with double O‐ring 47= M11*(12‐110) with double O‐ring 48= M12*(12‐110) with double O‐ring 49= M14*(12‐110) with double O‐ring 50= M15*(12‐110) with double O‐ring DN8 (denoted by 08) bore diameter availble with the following end connections: 03= M1/4 04= F3/8 05= F3/8 knurling nut 06= F3/8 insert without nut 07= F3/8 elbow 08= M3/8 09= F1/2 10= F1/2 wing nut 11= F1/2 elbow 12= M1/2 13= F3/4 14= F3/4 elbow 15= M3/419= M8*(12-110) with single O-ring 19= M8*(12-110) with single O-ring 20= M10*(12-110) with single O-ring; 21= M11*(12-110) with single O-ring 22= M12*(12-110) with single O-ring ; 23= M14*(12-110) with single O-ring 24= M15*(12-110) with single O-ring ; 25= M16*(12‐110) with single O‐ring 26= F15 27=15mm smooth tube 29=10mm Compression fitting 30=12mm compression fitting 31=15mm compression fitting 32=22mm compression fitting 33=15mm isolation valve 34=22mm isolation valve 35=10mm pushfit (used with copper tube manufactured to BS2871) 36=12mm pushfit (used with copper tube manufactured to BS2871) 37=15mm pushfit (used with copper tube manufactured to BS2871) 38=22mm pushfit (used with copper tube manufactured to BS2871) 39=10mm pushfit isolation valve (used with copper tube manufactured to BS2871) 40=12mm pushfit isolation valve (used with copper tube manufactured to BS2871) 41=15mm pushfit isolation valve (used with copper tube manufactured to BS2871) 42=22mm pushfit isolation valve (used with copper tube manufactured to BS2871) 43= F1/2 plastic nut 44= F3/4 plastic nut 45= M8*(12‐110) with double O‐ring 46= M10*(12‐110) with double O‐ring 47= M11*(12‐110) with double O‐ring 48= M12*(12‐110) with double O‐ring 49= M14*(12‐110) with double O‐ring 50= M15*(12‐110) with double O‐ring 51= M16*(12‐110) with double O‐ring DN10 (denoted by 10) bore diameter availble with the following end connections: 04= F3/8 05= F3/8 knurling nut 06= F3/8 insert without nut 07= F3/8 elbow 08= M3/8 09= F1/2 10= F1/2 wing nut 11= F1/2 elbow 12= M1/2 13= F3/4 14= F3/4 elbow 15= M3/419= M8*(12-110) with single O-ring 16= F1 17=F1 elbow 18= M1 20= M10*(12-110) with single O-ring; 21= M11*(12-110) with single O-ring 22= M12*(12-110) with single O-ring ; 23= M14*(12-110) with single O-ring 24= M15*(12-110) with single O-ring ; 25= M16*(12‐110) with single O‐ring 27=15mm smooth tube 28=22mm smooth tube 30=12mm compression fitting 31=15mm compression fitting 32=22mm compression fitting 33=15mm isolation valve 34=22mm isolation valve 35=10mm pushfit (used with copper tube manufactured to BS2871) 36=12mm pushfit (used with copper tube manufactured to BS2871) 37=15mm pushfit (used with copper tube manufactured to BS2871) 38=22mm pushfit (used with copper tube manufactured to BS2871) 39=10mm pushfit isolation valve (for use with copper tube) 40=12mm pushfit isolation valve (for use with copper tube) 41=15mm pushfit isolation valve (for use with copper tube) 42=22mm pushfit isolation valve (for use with copper tube) 43= F1/2 plastic nut 44= F3/4 plastic nut 46= M10*(12‐110) with double O‐ring 47= M11*(12‐110) with double O‐ring 48= M12*(12‐110) with double O‐ring 49= M14*(12‐110) with double O‐ring 50= M15*(12‐110) with double O‐ring 51= M16*(12‐110) with double O‐ring DN13 (denoted by 13) bore diameter availble with the following end connections: 04= F3/8 07= F3/8 elbow 08= M3/8 09= F1/2 10= F1/2 wing nut 11= F1/2 elbow 12= M1/2 13= F3/4 14= F3/4 elbow 15= M3/419= M8*(12-110) with single O-ring 16= F1 17=F1 elbow 18= M1 24= M15*(12-110) with single O-ring ; 25= M16*(12‐110) with single O‐ring 27=15mm smooth tube 28=22mm smooth tube 31=15mm compression fitting 32=22mm compression fitting 33=15mm isolation valve 34=22mm isolation valve 37=15mm pushfit (for use with copper tube) 38=22mm pushfit (for use with copper tube) 41=15mm pushfit isolation valve (for use with copper tube) 42=22mm pushfit isolation valve (for use with copper tube) 43= F1/2 plastic nut 44= F3/4 plastic nut 50= M15*(12‐110) with double O‐ring 51= M16*(12‐110) with double O‐ring DN19 (denoted by 09) bore diameter availble with the following end connections 13= F3/4 14= F3/4 elbow 15= M3/419= M8*(12-110) with single O-ring 16= F1 17=F1 elbow 18= M1 28=22mm smooth tube 32=22mm compression fitting 34=22mm isolation valve 38=22mm pushfit (used with copper tube manufactured to BS2871) 42=22mm pushfit isolation valve (used with copper tube manufactured to BS2871)
Marking:
MSL, WRAS and year of manufacture (YYYY) on ferrule.
Installation Requirements:
R001
Expiry date:
31/03/2026
Model:
BFFTCW-1510 BFFTCW-1510500 BFFTCW-1512 BFFTCW-1512500 BFFTCW-10D500 BFFTCW-10D900 BFFTCW-12D500 BFFTCW-12D900 BFFTCW-DD500 BFFTCW-DD900 BFFTCWIV-10D300 BFFTCWIV-12D300 BFFTCW-1515300 BFFTCW-1515500 BFFTCW-1515900 BFFTCW-15D300 BFFTCW-15D500 BFFTCW-15D900 BFFTCW-15E300 BFFTCW-15E500 BFFTCW-15E900 BFFTCW-2222300 BFFTCW-2222500 BFFTCW-22E300 BFFTCW-22E500 BFFTCW-22E900 BFFTCWIV-15D150 BFFTCWIV-15D300 BFFTCWIV-15D500 BFFTCWIV-15E300 BFFTCWIV-15E500 BFFTCWIV-22E30

Approval Holder:
Navigator MSL Ltd.
Company Name
Navigator MSL Ltd.
Address
Mill Road, Sharnbrook, Beds.
Postcode
MK44 1NP
Phone
01234 781234

View All Listings by this Company

Print This Approval


#2103039

'Hurricane' range of Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.

Section:
1890 Unvented Heating Apparatus
Size:
Primary circuit: 1” BSP (F) Secondary circuit: 1” BSP (F) Solar circuit: 1” BSP (F)
Marking:
Hurricane, Telford stainless and technical information including capacity and pressures on adhesive label on body.
Installation Requirements:
R001 R140 R360 R530
Expiry date:
31/03/2026
Model:
HURIXXX - Hurricane indirect single coil unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L 125 = 125L 150 = 150L 170 = 170L 200 = 200L 250 = 250L 300 = 300L 400 = 400L 500 = 500L HURIXXX/S - Hurricane indirect twin coil boiler & solar unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 170 = 170L 200 = 200L 250 = 250L 300 = 300L 400 = 400L 500 = 500L HURIXXX - Hurricane direct electric only unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L 125 = 125L 150 = 150L 170 = 170L 200 = 200L 250 = 250L 300 = 300L

Approval Holder:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF
Country
Wellington

View All Listings by this Company

Print This Approval


#2104925

Range of wall mounted thermostatic shower panels. Incorporates a single sequential headwork which controls the flow and temperature using a single lever operating member to a fixed riser rail shower hose and handset. The inlet incorporate single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with stainless steel strainers, flow restrictors and isolation valves. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.

Section:
2010 Shower Valves
Section Subtitle:
Shower valve(s) with thermostatic temperature control
WRAS Approval Number:
2104925
Size:
15mm compression
Marking:
Twyford Logo (Brand of Geberit) on operating member
Installation Requirements:
R001 R010 R040
Expiry date:
30/04/2026
Model:
SF1211CP

Approval Holder:
Geberit Sales Ltd.
Company Name
Geberit Sales Ltd.
Address
Geberit House, Edgehill Drive, Warwick
Postcode
CV34 6NH
Country
United Kingdom
Phone
01926516800
General Email
enquiries@geberit.co.uk

View All Listings by this Company

Print This Approval


#2106055

Range of wall mounted, concealed, thermostatic mixing vales with brass bodies and chrome plated trim sets, incorporating one or two quarter turn ceramic disc headworks with Single Lever operating members. Temperature is controlled independently via a thermostatic cartridge with various operating members (see model) which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.

Section:
2010 Shower Valves
Section Subtitle:
Shower valve(s) with thermostatic temperature control
WRAS Approval Number:
2106055
Note:
This approval does not include a shower hose and handset or overhead shower outlet.
Size:
¾” BSP (F)
Marking:
DEVA on trim set.
Installation Requirements:
R001 R010 R040
Expiry date:
30/06/2026
Model:
NTN1D & NTN2D,

Approval Holder:
Methven UK Limited
Company Name
Methven UK Limited
Address
3-3A Stone Cross Court Yew Tree Way Golborne Warrington
Postcode
WA3 3JE
Country
United Kingdom
Phone
0800 195 1602
General Email
raluca.olariu@uk.methven.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 410 of 699

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.