Directory Search Results

Print List

#2105318

Range of BS1212-4 diaphragm type inlet valves incorporating a plastic body for use in either side or bottom entry WC cisterns. The valves incorporate an up and over discharge, plastic arm and float. The inlet is fitted with a plastic flow regulator and strainer. Maximum working pressure 10 bar. Cold water use only.

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
2105318
Size:
½” BSP (M)
Marking:
Wirquin on arm. BS1212-4 on inlet body .
Installation Requirements:
R001 R550 R560
Expiry date:
31/05/2026
Model:
Aquasave Air, Inlet side entry range: 10120524 Aquasave Air, Inlet bottom entry range(cranked pedestal): 10120529 10120530 10120531 10120532 Aquasave Air, Inlet side entry range(straight pedestal): 10120525 10120526 10120527 10120528
Product Images

Approval Holder:
Wirquin Ltd
Company Name
Wirquin Ltd
Address
Unit 3 Alpha Court Thorne Doncaster
Postcode
DN8 5TZ
Country
United Kingdom
Phone
01302 312252
General Email
mick.kirby@wirquin.co.uk

View All Listings by this Company
Manufacturer:
Wirquin Ltd
Company Name
Wirquin Ltd
Address
Unit 3 Alpha Court Thorne Doncaster
Postcode
DN8 5TZ
Country
United Kingdom
Phone
01302 312252
General Email
mick.kirby@wirquin.co.uk

View All Listings by this Company

Print This Approval


#2106039

DC type pipe interrupter with a permanent atmospheric vent and DZR brass body and EPDM gasket. Maximum working pressure 3.0 bar. Maximum operating temperature 85°C.

Section:
0014 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2. Type DC - Pipe interrupter with permanent atmosphere vent. The device must be fitted with the lowest point of the air aperture not less than 150mm above the free discharge point, or spillover level of an appliance, and have no valve, flow restrictor or tap on its outlet.
WRAS Approval Number:
2106039
Size:
½” BSP (F) inlet/½” BSP (M) outlet
Marking:
TOF logo, date of manufacture (DD-MM-YYYY), flow arrow, CR on body
Installation Requirements:
R001
Expiry date:
30/06/2026
Model:
1000/551
Product Images

Approval Holder:
TOF SRL
Company Name
TOF SRL
Address
Via Dell'erica 16/18 28017 San Maurizio D'opaglio Italy

View All Listings by this Company
Manufacturer:
TOF SRL
Company Name
TOF SRL
Address
Via Dell'erica 16/18 28017 San Maurizio D'opaglio Italy

View All Listings by this Company

Print This Approval


#2106031

Spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and EPDM seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C

Section:
0026 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Check Valve Cartridge. The cartridges listed in this section are for factory installation only and are not suitable for on-site installation.
WRAS Approval Number:
2106031
Marking:
Korie, 1st 4 digits of product code, (e.g. OF14) and flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/06/2026
Model:
OF14200000 DN14, OF15200000 DN15, OF20200000 DN20, OF25200000 DN25.
Product Images

Approval Holder:
Yuhuan Korie Plastic Factory
Company Name
Yuhuan Korie Plastic Factory
Address
Technology Industry Functional Area, Chumen Village Yuhuan
Country
Zhejiang

View All Listings by this Company

Print This Approval


#2107309

Spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and NBR seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 bar & maximum operating temperature 65°C.

Section:
0026 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Check Valve Cartridge. The cartridges listed in this section are for factory installation only and are not suitable for on-site installation.
WRAS Approval Number:
2107309
Size:
see model
Marking:
Neoperl, flow arrow & size.
Installation Requirements:
R001
Expiry date:
31/07/2026
Model:
WV15 / DN15 – 31.4217.0 WV20 / DN20 – 31.4222.0 WV25 / DN25 – 31.4227.0 WV40 / DN40 – 31.4247.0
Product Images

Approval Holder:
Neoperl GmbH
Company Name
Neoperl GmbH
Address
Klosterrunstrasse 9-11, Müllheim
Postcode
D-79379
Country
Germany
Phone
+49 7631 188 374
General Email
DE.Approvals@neoperl.com

View All Listings by this Company
Manufacturer:
Neoperl GmbH
Company Name
Neoperl GmbH
Address
Klosterrunstrasse 9-11, Müllheim
Postcode
D-79379
Country
Germany
Phone
+49 7631 188 374
General Email
DE.Approvals@neoperl.com

View All Listings by this Company

Print This Approval


#2107311

Spring loaded resilient trim, in-line check valve cartridges incorporating plastic guides and stem, NBR or EPDM seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 Bar. Maximum operating temperature 65°C.

Section:
0026 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Check Valve Cartridge. The cartridges listed in this section are for factory installation only and are not suitable for on-site installation.
WRAS Approval Number:
2107311
Size:
DN 25
Marking:
Neoperl, flow arrow, size, WRAS on body.
Installation Requirements:
R001
Expiry date:
31/07/2026
Model:
NV25/DN25 31.4226.0. NV25/DN25-EPDM 31.0009.0
Product Images

Approval Holder:
Neoperl GmbH
Company Name
Neoperl GmbH
Address
Klosterrunstrasse 9-11, Müllheim
Postcode
D-79379
Country
Germany
Phone
+49 7631 188 374
General Email
DE.Approvals@neoperl.com

View All Listings by this Company
Manufacturer:
Neoperl GmbH
Company Name
Neoperl GmbH
Address
Klosterrunstrasse 9-11, Müllheim
Postcode
D-79379
Country
Germany
Phone
+49 7631 188 374
General Email
DE.Approvals@neoperl.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 375 of 2219

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.