'LARTON G/40 NAT.:0169F1'. Brown coloured, injection moulded PPS material. For use with water up to 85°C.
'3P764921 Pipe Spacer'. White coloured (opaque), injection moulded PP Pipe Spacer. For use with water up to 85°C.
'Cura External Leak Sealer (Part No: 27813)'. Clear silicone sealant. Apply as per manufacturer's TDS 'Version 1', dated '16/07/2025'. Cure for 96 hours@23°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'CarboStop 102/CarboStop 102 ACC'. Site applied, cream coloured (once applied) waterstop. Mix CarboStop 102 resin and CarboStop 102 ACC accelerator in a weight ratio of 20:0.4. Apply and cure as per manufacturer's Application Guide, revision date '19/09/25'. For use with water up to 23°C. This material is for use in concrete reservoirs and similar structures, constructed in accordance with the design criteria of BS EN 1992 with respect to normal frequency of joints. The material has been tested at a reduced surface area to volume ratio of 1000mm² per litre as specified in BS 6920: Part 1. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Weld-On 319 PVC Cement'. Clear Solvent Cement. Apply as per manufacturer's TDS '319-05-2024'. Cure for 4 hours@5°C. For use with water up to 23°C.
Range of bottom entry BS1212-4 (2016) delayed or non delayed action type float operated valves for WC flushing cisterns. Maximum working pressure 10.0 Bar, cold water use only.
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| OASISBM | Chrome | 1/2" BSP (F) | 8 bar | 65 °C | Utopia | Body | No | Solenoid | Not Applicable | Aerator |
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass) bodies. The flow is controlled via a solenoid valve activated via an infra-red sensor. The temperature is controlled independently via a thermostatic cartridge. The products incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets incorporate a stainless-steel strainer. The products are supplied with spherical valves for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of combined bath fillers and overflow waste assemblies with plastic bodies (various finishes). The outlet incorporates a plastic aerator. The products are supplied with a cable operated pop-up waste. Maximum operating temperature 60°C.
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| T43014 | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | On body | No | |||||
| T43084 | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | On body | No | |||||
| T43064 | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | On rear of body | No | |||||
| T43194 | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | On rear of body | No | |||||
| T44014 | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | On body | No | |||||
| T44054 | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | On body | No | |||||
| T44034 | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | On body | No | |||||
| T45004 | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | On body | No | |||||
| T45014 | BSP 1/2" (F) | 10 bar | 85 °C | Company logo | On operating member | No |


Page 369 of 446
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.