Range of copper press fittings with EPDM seals for use with EN1057 copper tube. The joints are achieved by means of a press tool. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
“Inox press-fitting system” range of stainless-steel press fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312 series 2). Joints are achieved using a press fitting tool. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 95°C
‘Buteline Polybutylene Plumbing System’ comprising of DZR brass or plastic fittings for use with Buteline polybutylene, EVOH barrier pipe (white or grey). Maximum working pressure 16 bar @ 23°C, 7.0 Bar @ 82°C.
Range of Gerpex press fittings for use with Alpert multilayer (Pe-rt/Al/Pe-rt) pipe. Alpert Multilyer Composite Pipe and Press Fitting system with brass press fittings with stainless steel sleeves incorporating EPDM o-rings. 16mm to 32 mm are LBP fittings and from 40mm to 63 mm are standard fittings. Joints are achieved via TH profile press tool. Maximum working pressure: 10bar Maximum working temperature: 95°c
Range of “Effast” ABS fittings for use with ABS pipe complying with BS EN 5391-2006. Maximum working pressure: 15 Bar. Maximum operating temperature: 23°C.
Range of DZR brass push fit fittings for use with copper pipe (manufactured to BS EN 1057), PB pipe (manufactured to BS7291-2) and PEX pipe (manufactured to BS7291-3). Maximum working pressures and operating temperatures: 12.5 @ 20°C, and 3.0 bar @ 92ºC.
Range of end feed copper solder fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of dual flush WC drop valves with an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
Range of stainless-steel plate heat exchanger assemblies incorporating single or twin pumps on the primary circuit. Maximum working pressure 10 Bar (UKE-8 models) or 6 bar (UKE-14 models).
Non-metallic materials and components comply with BS6920 at 85°C
Range of stainless-steel plate heat exchangers. Maximum working pressure 10 bar. Maximum operating temperature 90°C.
‘G5 BC’ range of command centres that provide instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCS’ range of command centres that provide instant near boiling, sparkling and chilled water (all filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products incorporate a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum inlet supply pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCU60 UV’ Command centre that provides instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combinations of solenoid valves and electronic pumps to the outlets. A UV unit is incorporated on the outlet from the chilled water tank. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a stainless-steel strainer. The primary circuit incorporates isolation valves on the flow and return. Maximum working pressures: DHW: 10.0 Bar CH:2.5 Bar Maximum operating Temperatures: DHW: 65.0°C CH: 85.0°C
‘Sonata’ range of water meters with plastic or brass/plastic bodies. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of inline water meters with blue epoxy coated cast iron body. Maximum working pressure 16.0 bar. Cold water use.
Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Hattersley M2000 range of flow measuring devices with stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Flow meter with stainless steel body. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
‘AQ tap’ water dispensing unit incorporating a brass solenoid and a flow sensor. The unit is operated using a smart card and credit system that allows the user to obtain a set amount of water. Maximum working pressure 3.0 bar. Cold water use only.
Page 306 of 566
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.