#2210057

Range of stainless steel indirect (single or twin coil), direct and heat pump unvented hot water storage cylinders. The heat pump models also incorporate a plate heat exchanger and a circulation pump. The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@90.0˚C. The products are supplied with an inlet control group consisting of an adjustable pressure reducing valve, adjustable in the range of 0.8 bar - 6.0 bar, but factory pre-set at 3.0 bar, a strainer, am expansion relief valve set at 6.0 bar and an approved single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The products are also supplied with an immersion heater, an expansion vessel (12, 19 or 24 litres depending on model) and a tundish. Maximum supply pressure to the inlet control group: 16.0 bar. Maximum working pressure: Secondary circuit: 5.5 Bar. Primary Circuit: 6.0 Bar (All models except for the Direct - DI prefix models). Maximum operating temperature 75°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2210057
Note:
R008 only applies to the HP prefix (Heat Pump) models. Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression or 28mm stub (Heat Pump models only).
Marking:
WARMFLOW logo, capacity, model name, maximum pressure, maximum temperature, date of manufacture (month/YYYY) and other technical info on adhesive label on body.
Installation Requirements:
R001 R008 R360
Expiry date:
31/10/2027
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°C and 45°C.
Model:
DI110UV - Direct Unvented water cylinder, DI140UV - Direct Unvented water cylinder, DI170UV - Direct Unvented water cylinder, DI200UV - Direct Unvented water cylinder, DI240UV - Direct Unvented water cylinder, DI290UV - Direct Unvented water cylinder. IN110UV - Indirect Unvented water cylinder, IN140UV - Indirect Unvented water cylinder, IN170UV - Indirect Unvented water cylinder, IN200UV - Indirect Unvented water cylinder, IN240UV - Indirect Unvented water cylinder, IN290UV - Indirect Unvented water cylinder. C140UV - Indirect Unvented water cylinder, C170UV - Indirect Unvented water cylinder, C200UV - Indirect Unvented water cylinder. TW170UV - Twin coil indirect Unvented water cylinder, TW200UV - Twin coil indirect Unvented water cylinder, TW240UV - Twin coil indirect Unvented water cylinder, TW290UV - Twin coil indirect Unvented water cylinder. HP170UV - Heat pump indirect unvented water cylinder, HP200UV - Heat pump indirect unvented water cylinder, HP240UV - Heat pump indirect unvented water cylinder, HP290UV - Heat pump indirect unvented water cylinder.

Approval Holder:
Warmflow Engineering Co. Ltd
Company Name
Warmflow Engineering Co. Ltd
Address
Lissue Industrial Estate, Moira Road, Lisburn Northern Ireland
Phone
02892 62 1515
General Email
sales@warmflow.co.uk

View All Listings by this Company
Manufacturer:
Warmflow Engineering Co. Ltd
Company Name
Warmflow Engineering Co. Ltd
Address
Lissue Industrial Estate, Moira Road, Lisburn Northern Ireland
Phone
02892 62 1515
General Email
sales@warmflow.co.uk

View All Listings by this Company

Print This Approval


#2301036

Range of stainless steel indirect unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 90°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit: 5.5 Bar Primary circuit: 3.0 Bar Solar circuit: 3.0 Bar

Non-metallic materials and components comply with BS6920 at 80°C

Section:
1890 Unvented Heating Apparatus
Size:
Secondary circuit: 22mm compression. Primary circuit: 28mm compression. Solar circuit: 22mm compression
Marking:
World Heat, model no., serial no., capacity, Max working pressure, expansion vessel pressure, all on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Expiry date:
31/01/2028
Model:
120ECOSLIMSS 150ECOSLIMSS 180ECOSLIMSS 210ECOSLIMSS 120ECOSLIMSOLSS 150ECOSLIMSOLSS 180ECOSLIMSOLSS 210ECOSLIMSOLSS 120TCSSFLOWSLIM 150TCSSFLOWSLIM 180TCSSFLOWSLIM 210TCSSFLOWSLIM 120DSSFLOWSLIM 150DSSFLOWSLIM 180DSSFLOWSLIM 210DSSFLOWSLIM 120ISSFLOWSLIM 150ISSFLOWSLIM 180ISSFLOWSLIM 210ISSFLOWSLIM

Approval Holder:
World heat Ltd
Company Name
World heat Ltd
Postcode
SK16 4RN
Country
United Kingdom
Phone
0161 343 8610
General Email
sales@whcylinders.co.uk

View All Listings by this Company
Manufacturer:
World heat Ltd
Company Name
World heat Ltd
Postcode
SK16 4RN
Country
United Kingdom
Phone
0161 343 8610
General Email
sales@whcylinders.co.uk

View All Listings by this Company

Print This Approval


#2303040

Range of indirect unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 6.0 bar Secondary: 5.5 bar

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1890 Unvented Heating Apparatus
Size:
Primary: 22mm Compression Secondary: 22mm compression
Marking:
Joule, Model name, capacity, max pressures, max temps and other technical information on label on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2028
Model:
TUMA-00150-LFC TUMA-00180-LFC TUMA-00210-LFC

Approval Holder:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company
Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#2301018

Range of 2, 3 and 4 port brushed chrome DZR brass manifolds incorporating a screw down isolation valve at each port and brass compression adaptors (MFIT100053). Pushfit outlets are for use with copper pipe (manufactured to EN1057), BPB pipe (manufactured to BS EN 7291-2:2010) and BPEX pipe (manufactured to BS EN 7291-3:2010). MANA500552, MANA500553 and MANA500554 models used in conjunction with the MFIT100053 brass compression adaptor on the outlets are for use with BPB pipe (manufactured to BS EN 7291-2:2010) and BPEX pipe (manufactured to BS EN 7291-3:2010). Maximum working pressure 10.0 bar at 82°C and 16.0 bar at 20°C.

Section:
1950 Manifolds
Section Subtitle:
Metal.
WRAS Approval Number:
2301018
Note:
The approval holder advises that this product must not be used on a central heating/primary circuit. The MFIT100053 brass compression adaptor is not approved in its own right.
Size:
See model.
Marking:
MANA prefix models: RWC on operating members, size and CR on body. JGMAN prefix models: John Guest (brand of Reliance Worldwide Corporation (UK) Ltd.) on operating members, size and CR on body.
Installation Requirements:
R001 R120
Expiry date:
31/01/2028
Model:
MANA500522 (2 Port Manifold): ¾” BSP (M) x 15mm push fit (2 Port Manifold). MANA500523 (3 Port Manifold): ¾” BSP (M) x 15mm push fit (3 Port Manifold). MANA500524 (4 Port Manifold): ¾” BSP (M) x 15mm push fit (4 Port Manifold). MANA500552 (2 Port Manifold): ¾” BSP (M) x ¾” BSP (M). MANA500553 (3 Port Manifold): ¾” BSP (M) x ¾” BSP (M). MANA500554 (4 Port Manifold): ¾” BSP (M) x ¾” BSP (M). JGMAN2 (2 Port Manifold): ¾” BSP (M) x 15mm push fit (2 Port Manifold). JGMAN3 (3 Port Manifold): ¾” BSP (M) x 15mm push fit (3 Port Manifold). JGMAN4 (4 Port Manifold): ¾” BSP (M) x 15mm push fit (4 Port Manifold). MFIT100053: EUROCONUS FITTING 15mm (brass compression adaptors), which must be used in conjunction with the MANA500552, MANA500553 and MANA500554 models.

Approval Holder:
Reliance Worldwide Corporation (UK)
Company Name
Reliance Worldwide Corporation (UK)
Address
Horton Road, West Drayton
Postcode
UB7 8JL
Country
United Kingdom
Phone
+44 7730 052060
General Email
PETER.LANCASTER@RWC.COM

View All Listings by this Company

Print This Approval


#2212911

Range of concealed electronic thermostatic shower valve with a plastic body, the flow is controlled via two motorised valves for hot and cold supply. Both inlets incorporate a plastic strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with isolation valves and wall mounted concealed diverter valves with plastic bodies. Maximum working pressure 7.0 Bar

Non-metallic materials and components comply with BS6920 at 65°C

Section:
2010 Shower Valves
Section Subtitle:
Shower valve(s) with thermostatic temperature control
WRAS Approval Number:
2212911
Size:
15mm spigot
Marking:
Valves - Aqualisa and product information on adhesive label. Isolation valves - DM logo, size & flow arrow on body. Diverter valves - AQUALISA and product info on body
Installation Requirements:
R001 R008 R040
Expiry date:
31/12/2027
Model:
HQD1015 HQD1017 HQD1019

Approval Holder:
Aqualisa Products Ltd.
Company Name
Aqualisa Products Ltd.
Address
Unit 6 The Flyers Way, Westerham, Kent
Postcode
TN6 1DE
Phone
07920 790367
General Email
tracey.jones@aqualisa.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 264 of 890

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.