Range of exposed bath fillers (brass body, various finishes) incorporating a ceramic cartridge headwork, controlling both flow and temperature with a single lever operating member. The products incorporate integrated overflow and click type pop-up waste systems. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of single hole, two single outlets (swivel) combination tap assemblies (brass bodies - various finishes). Incorporating ceramic cartridge headwork, single lever operating member controlling both flow and temperature to the spout and spring-loaded pull-down hose. The pull-down hose incorporates a hand spray with a self-closing trigger mechanism. The spout incorporates a ceramic disc headwork controlling the flow with a single lever operating member. The spout outlets incorporate plastic aerators. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of floor mounted spout outlets (stainless steel or brass body various finishes) incorporating a plastic aerator. Maximum working pressure: Open outlet use only Maximum operating temperature: 60.0°C
Chrome plated spout outlet. The spout outlet incorporates a plastic aerator. Maximum operating temperature 65°C.
Bath spout (brass body, various finishes - see model) incorporating a plastic aerator. Maximum operating temperature 60°C.
Range of indirectly heated stainless steel vented hot water storage cylinders. Maximum working pressures: Primary: 6.0 Bar Secondary: 6.0 Bar Maximum operating temperature 75.0°C
Range of expansion vessels with galvanised or stainless-steel inlets, incorporating butyl rubber diaphragms. The inlet incorporates a plastic strainer (all models, except for WD model). For maximum working pressures please refer to model.
Non-metallic materials and components comply with BS6920 at 70°C
Range of solder ring copper fittings for use with copper tube to EN 1057. The SRBTC015, SRBTC022, SRSTC015, SRSTC022 & SRSTC015 Models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring copper fittings for use with copper tube to BS EN 1057. Maximum working pressure 16 bar. Maximum working temperature 99°C
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Aquaflow range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of black polyethylene electrofusion fittings for use with PE100 pipe (manufactured to EN 12201-2). Please refer to model for maximum working pressures. For below ground and cold water use only.
Dual flush WC outlet valve incorporating an ABS body, operated via a push button assembly or a battery powered infra red sensor for either full or reduced flush. Cold water use only.
Range of automatic urinal flush valves with a plastic body. STD - Maximum working pressure 6.0 bar. LP - Maximum working pressure 0.5 bar. Cold water use only
Range of plate heat exchangers with stainless steel plates, for primary and secondary circulation. Models E040-2M-GB6 and R040-H2M-G6B are secondary use only. Maximum working pressure - R040-HNM-G6B range = 30.0 Bar and E040-NM-GB6 range = 20.0 Bar Maximum operating temperature - 99 °C
Alfa Laval range of copper brazed and stainless-steel fusion bonded, stainless steel heat exchangers in various sizes ranging from 4 plates to 300 plates. Maximum working pressures and temperatures: CB10, CB11, CB15, CB16, CB16AQ, CB18, CB18AQ & CB18DW: S1/S2 circuit: 5 Bar. S3/S4 circuit 10 Bar. Max working temperature 150°C. CB20 & CB20AQ: S1/S2 circuit: 16 Bar. S3/S4 circuit 16 Bar. Max working temperature 225°C. CB65, CB65AQ & CBH65: S1/S2 circuit: 18 Bar. S3/S4 circuit 37 Bar. Max working temperature 225°C. CBH16 & CBH18: S1/S2 circuit: 32 Bar. S3/S4 circuit 32 Bar. Max working temperature 150°C. Maximum operating temperatures detailed above are for primary circuits only, secondary circuits approved to 99oC. Models added March 2023: CBH30: 50 Bar (S1/S2/S3/S4) & 225.0°C, CBH112: 45 Bar (S1/S2) 51 Bar (S3/S4) & 225.0°C, CB30: 41 Bar (S1/S2/S3/S4) & 225.0°C, CB60: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB60AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CBH60: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB62: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB62AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CBH62: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB30AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB110: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB110AQ: 37 Bar (S1/S2/S3/S4) & 225.0°C, CBH110: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB112: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB112AQ: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB24: 29 Bar (S1/S2) 37 Bar (S3/S4) & 225.0°C, CB24AQ: 29 Bar (S1/S2) 37 Bar (S3/S4) & 225.0°C, ANTW66: 29.0 Bar (S1/S2/S3/S4), ANTW18: 23 Bar (S1/S2) 28 Bar (S3/S4) 225.0°C and RM11: 15 Bar (S3/S4) & 225.0°C. Maximum operating temperatures detailed above are for primary circuits only, secondary circuits approved to 99oC.
Electric, instantaneous, vented, mains water heaters with plastic housings and silicon gaskets. Model AQ5001353 incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum working pressure 1.5 bar.
Non-metallic materials and components comply with BS6920 at 98°C
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of static ultrasonic bulk water meters with stainless steel bodies and EPDM 'O'-rings. The products are supplied with two sets of optional (green) gaskets. Maximum operating temperature: Products marked T50: 65°C. Products marked T30: cold water use only.
Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Page 243 of 554
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.