Directory Search Results

Print List

#2212078

Range of shower heads with plastic bodies (various finishes), incorporating plastic strainer or flow restrictor and EPDM o rings with stainless-steel strainers on the inlets. Open outlet use only.

Non-metallic materials and components comply with BS6920 at 60°C

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
2212078
Size:
½” BSP (M)
Marking:
Hansgrohe on body.
Installation Requirements:
R001 R040
Expiry date:
31/12/2027
Model:
26 810 400 Hansgrohe Croma Select E Hand shower Multi 26 811 400 Hansgrohe Croma Select E Hand shower Multi EcoSmart 9 l/min 26 812 400 Hansgrohe Croma Select E Hand shower Vario 26 813 400 Hansgrohe Croma Select E Hand shower Vario EcoSmart 9 l/min 26 814 400 Hansgrohe Croma Select E Hand shower 1jet 26 815 400 Hansgrohe Croma Select E Hand shower 1jet EcoSmart 9 l/min 26 816 400 Hansgrohe Croma Select E Hand shower 1jet EcoSmart 7 l/min

Approval Holder:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company

Print This Approval


#2212331

Range of shower outlets with brass bodies (various finishes). Open outlet use only.

Non-metallic materials and components comply with BS6920 at 60°C

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
2212331
Size:
½” BSP (M)
Marking:
Axor on shower head
Installation Requirements:
R001 R040
Expiry date:
31/12/2027
Model:
AXOR once range: 48 790 xxx FixFit Showerpipe 48 791 xxx FixFit Showerset 48 792 xxx Fixfit Showerset (w/o handshower) 48 798 180 Basic Set FixFit Showerpipe

Approval Holder:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company
Manufacturer:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company

Print This Approval


#2104351

Bib taps incorporating either brass or DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1750 Taps
Section Subtitle:
Draw off bib tap(s)
WRAS Approval Number:
2104351
Size:
Please see model
Marking:
CPS, FLOW ARROW, SIZE & DATE OF MANUFACTURE ON BODY. DZR BRASS MODEL HAVE ‘CR’ ON body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
799299: ½” BSP (M).

Approval Holder:
The Highbourne Group, City Plumbing Supplies
Company Name
The Highbourne Group, City Plumbing Supplies
Address
Branch Support Centre Highbourne House Highbourne House Crick Northampton
Postcode
NN6 7SL
Country
United Kingdom
Phone
07342 078865
General Email
Lindsey.cocks-stevens@cityplumbing.co.uk

View All Listings by this Company

Print This Approval


#2211707

Range of stainless-steel braided EPDM lined flexible hose assemblies with various end connections. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1863 Tubes
Section Subtitle:
Elastomeric.
WRAS Approval Number:
2211707
Size:
see model
Marking:
PC, WRAS and year of manufacture on crimp connection Plumb Centre on end
Installation Requirements:
R001
Expiry date:
30/11/2027
Model:
½“ compression x ½" (F) BSP captive nut: 81891 300mm & 81832 500mm - DN10 81884 300mm & 8188 500mm - DN8 ¾“ compression x ¾" (F) BSP captive nut: 81879 500mm & 81885 300mm - DN13

Approval Holder:
Grafton Merchanting
Company Name
Grafton Merchanting
Address
Ashfield Naas Road Dublin 22 Ireland

View All Listings by this Company

Print This Approval


#2211041

Range of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The secondary circuit consists of a temperature and pressure relief valve set at 10.0 bar and 90°C and an alternative temperature and pressure relief valve also set at 10.0 bar and 90°C , an inlet control group consisting of a pressure reducing valve pre-set at 3.0 bar, an expansion relief valve set at 8.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum working pressure - Primary circuit: 6.0 bar & Secondary circuit: 7.5 bar Maximum operating temperature 85.0°C

Section:
1890 Unvented Heating Apparatus
Size:
22mm Compression on all circuits
Marking:
EVOCyle logo, max pressure, max temp, capacity and other technical information on label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2027
Model:
TTAMVD-0150LFB ThermaQ Evocyl Air 150 Direct TTAMVD-0180LFC ThermaQ Evocyl Air 180 Direct TTAMVD-0210LFC ThermaQ Evocyl Air 210 Direct TTAMVD-0250LFC ThermaQ Evocyl Air 250 Direct TTAMVD-0300LFC ThermaQ Evocyl Air 300 Direct TTAMVI-0150LFB ThermaQ Evocyl Air 150 Indirect TTAMVI-0180LFC ThermaQ Evocyl Air 180 Indirect TTAMVI-0210LFC ThermaQ Evocyl Air 210 Indirect TTAMVI-0250LFC ThermaQ Evocyl Air 250 Indirect TTAMVI-0300LFC ThermaQ Evocyl Air 300 Indirect

Approval Holder:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company
Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 239 of 890

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.