STH Ranges of brass crimp fit fittings incorporating EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057-2006). 74232, 74233, 74234, 74226, 74227, 74228, 74229 & 74231 models also incorporate a NBR gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
CB (CENTRE) Range of end feed copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The HLDPMFWT and HLDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The 30065321,30065313, 30065317,30465313,30065301, 30065305, 30065309, 30465301 & 30465305 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The 950513 & 950514 & 950501, 950503 & 953102 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper capillary, bronze or brass end feed fittings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Non-metallic materials and components comply with BS6920 at 99°C
Range of electric instantaneous water heaters. The DEX and DCX models incorporate a spherical ball valve on the inlet. The CEX and DEX models incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet incorporates a strainer. Maximum working pressure 10 bar (DEX models only) All other models open outlet. Maximum operating temperature: ES3/4/5 and Zip Hydrotap G4/G5 ranges – 65ºC. CEX, DEX and DCX ranges - 70°C.
‘Aquapoint APIII’ range of direct unvented under basin or over basin (wall mounted) electrically heated, enamel lined insulated steel storage cylinders. The cylinders are supplied with an expansion relief valve set at 6.0 bar. Maximum working pressure 5.5 bar. Maximum operating temperature 75°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Permanent filling/ pressurisation device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. In the event of a fall in system pressure, and only if the mains pressure is adequate, a solenoid valve operates to allow water into the system. At all other times a second solenoid valve drains the fill chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 6.0 Bar. Cold water use only.
Range of vertical multistage booster pumps, with stainless steel bodies and impellors. Maximum working pressure: See models Maximum working temperature 85°C.
Range of shower handsets with chrome plated ABS bodies incorporating NBR o rings. Maximum operating temperature 60°C.
Range of shower handsets (chrome plated brass), shower hoses, handset brackets and cover plates. The shower handset inlets incorporate stainless-steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60.0°C
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wholesome-water nickel plated brass manifolds for use with ‘Emmeti Gerpex RA’ Pexb/Al/Pexb Multilayer pipe and ‘Emmeti Alpert’ PERT/AL/PERT Multilayer Pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. Range of closed circuit use nickel plated brass manifolds for use with ‘JG Speedfit Layflat Polybutylene Barrier Pipe (models 10BPB & 15BPB)’. Maximum working pressure 3.0 bar. Maximum operating temperature 92°C.
Range of wall mounted, thermostatic blending valves (chrome plated brass bodies) incorporating quarter turn ceramic disc headwork with a single lever operating member. Temperature is independently controlled via a thermostatic cartridge with cross top operating members. Both inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Page 219 of 554
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.