Range of pillar taps (brass bodies – various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The products are supplied with metal backnuts. Maximum working pressure Bar 10.0 Maximum operating temperature 65°C.
Range of pillar taps (brass bodies – various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The products are supplied with metal backnuts. Maximum working pressure Bar 10.0 Maximum operating temperature 65°C.
Range of chromium plated stainless steel or brass interlocked shower hoses with an optional PVC outer layer. Incorporating either a PVC or TPE inner hose and EPDM gaskets. Maximum operating temperature 60°C.
Range of nylon braided flexible outlet hoses, incorporating an EPDM liner, EPDM ‘O’-rings and gaskets. Maximum operating temperature 85°C.
CAIO ranges of Indirect stainless steel insulated hot water storage cylinders with external expansion and copper pipework and fittings. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Range of wall mounted thermostatic bar shower mixers (chrome plated brass bodies), incorporating a 2-way manual diverter to control the flow with cube type operating members. The temperature is controlled independently via a thermostatic cartridge with cube type operating member that incorporates a manual override button. The inlets incorporate stainless-steel strainer and approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
Wall mounted thermostatic, bar type shower valves incorporating a non-rising spindle headwork controlling the flow. The temperature is controlled independently via a thermostatic cartridge that incorporates a manual override button. Both using either dome, cubed or single lever type operating members. The inlets incorporate stainless steel strainer washers and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is supplied with a shower hose, handset and flow regulator. Maximum working pressure 10.0 Bar Maximum operating temperature 65°C.
Wall mounted thermostatic bar type shower valves incorporating quarter turn ceramic disc headworks controlling the flow. The temperature is controlled independently via a thermostatic cartridge that incorporates a manual override button. Both using either dome, cubed or single lever type operating members. The inlets incorporate stainless steel strainer washers and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is supplied with shower hose, shower handset and flow regulator. Maximum working pressure 10.0 Bar Maximum operating temperature 65°C.
Wall mounted bar type thermostatic shower valve (chrome plated brass body) incorporating ceramic disc headworks that control flow to 2 outlets with dome type operating members. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is supplied with a shower hose, handset and flow regulator. Maximum working pressure 10.0 Bar Maximum operating temperature 65°C.
Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
T43014B | Chromed | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | |
T43084B | Chromed | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | |
T43014T | Chromed | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | |
T43084T | Chromed | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | |
T43034 | Chromed | BSP 3/4" (M) x BSP 1/2" (M) offset unions | 10 bar | 85 °C | Company logo | Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | |
T43064B | Chromed | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | |
T43194B | Chromed | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | |
T44014B | Chromed | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | |
T44054B | Chromed | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | |
T44014T | Chromed | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | |
T44054T | Chromed | BSP 3/4" (F) | 10 bar | 85 °C | Company logo | Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable |
Page 207 of 215
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.