Range of copper, bronze or DZR brass capillary solder ring fittings for use with copper pipe (manufactured to EN 1057). Maximum working pressure and operating temperatures: 8-28mm: 25.0 bar @ 30°C, 16.0 bar @ 100°C. 35-54mm: 25.0 bar @ 30°C, 16.0 bar @ 65°C and 10.0 bar @ 100°C.
‘SharkBite’ range of brass push fit fittings incorporating an EPDM ‘O’-ring. For use with the following pipes: JG Speedfit Layflat Polybutylene Barrier Pipe (JG BPB pipe manufactured to BS EN 7291-2:2010), 'BPEX' Barrier Pipe (JG BPEX pipe manufactured to BS EN 7291-3:2010), Polybutylene barrier pipe (manufactured to BS EN 7291-2:2010), PEX barrier pipe (manufactured to BS EN 7291-3:2010) and Copper pipe (manufactured to BS EN1057:2006). Maximum working pressures and operating temperatures: When used with Polybutylene barrier pipes (manufactured to BS EN 7291-2:2010) and PEX barrier pipes (manufactured to BS EN 7291-3:2010): 12.5 bar, cold water use only. 6.0 bar @ 95°C. When used with copper pipe (manufactured to BS EN1057:2006): 10mm sizes: Maximum working pressure 16.0 bar. Cold water use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. 15-22mm sizes: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C. 28mm size added April 2024: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of Redman fittings with mild steel bodies (polyamide coating) for use with Puriton II PE-AL-PE barrier pipe - For above and below ground and cold-water use. Jointing is achieved by hydraulic compression. Maximum working pressures: 12.5 Bar for 63mm SDR 11 PE80 pipe system, 10.0 Bar for 90mm to 180mm SDR 17 PE100 pipe system, 16.0 bar for 90mm to 180mm SDR 11 PE100 pipe system. Cold water use only.
Range of wall mounted, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel, pressure relief valve set at 3.0 bar and flow regulators. The inlets to both domestic hot water and primary circuits are controlled via screwdriver operated angled spherical valve. The primary circuit can be filled via a built in CAB device, that has been verified by test (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 80°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of water meter housings. The 4414-WMH-20 (threaded) model has a DZR brass body and a check valve cartridge on the inlet verified by test (suitable for backflow protection against Fluid Category 2). The 4414-WMH-1 & 4414-WMH-2 (compression) models have a brass body and an approved check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection. The compression models are for use with copper pipe (manufactured to EN 1057). Maximum operating pressure 16.0 bar. Maximum operating temperature 85°C.
Page 163 of 232
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.