Directory Search Results

Print List

#240502715

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240502715
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DHW: 15mm compression. CH: 22mm compression
Marking:
Range name on front cover, Model, Max pressure, Max temperature and product information on data plate on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2029
Model:
Models without a filing loop supplied: 0010016113 - Glow-worm ESSENTIAL 24c -A (H-GB) 0010016115 - Glow-worm ESSENTIAL 28c -A (H-GB) 0010016127 - Heatline CAPRIZ 2 24c -A (H-GB) 0010016128 - Heatline MONZA 2 24c -A (H-GB) 0010016129 - Heatline CAPRIZ 2 28c -A (H-GB) 0010016130 - Heatline MONZA 2 28c -A (H-GB) 0010021401 - Glow-worm EASICOM 3 24c -A (H-GB) 0010021402 - Glow-worm EASICOM 3 28c -A (H-GB) 0010020392 - Vaillant VUW 256/6-3 (H-GB) ecoFIT sustain 825 0010020393 - Vaillant VUW 306/6-3 (H-GB) ecoFIT sustain 830 0010020394 - Vaillant VUW 356/6-3 (H-GB) ecoFITsustain 835 Models with a filling loop supplied: 0010020389 - Vaillant VUW 256/6-3 (H-GB) ecoFIT pure 825 0010020390 - Vaillant VUW 306/6-3 (H-GB) ecoFIT pure 830 0010020391 - Vaillant VUW 356/6-3 (H-GB) ecoFIT pure 835 0010019813 - Vaillant VUW 306/6-3 (P-GB) ecoFIT pure 830 P 0010021204 - Glow-worm BETACOM 4 24c -A (H-GB) 0010021205 - Glow-worm BETACOM 4 30c -A (H-GB) 0010021404 - Glow-worm ULTIMATE 3 30c -A (H-GB) 0010021405 - Glow-worm ULTIMATE 3 35c -A (H-GB) 0010027591 - Glow-worm ENERGY 2 30c -A (P-GB) 0010035896 - Glow-worm ENERGY 7 25c (H-GB) 0010035897 - Glow-worm ENERGY 7 30c (H-GB) 0010035898 - Glow-worm ENERGY 7 35c (H-GB)

Approval Holder:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company

Print This Approval


#240204028

Range of water meter housings. The 4414-WMH-20 (threaded) model has a DZR brass body and a check valve cartridge on the inlet verified by test (suitable for backflow protection against Fluid Category 2). The 4414-WMH-1 & 4414-WMH-2 (compression) models have a brass body and an approved check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection. The compression models are for use with copper pipe (manufactured to EN 1057). Maximum operating pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1510 Water Meter Manifolds
Size:
see model
Marking:
Eagle and flow arrow on body. The 4414-WMH-20 model is also marked CR.
Installation Requirements:
R001
Expiry date:
28/02/2029
Model:
4414-WMH-1: 15mm compression, 4414-WMH-2: 22mm compression, 4414-WMH-20: ¾” BSP (F).

Approval Holder:
SCE Technology (Ningbo) Co., Ltd
Company Name
SCE Technology (Ningbo) Co., Ltd
Address
No.32 Yuanqu Road Cha Lu Industrial Zone Ninghai Ningbo Zhejiang
Country
China

View All Listings by this Company

Print This Approval


#240507701

`UPM3` range of single stage circulator pumps, with stainless steel or plastic bodies, plastic impellers, ceramic shafts and bearings, EPDM 'O'-rings and seals. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240507701
Size:
Stainless steel body models (N): 1" BSP (M) (retrospectively added June 2024), 1½” BSP (M) & 2” BSP (M). Composite (plastic) body models (CIL3): 1” BSP (M).
Marking:
Grundfos logo, Grundfos and model on top of pump housing. Production number, serial number, and technical information on side of pump housing. Stainless steel models also have a flow arrow on the body.
Installation Requirements:
R001
Expiry date:
31/05/2029
Model:
UPM3 **1-**2 N ***3 (GFNxx-). UPM3 **1-**2 - CIL3 ***3 (GFNxx-). Model added November 2024: ALPHA SOLAR 25-**2 N 180. Where: UPM3 & ALPHA SOLAR = pump type. For UPM3 these can also be: UPM3 HYBRID, UMP3 DHW, UPM3 K, UPM3 AUTO L UPM3 FLEX AS. **1 = size of inlet/outlet connection: N models – 25 = 1 ½”, 32 = 2”. CIL3 models – 15 = 1”. **2 = maximum head (dm): 20, 40, 50, 60, 70, 75 (all models). 105, 145 (stainless steel body models only). N = stainless steel body. CIL3 = composite (plastic) body. ***3 = port to port length in mm: 130 (all models) or 180 (ALPHA SOLAR 1½” model and 2” N models only).

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#240408701

Range of vertical submersible multistage pumps with either threaded or flanged end connections. Maximum operating temperature 23°C. Open outlet use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240408701
Size:
See models.
Marking:
Manufacturers logo and model on data plate.
Installation Requirements:
R001 R415
Expiry date:
30/04/2029
Model:
E6P – 3” BSP (F) E6RX – 2.1/2” BSP or 3” BSP (F) E6SX – 3” or 4” BSP (F) E6NVX - 2.1/2” BSPT, 3” BSPT or 4” BSPT (F) E8P – 5” BSP (F) E8R – 3” BSP (F) E8PX – 5” BSP (F) E8NVX – 5” BSPT (F) E10S – 150mm Ø flanged connection E10R – 4” BSP (F) E10PX – 6” BSPT (F) E12S - 150mm Ø flanged connection E12PX – 221mm Ø flanged connection E14S – 200 / 230mm Ø flanged connection E16S.P – 247mm Ø flanged connection E18S – 230mm Ø flanged connection E20S.P. – 260mm Ø flanged connection E22S.P. – 330mm Ø flanged connection

Approval Holder:
Caprari S.p.A
Company Name
Caprari S.p.A
Address
Via Emilia, Ovest 900, 41123 Modena
Country
Italy

View All Listings by this Company
Manufacturer:
Caprari S.p.A
Company Name
Caprari S.p.A
Address
Via Emilia, Ovest 900, 41123 Modena
Country
Italy

View All Listings by this Company

Print This Approval


#240202037

Range of shower panel units incorporating an overhead shower outlet. Flow is controlled via spring-loaded headworks using a push-button mechanism. The shower outlet connection incorporates an approved single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
240202037
Size:
½” BSP (M).
Marking:
Delabie on operating member.
Installation Requirements:
R001 R040
Expiry date:
28/02/2029
Model:
714700 714700DP.

Approval Holder:
Delabie UK Ltd.
Company Name
Delabie UK Ltd.
Address
18,rue du Maréchal Foch Friville Escarbotin
Postcode
80210
Country
France
General Email
sebastien.spriet@delabie.fr

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 137 of 267

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.