#240902075

Range of in-line water meters with plastic bodies. The inlet incorporates a plastic filter. Maximum working pressure; 16 Bar Maximum operating temperature 50°C

Section:
1505 Water Meters
WRAS Approval Number:
240902075
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
All models available in body lengths of 165, 170 and 190mm
Size:
1" BSP (M)
Marking:
Contazara, Model and technical information on faceplate. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
CZ4000- Q3=4

Approval Holder:
Contadores De Agua De Zaragoza S.A. (Contazara S.A.)
Company Name
Contadores De Agua De Zaragoza S.A. (Contazara S.A.)
Address
Carretera Castellon KM. 5 5 50720 Zaragoza Spain

View All Listings by this Company

Print This Approval


#241002027

Range of in-line water meters with brass bodies and plastic turbines. The inlets incorporate plastic filters, and the outlets incorporate non-return valves (not suitable for backflow protection). Maximum working pressure 16.0 Bar. Maximum operating temperature 65.0°C.

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M) ¾” BSP (M 1¼” BSP M, 1½” BSP M, 2” BSP
Marking:
Janz logo, model code and other info on meter box
Installation Requirements:
R001
Expiry date:
31/10/2029
Model:
Smartio DN15 Q3=2,5 R*** Smartio DN20 Q3=2,5 R*** Smartio DN20 Q3=4 R*** Models added August 2025: Smartio DN25 Q3=6,3 R*** Smartio DN32 Q3=10 R*** Smartio DN40 Q3=16 R*** Body lengths: DN25: 150mm/160mm/175mm/198mm*/220mm*/260mm* DN32: 150mm/160mm/200mm*/220mm*/260mm* DN40: 150mm/200mm/300mm* *It’s possible to put a non-return valve (NRV)
Product Images

Manufacturer:
Janz Contagem e Gestão de Fluidos, SA
Company Name
Janz Contagem e Gestão de Fluidos, SA
Address
Av. Infante D. Henrique nº 286 Lisboa
Postcode
1950-421
Country
Portugal
Phone
00351 21 831 6000

View All Listings by this Company

Print This Approval


#241002081

Range of in-line water meters with brass bodies and plastic turbines. The inlets incorporate plastic filters, and the outlets incorporate non-return valves (not suitable for backflow protection). Maximum working pressure 16.0 Bar. Maximum operating temperature 65.0°C.

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP(M), ¾” BS (M), 1¼” BSP(M), 1½” BSP(M) & 2” BSP(M).
Marking:
GWF, model code and other info on meter box
Installation Requirements:
R001
Expiry date:
31/10/2029
Model:
Sonico Nano DN15 Q3=2,5 R*** Sonico Nano DN20 Q3=2,5 R*** Sonico Nano DN20 Q3=4 R*** Body lengths DN15: 105 mm / 110mm / 115mm/ 134m / 142mm / 145mm / 160mm / 165mm / 170mm / 190mm / 220mm DN20: 105mm / 110mm / 115mm / 139mm /160mm / 165mm / 190mm / 220mm Models added October 2025: Sonico Nano DN25*** Sonico Nano DN32 *** Sonico Nano DN40*** Body lengths: DN25: 150mm/160mm/175mm/198mm*/220mm*/260mm* DN32: 150mm/160mm/200mm*/220mm*/260mm* DN40: 150mm/200mm/300mm*
Product Images

Approval Holder:
GWF AG
Company Name
GWF AG
Address
Obergrundstrasse 119 Lucerne
Postcode
6005
Country
Switzerland
Phone
+41 41 319 51 77
General Email
moritz.roettger@gwf.ch

View All Listings by this Company

Print This Approval


#240604003

Range of brass bodied differential angled bypass valves incorporating a spring-loaded adjustment facility. Maximum working pressure 10.0 bar. Maximum operating temperature 110°C.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
240604003
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
For close circuit use only.
Size:
See models.
Marking:
Caleffi logo, flow arrow, size moulded on body. Caleffi logo on cap.
Installation Requirements:
R001 R200
Expiry date:
30/04/2029
Model:
519700: 1 ¼" BSP (F), 519500: ¾” BSP (F), 519504: ¾” BSP (F), 519500 TH: ¾” BSP (F), 519500 TAK: ¾" BSP (F), 519505 IPG: ¾ BSP (F).

Approval Holder:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company
Manufacturer:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company

Print This Approval


#240902039

Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See model key
Marking:
VEGA logo date of manufacturer (YYYY), serial number and other technical data on body
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
PSC21.ab-c-d-N-f-g-h-I VEGAPULS C 21 PSC22.ab-c-d- N -f-g-h-I VEGAPULS C 22 PSC23.ab-c-d- N -f-g-h-I VEGAPULS C 23 PS21.ab-c-d- N -f-g-h-I VEGAPULS 21 PS31.ab-c-d- N -f-g-h-I VEGAPULS 31 KEY FOR VEGAPULS C 21 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; G Thread G1½ / G1 N Thread 1½NPT / 1NPT R Thread R1½ / R1 g = Cable material / Length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 22 ab = Explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignition proof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as: X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 23 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; F Thread G1 M Thread 1NPT Q Thread R1 g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS 21 / 31 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) AX without, for Ex-free area (CE, UKCA, RCM) VC ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) SC EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 TC CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 WC INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 c = Approved as overfill protection, which can be displayed as; X Without W With (WHG, VLAREM) d = Ship approval, which can be displayed as; X Without S With (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff/Pharmaceutical certificate, which can be displayed as X Without N With (NSF/ANSI/CAN 61) P With (NIH) F With (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable entry / connection, which can be displayed as; M M20x1.5 / Cable gland PA black (ø5-9mm), standard h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART i = Sensor setting via smartphone and VEGA Tools app X Without B With
Product Images

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company
Manufacturer:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 131 of 177

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.