#2010374

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2010374
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with Schedule 2 paragraph 24to the Water Supply (Water Fittings) Regulations 1999.
Size:
¾” BSP (F)
Marking:
Taconova Group AG and other technical information on control panel. Pressure, temperature, WRAS, type and other technical information on inside cover.
Installation Requirements:
R001 R140 R360
Expiry date:
31/10/2025
Model:
274.2411.696 HL3000E 10/26. 274.2491.696 HL3000E 10/26. 274.2611.696 HL3000E 10/40. 274.2691.696 HL3000E 10/40. 274.4411.696 HL3000E 16/26. 274.4491.696 HL3000E 16/26. 274.4611.696 HL3000E 16/40. 274.4691.696 HL3000E 16/40. 274.6411.696 HL3000E 26/26. 274.6491.696 HL3000E 26/26. 274.6611.696 HL3000E 26/40. 274.6691.696 HL3000E 26/40. 274.6711.696 HL3000E 26/50. 274.6791.696 HL3000E 26/50. Models added April 2025: 274.2411.696 TacoTherm Dual ZEPTO SMART CONNECT 10/26. 274.2491.696 TacoTherm Dual ZEPTO SMART CONNECT 10/26. 274.2611.696 TacoTherm Dual ZEPTO SMART CONNECT 10/40. 274.2691.696 TacoTherm Dual ZEPTO SMART CONNECT 10/40. 274.4411.696 TacoTherm Dual ZEPTO SMART CONNECT 16/26. 274.4491.696 TacoTherm Dual ZEPTO SMART CONNECT 16/26. 274.4611.696 TacoTherm Dual ZEPTO SMART CONNECT 16/40. 274.4691.696 TacoTherm Dual ZEPTO SMART CONNECT 16/40. 274.6411.696 TacoTherm Dual ZEPTO SMART CONNECT 26/26. 274.6491.696 TacoTherm Dual ZEPTO SMART CONNECT 26/26. 274.6611.696 TacoTherm Dual ZEPTO SMART CONNECT 26/40. 274.6691.696 TacoTherm Dual ZEPTO SMART CONNECT 26/40. 274.6711.696 TacoTherm Dual ZEPTO SMART CONNECT 26/50. 274.6791.696 TacoTherm Dual ZEPTO SMART CONNECT 26/50. Where final part of code denotes the number of plates on the heat exchanger, e.g. 10/26, 10 = number of plates on the space heating circuit, 26 = the number of plates on the domestic hot water circuit.
Product Images

Approval Holder:
Taconova UK Limited
Company Name
Taconova UK Limited
Address
Technology Centre | Advanced Manufacturing Park | Brunel Way Rotherham
Postcode
S60 5WG
Country
UK

View All Listings by this Company
Manufacturer:
Taconova Production s.r.o.
Company Name
Taconova Production s.r.o.
Address
Nova UL. C 627, CZ-38232 Velesin, Czech Republic

View All Listings by this Company

Print This Approval


#2010310

Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.

Section:
1350 Heat Exchangers
Size:
See model
Marking:
Uponor, model no, serial no & date of manufacture (DD.MM.YYYY) on inside cover.
Installation Requirements:
R001 R140 R360
Expiry date:
31/10/2025
Model:
Uponor Combi Port base XU: 1095642 15l/min 1095643 21l/min 1095644 29l/min Optional ball valve set 101802 for models 1095644 & 1095642 Uponor Combi Port PRO XU: 1095636 15l.min 1095637 21l/min Optional Ball valve set 1037536
Product Images

Approval Holder:
Uponor GmbH
Company Name
Uponor GmbH
Address
Industriestrasse 56, Hassfurt
Postcode
97437,
Country
Germany
Phone
0034916853600
General Email
mariaisabel.fernandez@uponor.com

View All Listings by this Company

Print This Approval


#2011003

Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C

Section:
1350 Heat Exchangers
Size:
See model
Marking:
SWEP, year of manufacture and technical information on adhesive label on body
Installation Requirements:
R001
Expiry date:
30/11/2025
Model:
Models X8T-SC-S Connection types: ½”, ¾” " External threaded male Number of plates minimum: 4 Number of plates maximum: 60 Models 10T-SC-M Connection types: 3/8” to 1 1/4 " External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 15T-SC-M Connection types: ½” to 1” External threaded male Number of plates minimum: 4 Number of plates maximum: 60 Models 16DW-SC-S Connection types: ½” to 1 1/4” External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 16DW-SC-M Connection types: ½” to 1 1/4” External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 220-SC-S Connection types: 1” to 2 1/2” External threaded male Number of plates minimum: 4 Number of plates maximum: 300 Models 320HT-SC-S Connection types: 1 ½” to 2 1/2” External threaded male Number of plates minimum: 4 Number of plates maximum: 300 Models 320LT-SC-S Connection types: 1 ½” to 3” External threaded male Number of plates minimum: 4 Number of plates maximum: 260
Product Images

Approval Holder:
SWEP International AB
Company Name
SWEP International AB
Address
Järvgatan 3B, Box 105, 26122 Landskrona
Country
Sweden

View All Listings by this Company
Manufacturer:
SWEP Slovakia s.r.o | SWEP Malaysia sdn Bhd
Company Name
SWEP Slovakia s.r.o | SWEP Malaysia sdn Bhd
Address

View All Listings by this Company

Print This Approval


#2011037

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2011037
Note:
A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Size:
½” BSP male inlet and outlet (DHW). ¾” BSP male inlet and outlet (CH).
Marking:
Lukey on adhesive label on front.
Installation Requirements:
R001 R140
Expiry date:
30/11/2025
Model:
Lukey solution HE (18kW CH & 26kW DHW). Lukey solution HE+ (18kW CH & 26kW DHW). Lukey solution HES+ (18kW CH & 26kW DHW). Lukey solution CBU (18kW CH & 26kW DHW). Beginning February 2021 the models will be named: Lukey 28 HE (18kW CH & 26kW DHW). Lukey 28 HE+ (18kW CH & 26kW DHW). Lukey 28 HES+ (18kW CH & 26kW DHW). Lukey 28 CBU (18kW CH & 26kW DHW).
Product Images

Approval Holder:
Lukey Cassette Boilers (UK) Ltd.
Company Name
Lukey Cassette Boilers (UK) Ltd.
Postcode
BH24 2BB

View All Listings by this Company
Manufacturer:
Lukey Cassette Boilers (UK) Ltd.
Company Name
Lukey Cassette Boilers (UK) Ltd.
Postcode
BH24 2BB

View All Listings by this Company

Print This Approval


#2010326

Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
1530 Miscellaneous Fittings
Size:
¾” BSP (M).
Marking:
Kemper, manufacturers address DN15 and other technical info on adhesive label. Kemper on front.
Installation Requirements:
R001 R520 R574
Expiry date:
31/10/2025
Model:
689 03 005 KHS Hygiene Flush Box PURE 689 03 006 KHS Hygiene Flush Box PURE 689 03 007 KHS Hygiene Flush Box PRO with flow sensor 689 03 008 KHS Hygiene Flush Box PRO with flow sensor 689 03 009 KHS Hygiene Flush Box LITE with flow sensor 689 03 010 KHS Hygiene Flush Box LITE with flow sensor
Product Images

Approval Holder:
Gebr. Kemper GmbH + Co. KG
Company Name
Gebr. Kemper GmbH + Co. KG
Address
Harkortstr. 5 57462 Olpe Germany
Phone
+49(0) 27618910
General Email
info@kemper-olpe.de

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 123 of 2243

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.