Range of press fittings (brass bodies - various finishes) with stainless steel press (‘TH’ profile) collars and EPDM O-rings for use with “VMA” range of PEX/AL/PEX multilayer pipe (for press fitting connections and compression for adaptor fittings only) or copper pipe manufactured to EN1057 (compression connections). Maximum operating temperature: 95°C. Maximum operating pressure: 10 bar.
Range of brass compression fittings for use with PEX pipe (manufactured to ISO 15875). Maximum working pressures: 16mm and 20mm sizes: 25.0 bar, 25mm sizes: 15.0 bar. Cold water use only.
Range of plastic, push-fit fittings (wall plate elbow, equal elbow, end stop, pipe insert, equal straight and equal tee) for use with MDPE pipe (manufactured to BS EN 12201), for above and below ground use. Copper adaptors are for use with PB pipe (manufactured to BS7291-2), PEX pipe (manufactured to BS7291-3) or Copper pipes (manufactured to BS EN 1057) and are for above ground use only. Maximum working pressure 16.0 bar. Cold water use only.
Range of copper or brass (see model) end feed fittings for use with copper tube (manufactured to BS EN1057). Tap connectors incorporate Fibre/NBR washers. Male and female union adaptors incorporate a silicone gasket. Maximum working pressure using hard solder: 8mm to 28mm, ½” to 1” BSP (F) or (M), 1” straight cylinder union and captive nut ½” to ¾”: 25.0 bar, 35mm to 54mm, 1¼” to 2” BSP (F) or (M): 16.0 bar. Maximum working pressure using silver brazing alloy EN1044: 66.7mm to 108mm, 2½” to 4” BSP (F) or (M): 16.0 bar, 133mm to 219mm: 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Electric instantaneous water heater with a plastic casing. Flow is controlled via a solenoid valve operated by an infrared sensor. Temperature is controlled by a dial on the front of the unit. The product incorporates a swivel arm outlet from the base. Maximum working pressure 3.0 bar. Maximum operating temperature 48˚C. Cold supply only.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of heat interface units incorporating a heat exchanger, flow sensor, spherical valve and shock arrestor. The heating circuit incorporates a pressure relief valve set at 3.0 bar. Maximum working pressure & operating temperature: Primary circuit is 16.0 bar & 90°C. Domestic hot water circuit is 10.0 bar & 65°C. Heating circuit is 2.5 bar & 80°C.
Range of ultrasonic water meters with brass bodies and plastic transducers. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meters with blue epoxy coated cast iron bodies. Maximum working pressure 16.0 Bar Maximum operating temperature 65.0°C
Range of inline water meters with brass bodies (blue or red epoxy coating). The inlet incorporates a plastic strainer. Maximum working pressure 16.0 Bar. Maximum operating temperature 85.0°C.
Page 1060 of 1132
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.