Unvented Heating Apparatus

Section Code 1890 :

Back To Directory Sections

#2203041

Mitsubishi EHWT17D-MHEDW indirectly heated stainless-steel unvented storage cylinder consisting of plate heat exchangers. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of an approved single check valve cartridge (verified by test as suitable for backflow protection against Fluid Category 2), strainer, a pressure relief valve set at 6.0 bar and pressure reducing valve set at 3.5 bar. The space heating circuit is factory fitted with a pressure relief valve fitted rated at 3.0 bar and an automatic air vent. A tundish, expansion vessel and filling loop are also supplied. Maximum secondary (wholesome) circuit working pressure: 5.5 bar. Maximum Space heating (primary) circuit working pressure: 2.5 bar. Maximum brine/ambient circuit working pressure: 9.5 bar. Maximum operating temperature 70°C

Section:
1890 Unvented Heating Apparatus
Size:
Secondary Circuit: 22mm compression. Space heating circuit: 28mm compression. Brine/Ambient circuit: 28mm compression.
Marking:
Company name and logo (Mitsubishi), max operating pressures, max operating temperature, capacity and other technical information on adhesive label on top of cylinder.
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2027
Model:
EHWT17D-MHEDW
Product Images

Approval Holder:
Mitsubishi Electric Air Conditioning Systems Europe Ltd.
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd.
Address
Nettlehill Road, Houston Industrial Estate, Livingston, Scotland
Postcode
EH54 5EQ
Phone
01506 - 44 55 00
General Email
mark.fletcher@m-ace.mee.com

View All Listings by this Company
Manufacturer:
Mitsubishi Electric Air Conditioning Systems Europe Ltd.
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd.
Address
Nettlehill Road, Houston Industrial Estate, Livingston, Scotland
Postcode
EH54 5EQ
Phone
01506 - 44 55 00
General Email
mark.fletcher@m-ace.mee.com

View All Listings by this Company

Print This Approval


#2204061

‘Comet’ combination units consisting of a cased and insulated stainless steel unvented hot water storage cylinder. The cylinder primary circuit is fitted with an in-line electrical heater which supplies the heat source to the secondary water via a stainless-steel coil, and the heat source to the central heating circuit directly. The cylinder is factory fitted with a temperature and pressure relief valve, pre-set at 7.0 bar 90 degrees. The unit is supplied with an inlet control group containing a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), pressure reducing valve set at 3.0 bar and an expansion relief set at 6.0 bar. An expansion vessel is factory fitted to both the secondary and primary circuits within and is positioned inside the casing. The primary circuit also incorporates a circulating pump and pressure relief valve which is set at 3.0 bar. Maximum secondary working pressure 5.5 Bar Maximum Primary working pressure 2.5 Bar Maximum operating temperature 65.0 °C

Section:
1890 Unvented Heating Apparatus
Size:
22 mm Compression
Marking:
Electric Heating company, max pressure, max temperature, capacity and other technical information on adhesive label on front door of the unit
Installation Requirements:
R001 R140 R360
Expiry date:
30/04/2027
Model:
EHCCOMCOMBI 9KW – 140 litres EHCCOMCCOMBI 12KW – 140 litres EHCOMCOMBI 14.4KW – 140 litres
Product Images

Approval Holder:
THE ELECTRIC HEATING COMPANY LTD
Company Name
THE ELECTRIC HEATING COMPANY LTD
Address
Block 5, Unit 40 Third Road Blantyre Ind Est GLASGOW
Postcode
G72 0UP
Country
United Kingdom
Phone
07986970466
General Email
chris@electric-heatingcompany.co.uk

View All Listings by this Company

Print This Approval


#2201019

Range of “MEGAAIR” bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added January 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
1890 Unvented Heating Apparatus
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression. Return circuit: 22mm compression.
Marking:
“Whitewolf” and “Megaair” Logo on front of cylinder. Product data label consisting of capacity, pressures and other technical information on front of body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/01/2027
Model:
WHITEWOLF MEGAAIR DIRECT UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 120 to 300 L): WWMxxxD WHITEWOLF MEGAAIR 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 120 to 300 L): WWMxxxI WHITEWOLF MEGAAIR 90 DIRECT SLIM UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 90 to 200 L): WWMSxxxD WHITEWOLF MEGAAIR 90 INDIRECT SLIM UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 90 to 200 L): WWMSxxxI Where xxx denotes the capacity in L and can be replaced by any of the following: 90, 120, 150, 170, 200, 250 or 300
Product Images

Approval Holder:
Whitewolf Cylinders Ltd
Company Name
Whitewolf Cylinders Ltd
Address
Unit 2, 30 Junction Business Park 119/121 Ouzlewell Green Lofthouse, West Yorkshire
Postcode
WF3 3QW
Country
United Kingdom
Phone
01132 822710
General Email
mail@whitewolfcylinders.com

View All Listings by this Company

Print This Approval


#2103036

Centerstore ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103036
Size:
22mm compression (Inlet Manifold)
Marking:
Centerstore (Trademark of Wolseley) on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2026
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
174767 CENTERSTORE 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174768 CENTERSTORE 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. 174769 CENTERSTORE 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174770 CENTERSTORE 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. 174771 CENTERSTORE 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER 174772 CENTERSTORE 200 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDE 174773 CENTERSTORE 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER 174774 CENTERSTORE 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER 174787 CENTERSTORE SLIM 120 INDIRECT HOT WATER STORAGE CYLINDER 174788 CENTERSTORE SLIM 150 INDIRECT HOT WATER STORAGE CYLINDER 174789 CENTERSTORE SLIM 170 INDIRECT HOT WATER STORAGE CYLINDER 174790 CENTERSTORE SLIM 200 INDIRECT HOT WATER STORAGE CYLINDER 174791 CENTERSTORE SLIM 120 DIRECT HOT WATER STORAGE CYLINDER 174792 CENTERSTORE SLIM 150 DIRECT HOT WATER STORAGE CYLINDER 174793 CENTERSTORE SLIM 170 DIRECT HOT WATER STORAGE CYLINDER 174794 CENTERSTORE SLIM 200 DIRECT HOT WATER STORAGE CYLINDER
Product Images

Approval Holder:
Wolseley UK
Company Name
Wolseley UK
Address
2 Kingmaker Court Warwick Technology Park Warwick
Postcode
CV34 6DY
Country
United Kingdom
Phone
01926705792
General Email
martin.lister@wolseley.co.uk

View All Listings by this Company

Print This Approval


#2201097

Range of CENTERSTORE AIR bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added March 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar. Maximum operating temperature 65°C.

Section:
1890 Unvented Heating Apparatus
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression. Return circuit: 22mm compression.
Marking:
Centerstore (Trademark of Wolseley) on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/01/2027
Model:
174775- CENTERSTORE AIR 120 INDIRECT UNVENTED HOT WATER CYLINDER 174776- CENTERSTORE AIR 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174777- CENTERSTORE AIR 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174778- CENTERSTORE AIR 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174779- CENTERSTORE AIR 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174780-WOLSELEY CENTERSTORE AIR 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. 174781- CENTERSTORE AIR 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174782- CENTERSTORE AIR 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174783- CENTERSTORE AIR 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174784- CENTERSTORE AIR 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174785- CENTERSTORE AIR 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174786- CENTERSTORE AIR 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174795- CENTERSTORE AIR SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174796- CENTERSTORE AIR SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174797- CENTERSTORE AIR SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174798- CENTERSTORE AIR SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER

Approval Holder:
Wolseley UK
Company Name
Wolseley UK
Address
2 Kingmaker Court Warwick Technology Park Warwick
Postcode
CV34 6DY
Country
United Kingdom
Phone
01926705792
General Email
martin.lister@wolseley.co.uk

View All Listings by this Company

Print This Approval


#2210052

Range of indirect unvented indoor heat pump storage cylinders which consist of a heat pump which sits on top of the tank and heats the hot water via refrigeration pipes which then heats the cylinder by being externally mounted around the cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressure 6.0 Bar (Secondary) Maximum operating temperature 55.0°C

Section:
1890 Unvented Heating Apparatus
Size:
¾” BSP (F)
Marking:
KERS logo, model name, capacity, max pressure, max temp and other technical information on label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/10/2027
Model:
KERS OA - W230 KERS MVHR - W230 KERS MVHR - W200 SL KERS OA -W200 SL KERS MVHR - W160 KERS OA - W160
Product Images

Approval Holder:
KERS INNOVATION UK LTD
Company Name
KERS INNOVATION UK LTD
Address
Unit 3 ALBERT STREET, HOLLINWOOD, OLDHAM, OL8 3QPCompany

View All Listings by this Company

Print This Approval


#2211041

Range of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The secondary circuit consists of a temperature and pressure relief valve set at 10.0 bar and 90°C and an alternative temperature and pressure relief valve also set at 10.0 bar and 90°C , an inlet control group consisting of a pressure reducing valve pre-set at 3.0 bar, an expansion relief valve set at 8.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum working pressure - Primary circuit: 6.0 bar & Secondary circuit: 7.5 bar Maximum operating temperature 85.0°C

Section:
1890 Unvented Heating Apparatus
Size:
22mm Compression on all circuits
Marking:
EVOCyle logo, max pressure, max temp, capacity and other technical information on label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2027
Model:
TTAMVD-0150LFB ThermaQ Evocyl Air 150 Direct TTAMVD-0180LFC ThermaQ Evocyl Air 180 Direct TTAMVD-0210LFC ThermaQ Evocyl Air 210 Direct TTAMVD-0250LFC ThermaQ Evocyl Air 250 Direct TTAMVD-0300LFC ThermaQ Evocyl Air 300 Direct TTAMVI-0150LFB ThermaQ Evocyl Air 150 Indirect TTAMVI-0180LFC ThermaQ Evocyl Air 180 Indirect TTAMVI-0210LFC ThermaQ Evocyl Air 210 Indirect TTAMVI-0250LFC ThermaQ Evocyl Air 250 Indirect TTAMVI-0300LFC ThermaQ Evocyl Air 300 Indirect
Product Images

Approval Holder:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company
Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#2210057

Range of stainless steel indirect (single or twin coil), direct and heat pump unvented hot water storage cylinders. The heat pump models also incorporate a plate heat exchanger and a circulation pump. The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@90.0˚C. The products are supplied with an inlet control group consisting of an adjustable pressure reducing valve, adjustable in the range of 0.8 bar - 6.0 bar, but factory pre-set at 3.0 bar, a strainer, am expansion relief valve set at 6.0 bar and an approved single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The products are also supplied with an immersion heater, an expansion vessel (12, 19 or 24 litres depending on model) and a tundish. Maximum supply pressure to the inlet control group: 16.0 bar. Maximum working pressure: Secondary circuit: 5.5 Bar. Primary Circuit: 6.0 Bar (All models except for the Direct - DI prefix models). Maximum operating temperature 75°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2210057
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression or 28mm stub (Heat Pump models only).
Marking:
WARMFLOW logo, capacity, model name, maximum pressure, maximum temperature, date of manufacture (month/YYYY) and other technical info on adhesive label on body.
Installation Requirements:
R001 R008 R360
Expiry date:
31/10/2027
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°C and 45°C.
Model:
DI110UV - Direct Unvented water cylinder, DI140UV - Direct Unvented water cylinder, DI170UV - Direct Unvented water cylinder, DI200UV - Direct Unvented water cylinder, DI240UV - Direct Unvented water cylinder, DI290UV - Direct Unvented water cylinder. IN110UV - Indirect Unvented water cylinder, IN140UV - Indirect Unvented water cylinder, IN170UV - Indirect Unvented water cylinder, IN200UV - Indirect Unvented water cylinder, IN240UV - Indirect Unvented water cylinder, IN290UV - Indirect Unvented water cylinder. C140UV - Indirect Unvented water cylinder, C170UV - Indirect Unvented water cylinder, C200UV - Indirect Unvented water cylinder. TW170UV - Twin coil indirect Unvented water cylinder, TW200UV - Twin coil indirect Unvented water cylinder, TW240UV - Twin coil indirect Unvented water cylinder, TW290UV - Twin coil indirect Unvented water cylinder. HP170UV - Heat pump indirect unvented water cylinder, HP200UV - Heat pump indirect unvented water cylinder, HP240UV - Heat pump indirect unvented water cylinder, HP290UV - Heat pump indirect unvented water cylinder.
Product Images

Approval Holder:
Warmflow Engineering Co. Ltd
Company Name
Warmflow Engineering Co. Ltd
Address
Lissue Industrial Estate, Moira Road, Lisburn Northern Ireland
Phone
02892 62 1515
General Email
sales@warmflow.co.uk

View All Listings by this Company
Manufacturer:
Warmflow Engineering Co. Ltd
Company Name
Warmflow Engineering Co. Ltd
Address
Lissue Industrial Estate, Moira Road, Lisburn Northern Ireland
Phone
02892 62 1515
General Email
sales@warmflow.co.uk

View All Listings by this Company

Print This Approval


#2301036

Range of stainless steel indirect unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 90°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit: 5.5 Bar Primary circuit: 3.0 Bar Solar circuit: 3.0 Bar

Non-metallic materials and components comply with BS6920 at 80°C

Section:
1890 Unvented Heating Apparatus
Size:
Secondary circuit: 22mm compression. Primary circuit: 28mm compression. Solar circuit: 22mm compression
Marking:
World Heat, model no., serial no., capacity, Max working pressure, expansion vessel pressure, all on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Expiry date:
31/01/2028
Model:
120ECOSLIMSS 150ECOSLIMSS 180ECOSLIMSS 210ECOSLIMSS 120ECOSLIMSOLSS 150ECOSLIMSOLSS 180ECOSLIMSOLSS 210ECOSLIMSOLSS 120TCSSFLOWSLIM 150TCSSFLOWSLIM 180TCSSFLOWSLIM 210TCSSFLOWSLIM 120DSSFLOWSLIM 150DSSFLOWSLIM 180DSSFLOWSLIM 210DSSFLOWSLIM 120ISSFLOWSLIM 150ISSFLOWSLIM 180ISSFLOWSLIM 210ISSFLOWSLIM
Product Images

Approval Holder:
World heat Ltd
Company Name
World heat Ltd
Postcode
SK16 4RN
Country
United Kingdom
Phone
0161 343 8610
General Email
sales@whcylinders.co.uk

View All Listings by this Company
Manufacturer:
World heat Ltd
Company Name
World heat Ltd
Postcode
SK16 4RN
Country
United Kingdom
Phone
0161 343 8610
General Email
sales@whcylinders.co.uk

View All Listings by this Company

Print This Approval


#2303040

Range of indirect unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 6.0 bar Secondary: 5.5 bar

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1890 Unvented Heating Apparatus
Size:
Primary: 22mm Compression Secondary: 22mm compression
Marking:
Joule, Model name, capacity, max pressures, max temps and other technical information on label on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2028
Model:
TUMA-00150-LFC TUMA-00180-LFC TUMA-00210-LFC
Product Images

Approval Holder:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company
Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#2103039

'Hurricane' range of Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.

Section:
1890 Unvented Heating Apparatus
Size:
Primary circuit: 1” BSP (F) Secondary circuit: 1” BSP (F) Solar circuit: 1” BSP (F)
Marking:
Hurricane, Telford stainless and technical information including capacity and pressures on adhesive label on body.
Installation Requirements:
R001 R140 R360 R530
Expiry date:
31/03/2026
Model:
HURIXXX - Hurricane indirect single coil unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L 125 = 125L 150 = 150L 170 = 170L 200 = 200L 250 = 250L 300 = 300L 400 = 400L 500 = 500L HURIXXX/S - Hurricane indirect twin coil boiler & solar unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 170 = 170L 200 = 200L 250 = 250L 300 = 300L 400 = 400L 500 = 500L HURIXXX - Hurricane direct electric only unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L 125 = 125L 150 = 150L 170 = 170L 200 = 200L 250 = 250L 300 = 300L

Approval Holder:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF
Country
Wellington

View All Listings by this Company

Print This Approval


#2305339

Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. Fitted with a Caleffi 309463 GLD temperature and pressure relief valve sat at 6 bar & 90°C, and supplied with an inlet control group consisting of in-line pressure reducing valve (Caleffi set at 3 bar) and pressure relief valve (Caleffi CWIC200055) set at 4.5 bar, and incorporates a stainless-steel mesh and an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2), expansion vessel and filling loop. Maximum working pressure 4.4 bar. Maximum operating temperature 99°C.

Section:
1890 Unvented Heating Apparatus
Size:
28mm compression.
Marking:
Manufacturers name, address, date of manufacturer, capacity, model no, serial no, pressure and technical information.
Installation Requirements:
R001 R140 R360 R511 R530
Expiry date:
31/05/2028
Model:
IDEPLUHP150PPSZ & IDEPLUHP180PPSZ: 550mm diameter; 150, 180; litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Single zone. IDEPLUHP150PPSZSL & IDEPLUHP180PPSZSL: 475mm diameter; 150, 180, litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP210PPDZ, IDEPLUHP250PPDZ & IDEPLUHP300PPDZ: 550mm diameter; 210, 250, 300 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Two zone. IDEPLUHP210PPDZSL: 475mm diameter; 210 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Two zone. IDEPLUHP180DUOPPSZ & IDEPLUHP210DUOPPSZ: 550mm diameter 180, 210, litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP250DUOPPSZ & IDEPLUHP300DUOPPSZ: 630mm diameter 250, 300 litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP180DUOPPDZ & IDEPLUHP210DUOPPDZ: 550mm diameter 180, 210, litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; two zone. IDEPLUHP250DUOPPDZ & IDEPLUHP300DUOPPDZ: 630mm diameter 250, 300 litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; two zone. IDEPLUHP400: 630mm diameter; 400 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14 kW. IDEPLU090MB: 630mm diameter; 90 litre; buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; and any cylinder without a buffer.
Product Images

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company

Print This Approval


#2310324

Air Source Hot Water Cylinder range of cased and insulated, unvented hot water storage cylinders (enamelled steel) of the package type incorporating heat pump module. The DHW circuit includes a factory fitted temperature & pressure relief valve (Caleffi) set at 7 bar and 95˚C . The safety kit incorporates a pressure reducing valve (Caleffi) set at 3.5 bar, strainer, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2 and an expansion valve (Caleffi) set at 6 bar, expansion vessel (Reflex) and a tundish (Caleffi). The temperature of the hot water is controlled by a factory fitted manual control (set at 60˚C) and a high pressure switch positioned on the heat pump module (maximum temperature 65˚C) The cylinders are factory fitted with standard dual control immersion heater. Immersion heater incorporate control and manual resetting thermostats (maximum 89˚C). Maximum working pressure 5.5 Bar Maximum operating temperature 75°C. Maximum supply pressure to the pressure reducing valve is 12 bar. Maximum working pressure of the primary circuit 3.5 bar. Maximum operating temperature 80°C.

Section:
1890 Unvented Heating Apparatus
Size:
¾” BSP (F) ¾” BSP (M) connections provided.
Marking:
Curv printed on body. Curv, model, pressure ratings, volume and other tech info on adhesive label.
Installation Requirements:
R001 R140
Expiry date:
31/10/2028
Model:
HP80M5 HP110M5 HP150M5 HP200M3 HP250M3 Models added September 2024 HP200M7 HP250M7 HP150M8 HP110M8 HP80M8
Product Images

Approval Holder:
Curv 360 Ltd
Company Name
Curv 360 Ltd
Address
Unit 1 Lakes Court Newborough Road Burton-On-Trent
Postcode
DE13 9PD
Country
United Kingdom
Phone
07572 066 618
General Email
john.bell@projectcurv.co.uk

View All Listings by this Company

Print This Approval


#240202703

Range of indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and an approved check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 3.0 Bar Secondary: 5.5 Bar Solar: 3.0 bar Maximum operating temperature 90.0°C

Section:
1890 Unvented Heating Apparatus
Size:
Primary circuit: 28mm compression Secondary circuit: 22mm compression Solar circuit: 22mm compression
Marking:
World Heat Ltd logo, model number, capacity, temperature and pressure and other technical information on adhesive label on cylinder.
Installation Requirements:
R001 R140 R360
Expiry date:
28/02/2029
Model:
120CLIMACYLSS2 – 120 Litre 550mm diameter with heat pump coil DN25 x 14M 150CLIMACYLSS2 – 150 Litre 550mm diameter with heat pump coil DN25 x 14M 180CLIMACYLSS3 – 180 Litre 550mm diameter with heat pump coil DN25 x 14M 210CLIMACYLSS3 – 210 Litre 550mm diameter with heat pump coil DN32 x 13M 250CLIMACYLSS3 – 250 Litre 550mm diameter with heat pump coil DN32 x 13M 300CLIMACYLSS3 – 300 Litre 550mm diameter with heat pump coil DN32 x 13M 120CLIMACYLSSTC12 – 120L 550mm diameter with heat pump & solar coils DN25 x 14M & DN20 x 7M 150CLIMACYLSSTC12 – 150L 550mm diameter with heat pump and solar coils DN25 x 14M & DN20 x 7M 180CLIMACYLSSTC13 – 180L 550mm diameter with heat pump and solar coils DN25 x 14M & DN20 x 7M 210CLIMACYLSSTC13 – 210L 550mm diameter with heat pump and solar coils DN32 x 13M 250CLIMACYLSSTC13 – 250L 550mm diameter with heat pump and solar coils DN32 x 13M 300CLIMACYLSSTC13 – 300L 550mm diameter with heat pump and solar coils DN32 x 13M 120TCSFLOW – 120L 550mm diameter with boiler and solar coils 2 x DN20 x 7M 150TCSFLOW – 150L 550mm diameter with boiler and solar coils DN20 x 8M & DN20 x 7M 180TCSFLOW – 180L 550mm diameter with boiler and solar coils DN20 x 8M & DN20 x 7M 210TCSFLOW – 210L 550mm diameter with boiler and solar coils DN25 x 10M & DN20 x 7M 250TCSFLOW – 250L 550mm diameter with boiler and solar coils DN25 x 10M & DN20 x 7M 300TCSFLOW – 300L 550mm diameter with boiler and solar coils DN25 x 14M & DN20 x 7M 120DSSFLOW – 120L 550mm diameter direct with no coils and 2 x immersion heaters 150DSSFLOW – 150L 550mm diameter direct with no coils and 2 x immersion heaters 180DSSFLOW – 180L 550mm diameter direct with no coils and 2 x immersion heaters 210DSSFLOW – 210L 550mm diameter direct with no coils and 2 x immersion heaters 250DSSFLOW – 250L 550mm diameter direct with no coils and 2 x immersion heaters 300DSSFLOW – 300L 550mm diameter direct with no coils and 2 x immersion heaters 120ISSFLOW – 120L 550mm diameter with boiler coil DN20 x 7M 150ISSFLOW – 150L 550mm diameter with boiler coil DN20 x 8M 180ISSFLOW – 180L 550mm diameter with boiler coil DN20 x 8M 210ISSFLOW – 210L 550mm diameter with boiler coil DN25 x 10M 250ISSFLOW – 250L 550mm diameter with boiler coil DN25 x 10M 300ISSFLOW – 300L 550mm diameter with boiler coil DN25 x 14M
Product Images

Approval Holder:
World heat Ltd
Company Name
World heat Ltd
Postcode
SK16 4RN
Country
United Kingdom
Phone
0161 343 8610
General Email
sales@whcylinders.co.uk

View All Listings by this Company
Manufacturer:
World heat Ltd
Company Name
World heat Ltd
Postcode
SK16 4RN
Country
United Kingdom
Phone
0161 343 8610
General Email
sales@whcylinders.co.uk

View All Listings by this Company

Print This Approval


#2312325

Range of cased and insulated stainless steel unvented water storage heaters. The DHW circuit includes a factory fitted combined temperature and pressure relief valve set at 6.0 bar and 90˚C. The product can be supplied with two possible safety kits (inlet control groups). One includes a pressure reducing valve adjustable between 1.5-6.0 bar, (but set at 3.0 bar), a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and a pressure relief valve pre-set at 4.5 bar. The other includes a pressure reducing valve pre-set at 3.0 bar, an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection, and a pressure relief valve pre-set at 4.5 bar. The product is also supplied with an expansion vessel and a tundish. The compression connection of each inlet control group is for use with the following pipes: Both for use with copper pipe (manufactured to BS EN 1057). The inlet control group without an adjustable pressure reducing valve can also be used with PB pipe (with inserts) (manufactured to BS EN 7291-2:2010) and PEX pipe (with inserts) (manufactured to BS EN 7291-3:2010). Maximum supply pressure to inlet control group pressure reducing valve: 16.0 bar. Maximum working pressure 4.0 bar. Maximum operating temperature 99°C. Cold supply only.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2312325
Size:
See model (capacity). 22mm compression (to inlet control group).
Marking:
Atlantic, address, pressure rating, serial number, capacity, and other technical information on adhesive label on body.
Installation Requirements:
R001 R140 R150 R360 R511
Expiry date:
31/12/2028
Model:
876509 - ATL CV4 STAINLESS STEEL FS 172L, 886123 - ATL CV4 STAINLESS STEEL FS 210L.
Product Images

Approval Holder:
Groupe Atlantic
Company Name
Groupe Atlantic
Address
Ideal Heating National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
01482 492251

View All Listings by this Company

Print This Approval


#240402709

Range of Indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 90˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check cartridge, verified by test (suitable for backflow protection against fluid category 2) an expansion vessel and tundish. Maximum working pressure: Secondary: 4.0 Bar Primary: 3.0 Maximum operating temperature 99.0°C

Section:
1890 Unvented Heating Apparatus
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Secondary: 22mm compression Primary: 22mm compression
Marking:
Gledhill logo, model name, capacity, max pressure, date of manufacture (D/MM/YYYY) and other technical information on label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
30/04/2029
Model:
Direct: SESINPDR090 SESINPDR120 SESINPDR150 SESINPDR170 SESINPDR200 SESINPDR250 SESINPDR300 Indirect: SESINPIN090 SESINPIN120 SESINPIN150 SESINPIN170 SESINPIN200 SESINPIN250 SESINPIN300

Approval Holder:
Gledhill Building Products Ltd
Company Name
Gledhill Building Products Ltd
Address
Sycamore Estate Blackpool
Postcode
FY4 3RL
Phone
(01253) 474439

View All Listings by this Company
Manufacturer:
Gledhill Building Products Ltd
Company Name
Gledhill Building Products Ltd
Address
Sycamore Estate Blackpool
Postcode
FY4 3RL
Phone
(01253) 474439

View All Listings by this Company

Print This Approval


#240604705

Range of primary hot water buffer tanks consisting of stainless steel shells. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.

Section:
1890 Unvented Heating Apparatus
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See models
Marking:
Adhesive label on body stating Lapesa (Manufacturer) Address, Model No, Year of manufacture, Capacity, Pressure rating, Serial number and other tech info.
Installation Requirements:
R001
Expiry date:
30/06/2029
Model:
MXM-RB-3000-PSS [3" male BSP inlet and outlet] MXM-RB-3000-PSS2 [2" male BSP inlet and outlet] MXM-RB-3000 [2" male BSP inlet and outlet] MXM-RB-2500-PSS [3" male BSP inlet and outlet] MXM-RB-2500-PSS2 [2" male BSP inlet and outlet] MXM-RB-2500 [2" male BSP inlet and outlet] MXM-RB-2000-PSS [3" male BSP inlet and outlet] MXM-RB-2000-PSS2 [2" male BSP inlet and outlet] MXM-RB-2000 [2" male BSP inlet and outlet] MXM-RB-1500-PSS [3" male BSP inlet and outlet] MXM-RB-1500-PSS2 [2" male BSP inlet and outlet] MXM-RB-1500 [2" male BSP inlet and outlet]

Approval Holder:
Mitsubishi Heavy Industries Air conditioning Europe
Company Name
Mitsubishi Heavy Industries Air conditioning Europe
Address
5 The Square Hayes Uxbridge Middlesex
Postcode
UB11 1ET
Country
United Kingdom
Phone
+44(0)75 8663 8352
General Email
mohamed.abdihakim.hp@mhi.com

View All Listings by this Company
Manufacturer:
Lapesa Grupo Empresarial S. L.
Company Name
Lapesa Grupo Empresarial S. L.
Address
Polígono Industrial Malpica, C/A, Parcela 1A, 50016 Zaragoza
Country
Spain
General Email

View All Listings by this Company

Print This Approval


#240604706

Range of primary hot water buffer tanks consisting of insulated enamel and Stainless steel shells. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.

Section:
1890 Unvented Heating Apparatus
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See models
Marking:
Adhesive label on body stating Lapesa (Manufacturer) Adress, Model No, serial No, Year of manufacture, Capacity, actual capacity max pressure and other tech info
Installation Requirements:
R001
Expiry date:
30/06/2029
Model:
CVM-RB-1000/PSS [3" male BSP inlet and outlet]. CVM-RB-1000/PSS2 [2" male BSP inlet and outlet]. CVM-RB-1000 [2" male BSP inlet and outlet]. CVM-RB-750/PSS [3" male BSP inlet and outlet]. CVM-RB-750/PSS2 [2" male BSP inlet and outlet]. CVM-RB-750 [2" male BSP inlet and outlet]. CVM-R-750/PSS [3" male BSP inlet and outlet]. CVM-R-750/PSS2 [2" male BSP inlet and outlet]. CVM-R-750 [2" male BSP inlet and outlet]. CVM-R-500/PSS [3" male BSP inlet and outlet]. CVM-R-500/PSS2 [2" male BSP inlet and outlet]. CVM-R-500 [2" male BSP inlet and outlet].

Approval Holder:
Mitsubishi Heavy Industries Air conditioning Europe
Company Name
Mitsubishi Heavy Industries Air conditioning Europe
Address
5 The Square Hayes Uxbridge Middlesex
Postcode
UB11 1ET
Country
United Kingdom
Phone
+44(0)75 8663 8352
General Email
mohamed.abdihakim.hp@mhi.com

View All Listings by this Company
Manufacturer:
Lapesa Grupo Empresarial S. L.
Company Name
Lapesa Grupo Empresarial S. L.
Address
Polígono Industrial Malpica, C/A, Parcela 1A, 50016 Zaragoza
Country
Spain
General Email

View All Listings by this Company

Print This Approval


#2103041

Ultraflow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103041
Size:
22mm compression (Inlet Manifold)
Marking:
Ultraflow on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2026
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
UD90 - ULTRAFLOW 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD120 - ULTRAFLOW 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UD150 – ULTRAFLOW 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD170 – ULTRAFLOW 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UD200 – ULTRAFLOW 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD250 – ULTRAFLOW 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD300 – ULTRAFLOW 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UI90-ULTRAFLOW 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI120 - ULTRAFLOW 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI150 - ULTRAFLOW 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI170 - ULTRAFLOW 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI200 - ULTRAFLOW 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI250 - ULTRAFLOW 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI300 - ULTRAFLOW 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UWD170 -ULTRAFLOW 170 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD200 -ULTRAFLOW 200 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD250 -ULTRAFLOW 250 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD300 -ULTRAFLOW 300 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWI170 ULTRAFLOW 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI200 ULTRAFLOW 200 NDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI250 ULTRAFLOW 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI300 ULTRAFLOW 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UDS60-ULTRAFLOW SLIM 60 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UDS90-ULTRAFLOW SLIM 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS120-ULTRAFLOW SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS150D-ULTRAFLOW SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS170D-ULTRAFLOW SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS200D-ULTRAFLOW SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UIS60-ULTRAFLOW SLIM 60 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS90-ULTRAFLOW SLIM 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS120-ULTRAFLOW SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS150-ULTRAFLOW SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS170-ULTRAFLOW SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS200-ULTRAFLOW SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER

Approval Holder:
L & M (HEATING) SUPPLIES LTD.
Company Name
L & M (HEATING) SUPPLIES LTD.
Address
103 LOCKFIELD AVENUE ENFIELD, ENFIELD, MIDDLESEX
Postcode
EN3 7PY

View All Listings by this Company

Print This Approval


#2201107

Range of Ultraflow Air bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added January 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
1890 Unvented Heating Apparatus
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression. Return circuit: 22mm compression.
Marking:
Ultraflow Air on label on front of body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/01/2027
Model:
UOD120 – ULTRAFLOW AIR 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UOD150 – ULTRAFLOW AIR 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOD170 – ULTRAFLOW AIR 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UOD200 – ULTRAFLOW AIR 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOD250 – ULTRAFLOWAIR 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOD300 – ULTRAFLOW AIR 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI120 – ULTRAFLOW AIR 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI150 – ULTRAFLOW AIR 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI170 – ULTRAFLOW AIR 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI200 – ULTRAFLOW AIR 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI250 – ULTRAFLOW AIR 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI300 - ULTRAFLOW AIR 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS120-ULTRAFLOW AIR SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS150-ULTRAFLOW AIR SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS170-ULTRAFLOW AIR SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS200-ULTRAFLOW AIR SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UOIS120-ULTRAFLOW AIR SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOIS150-ULTRAFLOW AIR SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOIS170-ULTRAFLOW AIR SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOIS200-ULTRAFLOW AIR SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER

Approval Holder:
L & M (HEATING) SUPPLIES LTD.
Company Name
L & M (HEATING) SUPPLIES LTD.
Address
103 LOCKFIELD AVENUE ENFIELD, ENFIELD, MIDDLESEX
Postcode
EN3 7PY

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 3

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.