Kingfisher International Products Ltd. Approvals


#1904370

Range of single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headwork and single lever operating members. The product has a pull-out spray outlet which incorporates a plastic aerator and a self-closing trigger mechanism. Maximum working pressure 10 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1904370
Expiry date:
30/04/2024
Size:
Stainless steel braided PEX lined hose assembly incorporating ½” captive nut end connections.
Marking:
Gaoao on body
Installation Requirements:
R001 R006 R009 R010
Model:
3663602799849 COMBINATION TAP ASSEMBLIES – PULL OUT SPRAY
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company
Manufacturer:
Zhejiang Gaoao Sanitary Ware Co. Ltd.
Company Name
Zhejiang Gaoao Sanitary Ware Co. Ltd.
Address
No.22 Yongda Road, Jiangkou Street, Huangyan District, Taizhou City Zhejiang Province

View All Listings by this Company

Print This Approval


#1906398

Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator and pull down spray. The inlet hoses incorporate a combined washer and stainless steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1906398
Expiry date:
30/06/2024
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating 1/2” captive nut end connections
Marking:
Cooke & Lewis on tap body
Installation Requirements:
R001 R006 R009 R010
Model:
3663602792123 COMBINATION TAP ASSEMBLIES
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval


#1909119

Range of quarter turn ceramic disc headworks with brass bodies, NBR ‘O’-rings and plastic washers. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.

Section:
0440 Headworks
WRAS Approval Number:
1909119
Expiry date:
30/09/2024
Size:
½” BSP (M)
Marking:
PLUMBSURE, WRAS & DATE OF MANUFACTURE DD/MM/YY ON BODY
Installation Requirements:
R001
Model:
5052931415496-C, 5052931415496-H, 5052931415526-C & 5052931415526-H 1/4 TURN CERAMIC DISC HEADWORKS
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval


#1909120

Range of quarter turn ceramic disc headworks with brass bodies, NBR ‘O’-rings and plastic washers. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.

Section:
0440 Headworks
WRAS Approval Number:
1909120
Expiry date:
30/09/2024
Size:
½” BSP (M)
Marking:
FLOMASTA, WRAS & DATE OF MANUFACTURE DD/MM/YY ON BODY
Installation Requirements:
R001
Model:
2611F-C, 2611F-H, 1908F-C, 1908F-H, 2961F-C & 2961F-H 1/4 TURN CERAMIC DISC HEADWORKS
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval


#2001132

Range of non-rising spindle headworks with brass bodies and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0440 Headworks
WRAS Approval Number:
2001132
Expiry date:
31/01/2025
Size:
½” BSP (M)
Marking:
FLOMASTA, WRAS and date of manufacture (DD/MM/YY) on body.
Installation Requirements:
R001
Model:
3279F & 7960F non-rising spindle headworks
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval


#2001133

Range of non-rising spindle headworks with brass bodies and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0440 Headworks
WRAS Approval Number:
2001133
Expiry date:
31/01/2025
Size:
½” BSP (M)
Marking:
PLUMBSURE, WRAS and date of manufacture (DD/MM/YY) on body.
Installation Requirements:
R001
Model:
5052931415502 & 5052931415533 non-rising spindle headworks
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval


#2006076

Range of single hole, single outlet (swivel) combination tap assemblies incorporating a brass body (chrome, nickel or black finish) and ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2006076
Expiry date:
30/06/2025
Marking:
COOKE & LEWIS (BRAND OF KINGFISHER) & DATE OF MANUFACTURE MM/YYYY ON OPERATING MEMBER
Installation Requirements:
R001 R006 R009 R010
Model:
3663602482123 ARUVI SINGLE LEVER KITCHEN TAP, 3663602482208 GULLFOSS FOLDING KITCHEN MIXER TAP CHROME, 3663602482161 ARYA SINGLE LEVER KITCHEN TAP CHROME, 3663602482178 ARYA SINGLE LEVER KITCHEN TAP B.NICKEL 3663602482130 FARIN SPRING NECK KITCHEN TAP CHROME, 3663602482154 FARIN SPRING NECK KITCHEN TAP CHROME BK 3663602482147 FARIN SPRING NECK KITCHEN TAP B NICKEL
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval


#2006079

Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C

Section:
1210 Fittings for use with Tube and Pipe
Section Subtitle:
End feed, for use with copper tube. Unless specified in the individual approval, the products within this section are not suitable for below ground use
WRAS Approval Number:
2006079
Expiry date:
30/06/2025
Size:
6mm – 54mm.
Marking:
FLOMASTA (BRAND OF KINGFISHER) & size on body.
Installation Requirements:
R001
Model:
5001, 5002, 5040, 5041, 5090, 5092, 5085, 5086, 5270, 5301, 5240, 5243, 5130, 5130R, 5060, 5062, 5063, 5064, 5065 & 5270S, L5090.
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval


#2006078

Range of copper solder ring fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1115 Fittings for use with Tube and Pipe
Section Subtitle:
Capillary, solder ring, lead free. Unless specified in the individual approval, the products within this section are not suitable for below ground use
WRAS Approval Number:
2006078
Expiry date:
30/06/2025
Size:
8mm – 54mm 3/8” – 2”
Marking:
FLOMASTA (BRAND OF KINGFISHER) & SIZE ON BODY
Installation Requirements:
R001
Model:
SR5270, SR5090, SR5092, SR5301,SR5240, SR5243, SR5040, SR5041, SR5130, SR5130R, SR5062, SR5063, SR5271, SR5085, SR5086, SR5270S. All fittings are for use with copper pipe to EN 1057.
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval


#1910359

Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass or brushed gold PVD). Incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a rubber flow straightener. Maximum working pressure 5 bar. Maximum operating temperature 70°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1910359
Expiry date:
31/10/2024
Size:
Nylon braided PEX lined hose assembly incorporating ½” captive nut end connections.
Marking:
Kingfisher good home logo and date of manufacture mm/yyyy on body
Installation Requirements:
R001 R006 R009 R010
Model:
3663602481829 Filbert Side Lever (Chrome) & 3663602481843 Filbert Side Lever (Brass) COMBINATION TAP ASSEMBLIES
Factor:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 PaddingtonSquare, London
Postcode
W2 6PX

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 9

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.