Ideal Standard (UK) Ltd Approvals


#1901006

Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1901006
Expiry date:
31/07/2024
Size:
Stainless steel braided EPDM lined flexible hose assemblies with 15mm compression end connections.
Marking:
Ideal Standard on operating member.
Installation Requirements:
R001 R006 R010
Model:
B2136AA Calista.
Manufacturer:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1907004

Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
0470 Combination Tap Assemblies
Section Subtitle:
Single hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of:- • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1907004
Expiry date:
31/07/2024
Size:
Stainless steel braided polyethylene lined flexible hoses incorporating 3/8” BSP captive nut end connections, with optional 15mm compression fittings
Marking:
Ideal Standard on operating member
Installation Requirements:
R001 R006 R009 R010
Model:
B0744AA Tempo
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1907027

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic cartridge headworks with dome type operating member. The spout outlet incorporates a plastic aerator. The product is supplied with an optional plastic flow straightener & pop up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1907027
Expiry date:
31/07/2024
Size:
Stainless steel braided EPDM lined hose assembly incorporating 15mm compression end connections
Marking:
Ideal Standard Logo on operating member
Installation Requirements:
R001 R006 R010
Model:
B9673AA Alto Dual Control Basin Mixer
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1907031

Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with dome type operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic aerator. Incorporates approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C

Section:
0520 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, fixed, manually operated diverter to shower outlet.
WRAS Approval Number:
1907031
Expiry date:
31/07/2024
Size:
3/4" BSP Male
Marking:
Ideal standard logo on operating member
Installation Requirements:
R001 R005 R020
Model:
A4815AA Ceratherm 100 thermostatic exposed bath shower mixer, 2 hole
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company
Manufacturer:
Ideal Standard Produktions - GmbH
Company Name
Ideal Standard Produktions - GmbH
Address
EUSKIRCHENER STRASSE 80 53121 BONN GERMANY

View All Listings by this Company

Print This Approval


#1909001

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1909001
Expiry date:
30/09/2024
Size:
Stainless steel braided polyethylene lined flexible hose assemblies with ⅜” captive nut end connections and ⅜” BSP (M) x 15mm compression adaptors.
Marking:
Ideal standard logo on top of operating member.
Installation Requirements:
R001 R006 R009 R010
Model:
B2326AA – CERAFLEX BSN MXR GRANDE R-MTD CHR, NO PUW Model added May 2021: B1714AA - CERAFLEX ONE-HOLE BASIN MIXER GRANDE
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1909002

Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass finish) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic flow straightener or optional plastic aerator. Some products are supplied with a pop-up or click type waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1909002
Expiry date:
30/09/2024
Size:
Stainless steel braided polyethylene lined flexible hose assemblies with ⅜” captive nut end connections and ⅜” BSP (M) x 15mm compression adaptors.
Marking:
Ideal Standard on operating member.
Installation Requirements:
R001 R006 R009 R010
Model:
BC334AA- ESINO SL Basin mixer chrome with CLICK waste, BC335AA- ESINO SL Basin mixer GRANDE chrome with CLICK waste, BC322AA- Dot 2.0 SL Basin mixer chrome with CLICK waste, BC680AA Alpha Basin Mixer with PUW, BC678AA Alpha Basin H75 Mixer no PUW, BC679AA Alpha Basin H75 Mixer no PUW.
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1909069

Combined bath filler and overflow waste assembly incorporating a manual operated pop-up waste using a dome type operating member. The inlet incorporates an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate It provides backflow protection. Maximum operating temperature 60°C.

Section:
1535 Miscellaneous
Section Subtitle:
Tap accessories.
WRAS Approval Number:
1909069
Expiry date:
30/09/2024
Note:
Open outlet use only
Size:
½” BSP (M)
Marking:
ISI on waste
Installation Requirements:
R001 R090 R160
Model:
E1485AA LUXURY BATH FILLER, CLICKER WASTE AND OVERFLOW E1484AA LUXURY BATH CLICKER WASTE AND OVERFLOW
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1910047

Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C

Section:
0510 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, fixed.
WRAS Approval Number:
1910047
Expiry date:
31/10/2024
Size:
¾” BSP (M)
Marking:
Ideal Standard on operating member
Installation Requirements:
R001 R005 R010
Model:
BC327AA – DOT 2.0 2 HOLE DUAL CONTROL BATH FILLER
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1912021

Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Model B1146AA has a flow regulator in the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
1800 Taps
Section Subtitle:
Pillar, metal.
WRAS Approval Number:
1912021
Expiry date:
31/12/2024
Size:
½” or ¾” BSP Male
Marking:
Ideal standard on operating member
Installation Requirements:
R001 R005
Model:
B1146AA Calista & B1147AA Calista
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1909404

Range of shower outlets with chrome plated brass front plates incorporating a stainless steel filter at the inlet. Maximum operating temperature 85°C.

Section:
1650 Shower Outlets
WRAS Approval Number:
1909404
Expiry date:
30/09/2024
Note:
Open outlet use only
Size:
½” BSP (F)
Marking:
IDEAL STANDARD ON SHOWER HEAD
Installation Requirements:
R001 R040
Model:
B0024AA IDEALRAIN CUBE M1 RAINSHOWER
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#2001016

Single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. The BC574AA model is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2001016
Expiry date:
31/01/2025
Note:
No testing performed on pop-up waste.
Size:
Stainless steel braided polyethylene lined flexible hose assemblies with ⅜” captive nut end connections.
Marking:
Ideal standard logo on operating member
Installation Requirements:
R001 R006 R009 R010
Model:
BC573AA - TEMPO BASIN MIXER CHROME NO PUW BC574AA - TEMPO BASIN MIXER CHROME PUW
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#2001049

Range of basin pillar taps (chromium plated brass) with quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1800 Taps
Section Subtitle:
Pillar, metal.
WRAS Approval Number:
2001049
Expiry date:
31/01/2025
Size:
½” BSP (M)
Marking:
Ideal Standard logo on operating member
Installation Requirements:
R001 R006
Model:
B0162AA - Cube G1/2” Basin Pillar Taps. B8074AA - Active G1/2” Basin Pillar Taps.
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#2001050

Range of bath pillar taps (chromium plated brass) with quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1800 Taps
Section Subtitle:
Pillar, metal.
WRAS Approval Number:
2001050
Expiry date:
31/01/2025
Size:
¾” BSP (M)
Marking:
Ideal Standard Logo on Operating Member.
Installation Requirements:
R001 R005
Model:
B0163AA - Cube G3/4” Bath Pillar Taps. B8076AA - Active G3/4” Bath Pillar Taps.
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#2003701

Shower outlet with chromium plated brass body, incorporating a stainless-steel mesh strainer in the shower head connector. Maximum operating temperature 85°C.

Section:
1650 Shower Outlets
WRAS Approval Number:
2003701
Expiry date:
31/03/2025
Note:
Open Outlet only
Size:
½” BSP (M)
Marking:
Ideal standard logo on face of shower head.
Installation Requirements:
R001 R040
Model:
B9436AA – Idealrain S1 Rainshower Fixed Shower Head
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#2001019

Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quater turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0510 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, fixed.
WRAS Approval Number:
2001019
Expiry date:
31/01/2025
Size:
¾” BSP (M)
Marking:
Ideal Standard Logo on operating members
Installation Requirements:
R001 R005 R010
Model:
B9674AA Alto dual control two hole bath filler. B1151AA Calista DC 2H Bath Filler.
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#2003009

Range of plastic bodied ceramic cartridge headworks with EPDM ‘O’-rings, to be installed in specifically dimensioned bodies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C

Section:
0440 Headworks
WRAS Approval Number:
2003009
Expiry date:
31/03/2025
Size:
ØD 28MM
Marking:
Ideal Standard on red ring
Installation Requirements:
R001
Model:
CARTRIDGE IS28 SD METAL PIVOT (A956307) CARTRIDGE IS28 SD PLASTIC PIVOT (A956308) CARTRIDGE IS28 SD PLASTIC PIVOT CLICK (A956309) CARTRIDGE IS28 SD SHORT PLASTIC PIVOT (A956310)
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#2003022

Ceramic cartridge headwork with a plastic body, incorporating EPDM seals. The product is intended for insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC

Section:
0440 Headworks
WRAS Approval Number:
2003022
Expiry date:
31/03/2025
Size:
Ø38mm
Marking:
Ideal Standard on temperature limiting ring
Installation Requirements:
R001
Model:
A956131 Cartridge 38 SD Dry Application
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#2003066

Pillar tap (chromium plated brass) incorporating a quarter turn ceramic disc headwork and cube type operating member. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
1800 Taps
Section Subtitle:
Pillar, metal.
WRAS Approval Number:
2003066
Expiry date:
31/03/2025
Size:
½” BSP (M)
Marking:
‘ISI’ on rear of tap body.
Installation Requirements:
R001 R006
Model:
B0728AA
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1910066

Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C

Section:
0510 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, fixed.
WRAS Approval Number:
1910066
Expiry date:
31/10/2024
Size:
¾” BSP (M)
Marking:
Ideal Standard Logo on operating member
Installation Requirements:
R001 R005 R010
Model:
BC658AA ALPHA 2 HOLE DUAL CONTROL BATH FILLER COMBINATION TAP ASSEMBLY
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#2004058

Two-hole, singe outlet (fixed) combination tap assembly (chromium plated brass). Incorporating ¼ turn ceramic disc headworks with single lever type operating members. The outlet incorporates a plastic flow straightener. Product is also supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.

Section:
0510 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, fixed.
WRAS Approval Number:
2004058
Expiry date:
30/04/2025
Size:
¾” BSP (M)
Marking:
Ideal Standard logo on operating member.
Installation Requirements:
R001 R005 R010
Model:
B0293AA – Opus dual control bath filler
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 3

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.