Altecnic Limited Approvals


#2304336

A range of in-line, lever operated spherical isolation valves with chrome plated brass bodies & chrome plated balls, stainless steel wire filters and plastic flow regulators. Compression connections to be used with copper pipe EN1057 only. Maximum working pressure 10.0 bar.

Non-metallic materials and components comply with BS6920 at 60°C except for models AI-811215 & AI-81121518 CST with temperatures of 85°C

Section:
2260 Valves
Section Subtitle:
Spherical, metal.
WRAS Approval Number:
2304336
Note:
Claims of flow rate performance have not been verified and are not covered by this approval.
Size:
15mm x 15mm compression
Marking:
Airaga logo and flow arrow cast on body.
Installation Requirements:
R001 R120
Expiry date:
30/04/2028
Model:
AI-81121504 - 15mm x 15mm valve c/w 4 litre flow regulator, AI-81121506 - 15mm x 15mm valve c/w 6 litre flow regulator, AI-81121508 - 15mm x 15mm valve c/w 8 litre flow regulator, AI-81121510 - 15mm x 15mm valve c/w 10 litre flow regulator, AI-81121512 - 15mm x 15mm valve c/w 12 litre flow regulator, AI-81121515 - 15mm x 15mm valve c/w 15 litre flow regulator, AI-81121518 - 15mm x 15mm valve c/w 18 litre flow regulator, AI-811215 - 15mm x 15mm valve, A-125-2001 CST - 15mm x 15mm valve.
Product Images

Approval Holder:
Altecnic Limited
Company Name
Altecnic Limited
Address
Francesco House, Staples Close Stafford Staffordshire
Postcode
ST16 1WQ
Phone
+44 (0)1785 218200
General Email
sales@altecnic.co.uk

View All Listings by this Company
Manufacturer:
Airaga Rubinetterie Spa
Company Name
Airaga Rubinetterie Spa
Address
Via Per Briga 42 28024 Gozzano Novara
General Email

View All Listings by this Company

Print This Approval


#2304084

Electrolytic and magnetic scale inhibitors incorporating copper or nickel coated copper bodies. Compression models are to be used with copper pipe manufactured to BS EN1057. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2410 Water conditioners, de-scalers, phosphate dosing, magnetic, electrolytic and electronic
WRAS Approval Number:
2304084
Note:
R008 applies to the push-fit fitting on model LG07 which is to be installed where light is excluded.
Marking:
Altecnic Dirtmag IQ, WRAS, size and contact details on adhesive label on body.
Installation Requirements:
R001 R008 R120 R170
Expiry date:
30/04/2028
Model:
Altecnic DIRTMAG iQ (Part Code 114-9003) ELECTROLYTIC 15mm to 15mm compression. Altecnic DIRTMAG iQ (Part Code 114-9007) MAGNETIC SCALE INHIBITORS 15mm to 15mm push-fit.

Approval Holder:
Altecnic Limited
Company Name
Altecnic Limited
Address
Francesco House, Staples Close Stafford Staffordshire
Postcode
ST16 1WQ
Phone
+44 (0)1785 218200
General Email
sales@altecnic.co.uk

View All Listings by this Company

Print This Approval


#2307350

Range of drain taps with a brass body and rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1770 Taps
Section Subtitle:
Draining, for above ground use only.
WRAS Approval Number:
2307350
Size:
SEE MODEL.
Marking:
Altecnic logo and date of manufacture (XX) on body.
Installation Requirements:
R001 R511
Expiry date:
31/07/2028
Model:
BI-WM0004: 15mm push fit extended tail, Type A. BI-WM0005: 15mm plain tail, Type A. BI-WM0006: ½” BSP (M), Type A. BI-WM0007: ¾” BSP (M), Type A.
Product Images

Approval Holder:
Altecnic Limited
Company Name
Altecnic Limited
Address
Francesco House, Staples Close Stafford Staffordshire
Postcode
ST16 1WQ
Phone
+44 (0)1785 218200
General Email
sales@altecnic.co.uk

View All Listings by this Company

Print This Approval


#2402800

Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Models ALT-ST0019 & ALT-ST0019 are supplied with a pressure gauge. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1015 Filling Loop
Size:
15mm compression or 15mm pushfit.
Marking:
Altecnic logo, flow arrow and CR on valve. Altecnic, WRAS and date of manufacture (YYYY) on hose.
Installation Requirements:
R001
Expiry date:
28/02/2029
Model:
CA-300606, CA-100990, TP-109-9000, TP-109-9001, JI-MORFLP, ER-ECOLOOP, BG-LOOP, CA-300611, JI-300608, AI-300605, K-109-3001, ALT-ST0035, ALT-ST0019.

Approval Holder:
Altecnic Limited
Company Name
Altecnic Limited
Address
Francesco House, Staples Close Stafford Staffordshire
Postcode
ST16 1WQ
Phone
+44 (0)1785 218200
General Email
sales@altecnic.co.uk

View All Listings by this Company

Print This Approval


#2402801

Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1015 Filling Loop
Size:
15mm compression or 15mm pushfit.
Marking:
Altecnic logo, flow arrow and CR on valve. Altecnic, WRAS and date of manufacture (YYYY) on hose.
Installation Requirements:
R001
Expiry date:
28/02/2029
Model:
PLUMBRIGHT FILLING LOOP - 689142.

Approval Holder:
The Highbourne Group, City Plumbing Supplies
Company Name
The Highbourne Group, City Plumbing Supplies
Address
Branch Support Centre Highbourne House Highbourne House Crick Northampton
Postcode
NN6 7SL
Phone
07342 078865
General Email
Lindsey.cocks-stevens@cityplumbing.co.uk

View All Listings by this Company
Manufacturer:
Altecnic Limited
Company Name
Altecnic Limited
Address
Francesco House, Staples Close Stafford Staffordshire
Postcode
ST16 1WQ
Phone
+44 (0)1785 218200
General Email
sales@altecnic.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 7 of 11

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.