Unvented Heating Apparatus

Section Code 1890 :

Back To Directory Sections

#1904032

Range of hot water buffer tanks consisting of insulated stainless steel shells. Maximum working pressure 8.0 bar. Maximum operating temperature 90°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1904032
Expiry date:
30/04/2024
Size:
1500-3000 litre
Marking:
“Lapesa”, model number & technical information on adhesive label.
Installation Requirements:
R001 R511
Model:
MASTER INOX Range: MXM-RB-3000-PSS [3" male BSP inlet and outlet], MXM-RB-3000-PSS2 [2" male BSP inlet and outlet], MXM-RB-3000 [2" male BSP inlet and outlet], MXM-RB-2500-PSS [3" male BSP inlet and outlet], MXM-RB-2500-PSS2 [2" male BSP inlet and outlet], MXM-RB-2500 [2" male BSP inlet and outlet], MXM-RB-2000-PSS [3" male BSP inlet and outlet], MXM-RB-2000-PSS2 [2" male BSP inlet and outlet], MXM-RB-2000 [2" male BSP inlet and outlet], MXM-RB-1500-PSS [3" male BSP inlet and outlet], MXM-RB-1500-PSS2 [2" male BSP inlet and outlet] & MXM-RB-1500 [2" male BSP inlet and outlet].
Factor:
Mitsubishi Heavy Industries Ltd
Company Name
Mitsubishi Heavy Industries Ltd
Address
3-1 Asahi Nishibiwajima-Cho Kiyosu
Country
Aichi

View All Listings by this Company
Manufacturer:
Lapesa
Company Name
Lapesa
Address
Poligono Industrial de Malpica Calle A Percel 1-B
Country
50057 Zaragoza
Phone
+34 976 465 180

View All Listings by this Company

Print This Approval


#1904351

Range of free standing unvented vitreous enamel lined carbon steel buffer vessels. The vessels are supplied with a sacrificial magnesium anode. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1904351
Expiry date:
31/12/2024
Size:
See model
Marking:
Andrews Water heaters (brand of Baxi), manufacturer’s address, model, serial no., year of manufacture (YYYY), max. pressure, capacity and other technical information on adhesive label on body. on body
Installation Requirements:
R001 R140
Model:
Buffer GL300-10 – inlet 1” BSP (M). Buffer GL500-10 – inlet 1” BSP (M). Buffer GL800-10 – inlet 1¼” BSP (M).
Factor:
Baxi Heating UK Ltd.
Company Name
Baxi Heating UK Ltd.
Address
Club Street Bamber Bridge Preston Lancaster
Postcode
PR5 6FN

View All Listings by this Company

Print This Approval


#1904352

Range of free standing unvented vitreous enamel lined carbon steel buffer vessels. The vessels are supplied with a sacrificial magnesium anode. Maximum working pressure 8.0 bar. Maximum operating temperature 90°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1904352
Expiry date:
30/04/2024
Size:
See model
Marking:
Andrews Water heaters (brand of Baxi), manufacturer’s address, model, serial no., year of manufacture (YYYY), max. pressure, capacity and other technical information on adhesive label on body. on body
Installation Requirements:
R001 R140
Model:
Buffer GL200-8 – inlet 1” BSP (M). Buffer GL300-8 – inlet 1” BSP (M). Buffer GL500-8 – inlet 1” BSP (M). Buffer GL800-8 – Inlet 1” BSP (M). Buffer GL1000-8 – Inlet 1” BSP (M).
Factor:
Baxi Heating UK Ltd.
Company Name
Baxi Heating UK Ltd.
Address
Club Street Bamber Bridge Preston Lancaster
Postcode
PR5 6FN

View All Listings by this Company

Print This Approval


#1905073

Mixergy MX range of stainless steel direct and indirect, single and dual coil, hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C and a safety kit (manifold) consisting of a check valve, strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and an expansion vessel is also supplied. Maximum working pressure secondary circuit 5.5 bar Maximum operating pressure primary coils 3.5 bar Maximum operating temperature 70˚C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1905073
Expiry date:
31/05/2024
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre.
Marking:
Mixergy and technical information (including pressure) on adhesive label on body.
Installation Requirements:
R001 R140 R360
Model:
Mixergy MX xxx ELE-EXT w-w-x-y-zz Direct, Unvented, External Expansion, Hot Water Storage Cylinders, 90-300 Litre capacity. Mixergy MX xxx IDE EXT w-w-x-y-zz Indirect Unvented, External Expansion,Hot Water Storage Cylinders, 150-300 Litre capacity. Mixergy MX xxx Duo EXT w-w-x-y-zz Indirect Dual Coil, Unvented, External Expansion, Hot Water Storage Cylinders,210-300 Litre capacity. Where: xxx=Tank capacity (litres): 90,120,150,180,210,250,300 EXT= defines the expansion vessel as external to the cylinder. W=Diameter 475,550,690 W= Main immersion 1- Single element - 2 dual element (for PV diverter use). X = lower immersion: 0- not fitted, 1 with back up immersion. Y = Controller: A – Industrial (DIN rail), B – Domestic (PCB). Only affects type of external electronic controller used. zz= Options: 00 – none, 01 – PV diverter switch. Only affects electronic controller options.
Factor:
Mixergy Ltd.
Company Name
Mixergy Ltd.
Address
2 Canal View Wharf Farm Eynsham
Postcode
OX29 4DB
Country
Oxfordshire

View All Listings by this Company
Manufacturer:
RM Cylinders
Company Name
RM Cylinders
Address
4 Valencia Park, Gilcar Way, Wakefield Europort
Postcode
WF10 5QS
Country
West Yorkshire

View All Listings by this Company

Print This Approval


#1906091

Range of hot water buffer tanks consisting of insulated enamel vitrified carbon steel shells. Maximum working pressure 8.0 bar. Maximum operating temperature 90°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1906091
Expiry date:
30/06/2024
Size:
500-1000 litre
Marking:
‘Lapesa’ & model on adhesive label.
Installation Requirements:
R001 R511
Model:
CORAL VITRO Range: CVM-RB-1000/PSS [3" male BSP inlet and outlet]. CVM-RB-1000/PSS2 [2" male BSP inlet and outlet]. CVM-RB-1000 [2" male BSP inlet and outlet]. CVM-RB-750/PSS [3" male BSP inlet and outlet]. CVM-RB-750/PSS2 [2" male BSP inlet and outlet]. CVM-RB-750 [2" male BSP inlet and outlet]. CVM-R-750/PSS [3" male BSP inlet and outlet]. CVM-R-750/PSS2 [2" male BSP inlet and outlet]. CVM-R-750 [2" male BSP inlet and outlet]. CVM-R-500/PSS [3" male BSP inlet and outlet]. CVM-R-500/PSS2 [2" male BSP inlet and outlet]. CVM-R-500 [2" male BSP inlet and outlet].
Factor:
Mitsubishi Heavy Industries Air-conditioning Europe Limited
Company Name
Mitsubishi Heavy Industries Air-conditioning Europe Limited
Address

View All Listings by this Company
Manufacturer:
Lapesa Grupo Empresarial S. L.
Company Name
Lapesa Grupo Empresarial S. L.
Address

View All Listings by this Company

Print This Approval


#1907057

Solar twin coil range of stainless steel indirect hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a check valve, strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish, expansion vessel and a drain valve also comes supplied. Maximum operating pressure secondary circuit 5.5 bar. Maximum operating pressure primary circuit 3.0 bar. Maximum operating pressure solar circuit 5.5 bar. Maximum operating temperature 65˚C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1907057
Expiry date:
31/07/2024
Size:
25 litre, 90 litre, 150 litre, 170 litre, 200 litre, 250 litre, 300 litre
Marking:
Telford, model, pressure, capacity and technical info on adhesive label on body
Installation Requirements:
R001 R140 R530 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20OC and 45 OC. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
ornado Direct 3.0 90 litre Tornado Direct 3.0 125 litre Tornado Direct 3.0 150 litre Tornado Direct 3.0 170 litre Tornado Direct 3.0 200 litre Tornado Direct 3.0 250 litre Tornado Direct 3.0 300 litre Tornado Indirect 3.0 90 litre Tornado Indirect 3.0 90 litre Tornado Indirect 3.0 125 litre Tornado Indirect 3.0 150 litre Tornado Indirect 3.0 170 litre Tornado Indirect 3.0 200 litre Tornado Indirect 3.0 250 litre Tornado Indirect 3.0 300 litre Tornado twin coil 3.0 170 litre Tornado twin coil 3.0 200 litre Tornado twin coil 3.0 250 litre Tornado twin coil 3.0 300 litre
Factor:
Telford Copper and Stainless Ltd.
Company Name
Telford Copper and Stainless Ltd.
Address
Furrows Business Park Haybridge Road Wellington
Postcode
TF1 2DF
Country
Telford

View All Listings by this Company
Manufacturer:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF
Country
Wellington

View All Listings by this Company

Print This Approval


#1909074

Mitsubishi EHPT20X-MHEDW indirectly heated stainless-steel storage cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. The product is supplied with a safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, a pressure relief valve set at 6.0 bar and a pressure reducing valve set at 3.5 bar. The product is also supplied with a tundish, an expansion vessel and a filling loop assembly, consisting of a stainless steel braided EPDM lined flexible hose, a lever operated brass spherical valve and a DZR brass double check valve assembly (suitable for backflow protection against Fluid Category 3) that incorporates a lever operated spherical valve. Maximum working pressure secondary circuit 5.5 bar. Maximum working pressure primary circuit 2.5 bar. Maximum operating temperature 70°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909074
Expiry date:
30/09/2024
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
200 Litre – 22m compression
Marking:
Mitsubishi, model, technical info including pressures and capacity on adhesive label on top of unit.
Installation Requirements:
R001 R140 R360
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
EHPT20X-MHEDW
Manufacturer:
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Address
Nettlehill Road, Houston Industrial Estate, Livingston
Postcode
EH54 5EQ
Country
United Kingdom
Phone
01405 44 55 00

View All Listings by this Company

Print This Approval


#1909091

STELFLOW range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909091
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre, 350 litre, 400 litre, 450 litre, 500 litre.
Marking:
Stelflow and RM Cylinders on cylinder. RM Cylinders and technical information including pressures and capacity on adhesive label on cylinder.
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TRSMVD-0090LFC -RM STELFLOW 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0120LFB -RM STELFLOW 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0150LFB -RM STELFLOW 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0180LFB -RM STELFLOW 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0210LFC -RM STELFLOW 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0250LFC -RM STELFLOW 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0300LFC -RM STELFLOW 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0350LFC -RM STELFLOW 350 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0400LFC -RM STELFLOW 400 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0450LFC -RM STELFLOW 450 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0500LFC -RM STELFLOW 500 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0090LFC -RM STELFLOW 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0120LFB -RM STELFLOW 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0150LFB -RM STELFLOW 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0180LFB -RM STELFLOW 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0210LFC -RM STELFLOW 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0250LFC -RM STELFLOW 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0300LFC -RM STELFLOW 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0350LFC -RM STELFLOW 350 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0400LFC -RM STELFLOW 400 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0450LFC -RM STELFLOW 450 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0500LFC -RM STELFLOW 500 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER TRSMVE-0150LFB -RM STELFLOW 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0180LFB -RM STELFLOW 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0210LFC -RM STELFLOW 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0250LFC -RM STELFLOW 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0300LFC -RM STELFLOW 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0350LFC -RM STELFLOW 350 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0400LFC -RM STELFLOW 400 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0450LFC -RM STELFLOW 450 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0500LFC -RM STELFLOW 500 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0150LFB -RM STELFLOW 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0150LFB -RM STELFLOW 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0210LFC -RM STELFLOW 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0250LFC -RM STELFLOW 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0300LFC -RMSTELFLOW 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0350LFC -RM STELFLOW 350 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0400LFC -RM STELFLOW 400 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0450LFC -RM STELFLOW 450 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0500LFC -RM STELFLOW 500 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER
Manufacturer:
RM Cylinders
Company Name
RM Cylinders
Address
4 Valencia Park, Gilcar Way, Wakefield Europort
Postcode
WF10 5QS
Country
West Yorkshire

View All Listings by this Company

Print This Approval


#1909103

THERMAQ PROLITE range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909103
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre,
Marking:
PROLITE SS ON CYLINDER THERMAQ PROLITE, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TTPMVD-0090LFC THERMAQ PROLITE SS 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0120LFB THERMAQ PROLITE SS 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0150LFB THERMAQ PROLITE SS 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0180LFB THERMAQ PROLITE SS 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0210LFC THERMAQ PROLITE SS 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0250LFC THERMAQ PROLITE SS 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0300LFC THERMAQ PROLITE SS 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0090LFC THERMAQ PROLITE SS 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0120LFB THERMAQ PROLITE SS 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0150LFB THERMAQ PROLITE SS 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0180LFB THERMAQ PROLITE SS 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0210LFC THERMAQ PROLITE SS 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0250LFC THERMAQ PROLITE SS 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0300LFC THERMAQ PROLITE SS 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER.
Factor:
Thermaq Ltd
Company Name
Thermaq Ltd
Address
Sandbeds Trading Estate Dewsbury Road Ossett
Postcode
WF5 9ND
Country
West Yorkshire
General Email
steve.woollas@rmcylinders.com

View All Listings by this Company

Print This Approval


#1909104

THERMAQ EVOCYL range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909104
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre, 350 litre, 400 litre, 450 litre, 500 litre.
Marking:
THERMAQ EVOCYL ON CYLINDER THERMAQ EVOCYL, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TTEMVD-0090LFC -THERMAQ EVOCYL 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0120LFB -THERMAQ EVOCYL 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0150LFB -THERMAQ EVOCYL 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER TTEMVD-0180LFB -THERMAQ EVOCYL 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0210LFC -THERMAQ EVOCYL 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0250LFC -THERMAQ EVOCYL 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0300LFC -THERMAQ EVOCYL 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0350LFC -THERMAQ EVOCYL 350 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0400LFC -THERMAQ EVOCYL 400 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0450LFC -THERMAQ EVOCYL 450 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0500LFC -THERMAQ EVOCYL 500 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0090LFC -THERMAQ EVOCYL 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0120LFB -THERMAQ EVOCYL 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0150LFB -THERMAQ EVOCYL 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0180LFB -THERMAQ EVOCYL 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0210LFC -THERMAQ EVOCYL 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0250LFC -THERMAQ EVOCYL 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0300LFC -THERMAQ EVOCYL 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0350LFC -THERMAQ EVOCYL 350 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0400LFC -THERMAQ EVOCYL 400 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0450LFC -THERMAQ EVOCYL 450 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0500LFC -THERMAQ EVOCYL 500 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER TTEMVE-0150LFB -THERMAQ EVOCYL 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0180LFB -THERMAQ EVOCYL 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0210LFC -THERMAQ EVOCYL 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0250LFC -THERMAQ EVOCYL 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0300LFC -THERMAQ EVOCYL 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0350LFC -THERMAQ EVOCYL 350 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0400LFC -THERMAQ EVOCYL 400 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0450LFC -THERMAQ EVOCYL 450 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0500LFC -THERMAQ EVOCYL 500 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0150LFB -THERMAQ EVOCYL 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0180LFB -THERMAQ EVOCYL 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0210LFC -THERMAQ EVOCYL 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0250LFC -THERMAQ EVOCYL 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0300LFC -THERMAQ EVOCYL 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0350LFC -THERMAQ EVOCYL 350 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0400LFC -THERMAQ EVOCYL 400 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0450LFC -THERMAQ EVOCYL 450 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0500LFC -THERMAQ EVOCYL 500 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER
Factor:
Thermaq Ltd
Company Name
Thermaq Ltd
Address
Sandbeds Trading Estate Dewsbury Road Ossett
Postcode
WF5 9ND
Country
West Yorkshire
General Email
steve.woollas@rmcylinders.com

View All Listings by this Company

Print This Approval


#1909105

THERMAQ UNICYL range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909105
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre,
Marking:
THERMAQ UNICYL ON CYLINDER THERMAQ UNICYL, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TTUMVD-0090LFC -THERMAQ UNICYL 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0120LFB -THERMAQ UNICYL 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0150LFB -THERMAQ UNICYL 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0180LFB -THERMAQ UNICYL 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0210LFC -THERMAQ UNICYL 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0250LFC -THERMAQ UNICYL 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0300LFC -THERMAQ UNICYL 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0090LFC -THERMAQ UNICYL 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0120LFB -THERMAQ UNICYL 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0150LFB -THERMAQ UNICYL 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0180LFB -THERMAQ UNICYL 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0210LFC -THERMAQ UNICYL 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0250LFC -THERMAQ UNICYL 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0300LFC -THERMAQ UNICYL 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVE-0150LFB -THERMAQ UNICYL 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTUMVE-0180LFB -THERMAQ UNICYL 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTUMVE-0210LFC -THERMAQ UNICYL 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTUMVE-0250LFC -THERMAQ UNICYL 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTUMVE-0300LFC -THERMAQ UNICYL 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTUMVS-0150LFB -THERMAQ UNICYL 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTUMVS-0180LFB -THERMAQ UNICYL 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTUMVS-0210LFC -THERMAQ UNICYL 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTUMVS-0250LFC -THERMAQ UNICYL 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTUMVS-0300LFC -THERMAQ UNICYL 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER.
Factor:
Thermaq Ltd
Company Name
Thermaq Ltd
Address
Sandbeds Trading Estate Dewsbury Road Ossett
Postcode
WF5 9ND
Country
West Yorkshire
General Email
steve.woollas@rmcylinders.com

View All Listings by this Company

Print This Approval


#1909106

JOULE CYCLONE range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909106
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre, 350 litre, 400 litre, 450 litre, 500 litre.
Marking:
JOULE ON CYLINDER, JOULE CYCLONE, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TCEMVD-0090LFD -JOULE CYCLONE 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0120LFD-JOULE CYCLONE 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0150LFD -JOULE CYCLONE 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0180LFD -JOULE CYCLONE 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0210LFC -JOULE CYCLONE 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER TCEMVD-0250LFC -JOULE CYCLONE 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0300LFC -JOULE CYCLONE 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0350LFC -JOULE CYCLONE 350 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0400LFC -JOULE CYCLONE 400 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0450LFC -JOULE CYCLONE 450 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0500LFC -JOULE CYCLONE 500 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0090LFB -JOULE CYCLONE 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0120LFB -JOULE CYCLONE 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0150LFB -JOULE CYCLONE 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER TCEMVI-0180LFB -JOULE CYCLONE 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0210LFC -JOULE CYCLONE 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0250LFC -JOULE CYCLONE 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0300LFD-JOULE CYCLONE 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0350LFC -JOULE CYCLONE 350 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER TCEMVI-0400LFC -JOULE CYCLONE 400 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0450LFC -JOULE CYCLONE 450 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0500LFC -JOULE CYCLONE 500 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER TCEMVE-0150LFB -JOULE CYCLONE 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0180LFB -JOULE CYCLONE 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0210LFC -JOULE CYCLONE 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0250LFC -JOULE CYCLONE 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0300LFC -JOULE CYCLONE 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0350LFC -JOULE CYCLONE 350 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0400LFC -JOULE CYCLONE 400 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER TCEMVE-0450LFC -JOULE CYCLONE 450 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0500LFC -JOULE CYCLONE 500 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0150LFB -JOULE CYCLONE 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0180LFB -JOULE CYCLONE 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0210LFC -JOULE CYCLONE 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TECMVS-0250LFC -JOULE CYCLONE 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TECMVS-0300LFC -JOULE CYCLONE 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0350LFC -JOULE CYCLONE350 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER TCEMVS-0400LFC -JOULE CYCLONE 400 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0450LFC -JOULE CYCLONE 450 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0500LFC -JOULE CYCLONE 500 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER
Factor:
JOULE HOT WATER SYSTEMS
Company Name
JOULE HOT WATER SYSTEMS
Address
4 VALENCIA PARK GILCAR WAY WAKEFIELD EUROPORT
Postcode
WF10 5QS
Country
WEST YORKSHIRE

View All Listings by this Company

Print This Approval


#1909107

ZIP AQUAFLO II range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909107
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre,
Marking:
ZIP AQUAFLO II ON CYLINDER BODY ZIP AQUAFLO II, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
AF3090-ZIP AQUFLO II 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3120 -ZIP AQUAFLO II 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER AF3150 -ZIP AQUAFLO II 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3180 -ZIP AQUAFLO II 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3210 -ZIP AQUAFLO II 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3250 -ZIP AQUAFLO II 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3300 -ZIP AQUAFLO II 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4090 – ZIP AQUAFLO II 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4120 – ZIP AQUAFLO II 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4150 - ZIP AQUAFLO II 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4180 - ZIP AQUAFLO II 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4210 - ZIP AQUAFLO II 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4250 - ZIP AQUAFLO II 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4300 - ZIP AQUAFLO II 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF6150 - ZIP AQUAFLO II 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF6180 - ZIP AQUAFLO II 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER AF6210 - ZIP AQUAFLO II 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF6250 - ZIP AQUAFLO II 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF6300 - ZIP AQUAFLO II 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF5150 - ZIP AQUAFLO II 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5180 - ZIP AQUAFLO II 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5210 - ZIP AQUAFLO II 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5250 - ZIP AQUAFLO II 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5300 - ZIP AQUAFLO II 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER.
Factor:
Zip Heaters (UK) Ltd.
Company Name
Zip Heaters (UK) Ltd.
Address
14/15 Bertie Ward Way Rash's Green Dereham
Postcode
NR19 1TE
Country
Norfolk
Phone
01632 853 181
General Email
sales@zipheaters.co.uk

View All Listings by this Company

Print This Approval


#1909108

PROSTEL range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909108
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre
Marking:
PROSTEL UNVENTED HEATER ON CYLINDER RM PROSTEL, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TRPMVD-0090LFC -RM PROSTEL 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0120LFB -RM PROSTEL 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0150LFB -RM PROSTEL 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0180LFB -RM PROSTEL 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0210LFC -RM PROSTEL 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0250LFC -RM PROSTEL 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0300LFC -RM PROSTEL 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER TRPMVI-0090LFC -RM PROSTEL 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0120LFB -RM PROSTEL 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0150LFB -RM PROSTEL 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0180LFB -RM PROSTEL 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0210LFC -RM PROSTEL 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0250LFC -RM PROSTEL 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0300LFC -RM PROSTEL 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0150LFB -RM PROSTEL 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0180LFB -RM PROSTEL 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER TRPMVE-0210LFC -RM PROSTEL 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0250LFC -RM PROSTEL 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0300LFC -RM PROSTEL 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER TRPMVS-0150LFB -RM PROSTEL 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0180LFB -RM PROSTEL 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0210LFC -RM PROSTEL 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0250LFC -RM PROSTEL 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0300LFC -RM PROSTEL 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER.
Factor:
RM Cylinders
Company Name
RM Cylinders
Address
4 Valencia Park, Gilcar Way, Wakefield Europort
Postcode
WF10 5QS
Country
West Yorkshire

View All Listings by this Company

Print This Approval


#1911012

Range of “Excelsior” stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911012
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2). The above sizes on the approval to be modified to the below: 22mm or 28mm compression connection (manifold) secondary inlet, 22mm or 28mm stub connection secondary outlet 22mm stub or ½”F BSP secondary return 22mm stub connections coil1 inlet and outlet 28mm or 32mm stub connections cold inlet and outlet
Marking:
Fabdec, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
Product Range: External expansion ranges: Excelsior Direct:80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior indirect: 80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Solar Direct: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Solar Indirect: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Heat Pump (single coil): 150L, 175L, 215L, 255L, 305L,400L, 500L Excelsior Heat Pump (twin coil): 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Direct slim line: 100L, 130L, 150L, 175L, 210L Excelsior indirect slim line: 100L, 130L, 150L, 175L, 210L Excelsior Direct super slim line: 80L, 100L, 130L, 150L, 165L Excelsior indirect super slim line: 80L, 100L, 130L, 150L, 165L Excelsior Renewables’, slim line: 100L. 130L, 150L, 175L, 210L Excelsior Buffer: 80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L
Factor:
Fabdec Ltd
Company Name
Fabdec Ltd
Address
Grange Road Ellesmere Shropshire
Postcode
SY12 9DG

View All Listings by this Company

Print This Approval


#1911034

Range of MAXXflo EVO free standing gas fired stainless steel unvented storage cylinders. The heaters are supplied with temperature and pressure relief valves (rated 10.0 bar @ 95°C), pressure reducing valve (rated 6.0 bar) & expansion relief valve (rated 8.0 bar). The manifold incorporates a stainless-steel strainer, flexible hose, expansion vessel and approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 7.5 bar. Cold water supply only.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911034
Expiry date:
30/11/2024
Size:
1½” BSP (M)
Marking:
Andrews Water Heaters & technical information on adhesive label.
Installation Requirements:
R001 R530 R140 R360
Model:
CWH 30/201 (30kW heat input with 200 litre tank) CWH 30/301 (30kW heat input with 300 litre tank) CWH 60/201 (60kW heat input with 200 litre tank) CWH 60/301 (60kW heat input with 300 litre tank) CWH 90/302 (90kW heat input with 300 litre tank) CWH 120/302 (120kW heat input with 300 litre tank)
Factor:
Andrews Water Heaters
Company Name
Andrews Water Heaters
Address
Baxi Commercial Division Wood Lane Erdington
Postcode
B24 9QP
Country
Birmingham
Phone
0845 070 1056
General Email
andrews@andrews-waterheaters.co.uk

View All Listings by this Company

Print This Approval


#1911059

Range of “Mixergy” stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911059
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2).
Marking:
MIXERGY, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
MIXERGY DIRECT CYLINDER 90L, 130L, 150L, 175L & 215L MIXERGY INDIRECT CYLINDER 130L, 150L, 175L, 215L & 305L
Factor:
Mixergy Ltd.
Company Name
Mixergy Ltd.
Address
2 Canal View Wharf Farm Eynsham
Postcode
OX29 4DB
Country
Oxfordshire

View All Listings by this Company

Print This Approval


#1911060

BTMB Range of stainless steel indirect unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911060
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2).
Marking:
SAHP, Model number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
BTMB 130 BTMB 200 & BTMB 300
Factor:
SAHP LIMITED
Company Name
SAHP LIMITED
Address
UNIT 2 GALIFORD ROAD MALDON ESSE
Postcode
CM9 4XD

View All Listings by this Company

Print This Approval


#2006003

Range of indirectly heated stainless-steel storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. A safety kit (manifold) consisting of a check valve, strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.5 bar is provided. A tundish, expansion vessel and an approved filling loop is also supplied Maximum working pressure secondary circuit 5.5 bar. Maximum operating pressure primary circuit 2.5 bar. Maximum operating temperature 70˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2006003
Expiry date:
30/06/2025
Marking:
Mitsubishi and Ecodan on front of unit. Mitsubishi, model and technical info including pressures and capacity on adhesive label on top of unit.
Installation Requirements:
R001 R140 R530 R360
Model:
EHPT20X-MHCW. EHST20C-MHCW. EHST20D-MHCW.
Manufacturer:
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Address
Nettlehill Road, Houston Industrial Estate, Livingston
Postcode
EH54 5EQ
Country
United Kingdom
Phone
01405 44 55 00

View All Listings by this Company

Print This Approval


#2007040

Fabdec ‘Excelsior’ ranges of direct, indirect, solar direct and solar indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar 95°C, an inlet manifold consisting of an in-line pressure reducing valve adjustable between 2.7 & 3.3 bar (but factory set @ 3.0 bar), an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a pre-set expansion relief valve set at 6.0 bar and a strainer. The product is supplied with a tundish. Maximum supply pressure to pressure reducing valve is 10.0 bar. Maximum working pressure Primary circuit 6.0 bar. Maximum working pressure Secondary circuit 5.5 bar. Maximum operating temperature 85˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2007040
Expiry date:
31/07/2025
Note:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°C.
Size:
See model
Marking:
Adhesive label on side of cylinder with manufacturers name (Fabdec), model, address and technical information including temperature, capacity and pressure.
Installation Requirements:
R001 R140 R360
Model:
Internal expansion ranges. Excelsior Direct, Indirect, Solar Direct & Solar Indirect Cylinders range: 80ltr, 130ltr, 150ltr, 175ltr, 215ltr, 255ltr, 300ltr, 400ltr, 500ltr.
Manufacturer:
Fabdec Ltd
Company Name
Fabdec Ltd
Address
Grange Road Ellesmere Shropshire
Postcode
SY12 9DG

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 3

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.