Back To Directory SectionsPressure gauge with brass body and a plastic case. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C
Range of combined bath filler, waste and overflow assemblies in various finishes. Maximum operating temperature 60ºC.
Range of flexible joints incorporating an EPDM (inner & outer) joint with a steel reinforcing ring and two carbon steel flanges. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.
External pump docking station with a plastic body and NBR ‘O’ rings. Cold water use only.
Range of radial flowmeters incorporating EPDM ‘O’-rings. The type 10088400 model has a black plastic body and threaded inlet. The type 10088402 model has a pale olive green plastic body with a threaded brass inlet incorporating a plastic filter. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Plastic bodied flow sensor with silicone gaskets. Maximum working pressure 17.5 bar. Maximum operating temperature 85°C.
Range of in line regulating valves DZR brass bodies, EPDM ‘O’-rings and PTFE seals. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Y type fittings incorporating brass body and NBR washer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Thermally activated water saving valve with a plastic body and non-return valves on the hot and cold outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Water hammer arrestor with brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Y type fittings incorporating brass body and NBR washer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pump inverters with plastic bodies, NBR rubber and EPDM rubber seals and ‘O’-rings. The products incorporate an inline resilient trim non-return valve. Maximum working pressure 13.0 bar. Cold water use only.
Bypass valve assembly with a plastic body and push/pull operating method to switch flows between different outlets. The product incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Cold water use only.
Union ball, non-return valve with a plastic PVC body. Maximum working pressure 10.0 bar. Cold water use only.
Range of three or four-hole single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Four hole models Incorporate quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to a shower outlet.. Three hole models Incorporate a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. The product is supplied with a shower hose and shower handset. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of concealed thermostatic mixing valves with DZR brass bodies incorporating a thermostatic cartridge controlling the temperature. The inlets incorporate asingle check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Permanent filling/ pressurisation device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. In the event of a fall in system pressure, and only if the mains pressure is adequate, a solenoid valve operates to allow water into the system. At all other times a second solenoid valve drains the fill chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 6.0 Bar. Cold water use only.
Range of pressure transmitters with stainless steel bodies. Maximum working pressure 10.0 to 200.0 bar (please refer to model). Maximum operating temperature 100°C.
Range of aerators with plastic bodies and chrome plated brass housing. Open outlet use only. Maximum operating temperature 65°C
Range of wall mounted handwash basins with copper piping and PTFE orings. Maximum working pressure 8.0bar. Maximum operating temperature 85°C
Page 8 of 12
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.