Heaters

Section Code 1465 : Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.

Back To Directory Sections

#2201345

Range of wall mounted, gas-fired, condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The inlets to the domestic hot water and primary circuits each have a screwdriver operated angled spherical valve. Both include a ½” BSP (M) connection for a filling link. The Greenstar CDi models only are supplied with an integral charging link (CAB device) verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 82°C. Maximum operating temperature of secondary circuit is 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2201345
Expiry date:
31/01/2027
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
Worcester and Wocester logo on front cover. Worcester, Worcester logo, model number, pressure, temperature and other technical information on data label inside boiler. (Worcester is a brand of Bosch).
Installation Requirements:
R001 R360
Proviso:
Greenstar CDi models: Supplied with a filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Greenstar Si models: Not supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
7-733-600-056 Greenstar 36CDi Compact ErP, 7-733-600-059 Greenstar 36CDi Compact ErP LPG, 7-733-600-055 Greenstar 32CDi Compact ErP, 7-733-600-058 Greenstar 32CDi Compact ErP LPG, 7-733-600-054 Greenstar 28CDi Compact ErP, 7-733-600-057 Greenstar 28CDi Compact ErP LPG, 7-733-600-050 Greenstar 25Si Compact ErP, 7-733-600-051 Greenstar 25Si Compact ErP LPG, 7-733-600-052 Greenstar 30Si Compact ErP, 7-733-600-053 Greenstar 30Si Compact ErP LPG.
Factor:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company

Print This Approval


#2205321

Range of electric combination boilers providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar). The DHW inlet and outlet incorporate spherical servicing valves. Fittited with a CAB device keyless filling link, verifired by test, suitable for category 3 backlfow protection. Maximum working pressure on central heating circuit 2.5 bar & Domestic Hot Water 10bar. Maximum operating temperature 80°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2205321
Expiry date:
31/05/2027
Size:
15mm compression x 22mm compression.
Marking:
E.C.A on front casing. Manufacturer, address, model no, QR code and other technical information on side panel.
Installation Requirements:
R001 R140
Model:
8116270010 - Arceus/Cure plus/Electus EK 12 MT UK, 8116271010 - Arceus/Cure plus/Electus EK 15 MT UK, 8116272010 - Arceus/Cure plus/Electus EK 18 MT UK 8116273010 - Arceus/Cure plus/Electus EK 24 MT UK & 8116274010 - Arceus/Cure plus/Electus EK 27 MT UK
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Organize Sanayi Bolgasi 3 Kisim Mustafa Kemal Bulvari N013 Turkey

View All Listings by this Company

Print This Approval


#2207350

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207350
Expiry date:
31/07/2027
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
Ideal heating printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
Logic Max Combi² C24 – UIN 228334, Logic Max Combi² C30 – UIN 228335, Logic Max Combi² C35 – UIN 228336, Logic + Combi² C24 – UIN 228329, Logic + Combi² C30 – UIN 228330, Logic + Combi² C35 – UIN 228331, Logic Combi² C24 – UIN 228307, Logic Combi² C30 – UIN 228308, Logic Combi² C35 – UIN 228309.
Manufacturer:
Ideal Boilers
Company Name
Ideal Boilers
Address
PO Box 103 National Avenue Kingston upon Hull
Postcode
HU5 4JN
Country
East Yorkshire
Phone
+44 (0) 1482 492251

View All Listings by this Company

Print This Approval


#2001382

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a plastic flow restrictor The primary circuit incorporates isolation valves on the flow and return. Maximum working pressure of secondary circuit is 6.0 bar. Maximum working pressure of primary circuit is 2.5 bar. Maximum operating temperature 60°C. Cold water supply only.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2001382
Expiry date:
31/01/2025
Size:
15mm compression (secondary). 22mm compression (primary).
Marking:
Vokera by Riello on face. Vokera, model, pressure and other technical information on inside of cover.
Installation Requirements:
R001 R140
Proviso:
The filling loop supplied must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
Unica Max 30C, 35C & 40C WALL MOUNTED COMBINATION BOILERS
Factor:
Vokera Ltd.
Company Name
Vokera Ltd.
Address
Borderlake House, Unit 7 Riverside Industrial Estate, London Colney
Postcode
AL2 1HG

View All Listings by this Company

Print This Approval


#2207374

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207374
Expiry date:
31/07/2027
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
Ideal heating printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
INDEPENDENT COMBI² C24 INDEPENDENT COMBI² C30 INDEPENDENT COMBI² C35
Factor:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Kingston Upon Hull
Postcode
HU5 4JN
Country
East Yorkshire
Phone
0870 8498056
General Email
enquiries@idealheating.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 6 of 8

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.