Section Code 0684 : Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
Back To Directory SectionsSensor control unit, flow is controlled using a solenoid valve assembly and is activated via infra-red non touch operation. The Art 30622 model has an in-line spherical valve on each inlet, as well as an approved check valve cartridge, however the complete assemblies have not been fully tested to demonstrate that they provide backflow protection The Art 30629 & 33725 model is supplied with two angled isolation valves and two stainless steel braided PEX lined flexible hose assemblies with ⅜” captive nut end connections, which are intended to connect to the tee piece installed prior to the solenoid valve. The tee piece inlets incorporate a combined washer and stainless steel strainer and an approved check valve cartridge, however the complete assemblies have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet, fixed electronically controlled tap assemblies (chromium plated brass), incorporating a solenoid valve controlling the flow which is actuated via infrared sensor. The spouts incorporate adjustable combined plastic and rubber aerators and the inlets incorporate plastic strainers. Temperature can be set via an access point on the side of the valve. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet, fixed electronically controlled tap assemblies (chromium plated brass), incorporating a solenoid valve controlling the flow which is actuated via infrared sensor. The spouts incorporate plastic aerators and the inlets incorporate plastic strainers. Temperature can be set via an access point on the side of the valve. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated stainless steel body). Flow is controlled by a solenoid valve that is activated via an infrared sensor. The spout outlets incorporate plastic aerators. Models with two inlets are supplied with hoses that incorporate stainless steel strainers and an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models with single inlets incorporate stainless steel strainers. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled combination tap assembly (chromium plated brass). The flow is controlled via solenoid valve which is actuated by an infra-red sensor and the temperature is controlled independently via a single lever operating member (388MCHLH15, 398MCHLH15, 488MCHLH15 & 498MCHLH15). The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of deck mounted single hole, single outlet (fixed) single feed electronically controlled tap assemblies (chromium plated brass). Flow is controlled via a solenoid valve (housed within a control unit) activated via an infra-red sensor. The inlet to the control unit incorporates a plastic flow regulator. The spout outlet incorporates a plastic or metal aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) electronically operated tap assemblies (chromium plated brass). The flow is controlled by a solenoid valve which is actuated via an infrared sensor on the spout. The spout incorporates a plastic flow straightener. Adjustable manual temperature control via a lever type operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve that is activated via an infrared sensor. Certain models incorporate a mixer spout which incorporates a manual temperature control by a single lever on the side of the body. The models are also supplied with stainless steel braided PEX lined flexible hose connectors and the spout outlets also incorporate a plastic flow straighter. Models are also supplied with stainless steel strainers located on the inlet of the solenoid. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet, electronically operated tap assemblies (chromium plated brass). The flow is controlled by a solenoid valve and activated via an infra-red sensor. The inlet hoses incorporate a stainless-steel strainer and an isolation valve and the spout outlet incorporates a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 40°C.
Page 2 of 18
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.