Directory Search Results

Print List

#2011344

Range of single flush siphonic WC outlet valves comprising of a plastic body, LDPE diaphragm washer and stainless steel C link. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2011344
Size:
See model.
Marking:
Derwent Macdee (brand of Wirquin) and made in England on cap. Date of production clock MM/YY on body.
Installation Requirements:
R001
Expiry date:
30/11/2025
Model:
Metro Rapid Square siphon: DSY7925 - METRO RAPID SQUARE 7.5” SIPHON 2.25” C LINK. DSY8025 - METRO RAPID SQUARE 8“ SIPHON 2.25” C LINK. DSY8125 - METRO RAPID SQUARE 9” SIPHON 2.25” C LINK. DSY8225 - METRO RAPID SQUARE 9.5” SIPHON 2.25” C LINK. DSY8338 - METRO RAPID SQUARE 10” SIPHON 4 3/8” C LINK. Metro Rapid Round siphon: DSY7125 - METRO RAPID 7.5” ROUND SIPHON 2.25” C LINK. DSY7225 - METRO RAPID 8” ROUND SIPHON 2.25” C LINK. DSY7325 - METRO RAPID 9” ROUND SIPHON 2.25” C LINK. DSY7425 - METRO RAPID 9.5” ROUND SIPHON 2.25” C LINK. DSY7538 - METRO RAPID 10” ROUND SIPHON 4 3/8” C LINK. Metro Rapid Oblong siphon: DSY8725 - METRO RAPID OBLONG 7.5”SIPHON 2.25” C LINK. DSY8825 - METRO RAPID OBLONG 8”SIPHON 2.25” C LINK. DSY8875 - METRO RAPID OBLONG 8.5”SIPHON 2.25” C LINK. DSY8925 - METRO RAPID OBLONG 9”SIPHON 2.25” C LINK. DSY9025 - METRO RAPID OBLONG 9.5”SIPHON 2.25” C LINK. DSY9138 - METRO RAPID OBLONG 10”SIPHON 4 3/8” C LINK. Metro Siphon: DSY0538 - 10” METRO SIPHON 4 3/8” C LINK. DSY0425 - 9.5” METRO SIPHON 2.25” C LINK. DSY0325 - 9” METRO SIPHON 2.25” C LINK. DSY0275 - 8.5” METRO SIPHON 2.25” C LINK. DSY0225 - 8” METRO SIPHON 2.25” C LINK. DSY0125 - 7.5” METRO SIPHON 2.25” C LINK.
Product Images

Approval Holder:
Wirquin Ltd
Company Name
Wirquin Ltd
Address
Unit 3 Alpha Court Thorne Doncaster
Postcode
DN8 5TZ
Country
United Kingdom
Phone
01302 312252
General Email
mick.kirby@wirquin.co.uk

View All Listings by this Company
Manufacturer:
Wirquin Ltd
Company Name
Wirquin Ltd
Address
Unit 3 Alpha Court Thorne Doncaster
Postcode
DN8 5TZ
Country
United Kingdom
Phone
01302 312252
General Email
mick.kirby@wirquin.co.uk

View All Listings by this Company

Print This Approval


#2103008

WC dual flush outlet valve with plastic body silicone rubber seal. The valve is operated via a lift assembly with an either full or reduced flush and incorporates an internal overflow. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2103008
Size:
48mm
Marking:
Bestter and model on valve body.
Installation Requirements:
R001 R571
Expiry date:
31/03/2026
Model:
T8700
Product Images

Approval Holder:
Bestter(Xiamen) Technology lnc.
Company Name
Bestter(Xiamen) Technology lnc.
Address
No.601, Tonghong Road, Tong'an Park Tong'an Industrial Zone, Xiamen City , China

View All Listings by this Company
Manufacturer:
Bestter(Xiamen) Technology lnc.
Company Name
Bestter(Xiamen) Technology lnc.
Address
No.601, Tonghong Road, Tong'an Park Tong'an Industrial Zone, Xiamen City , China

View All Listings by this Company

Print This Approval


#2011035

Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2011035
Note:
There are no pipework connections on this product to facilitate the filling of the space heating circuit. The installer must provide this separately.
Size:
Domestic hot water and District heating circuits: ¾” BSP (M) inlet/outlet. Space heating circuit: ¾” BSP captive nut inlet/outlet.
Marking:
YGHP on front cover. YGHP, model number, company address and technical info on adhesive label on side of body.
Installation Requirements:
R001 R140 R360 R511
Expiry date:
30/11/2025
Proviso:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
YGINDRADSTD33/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 33kW / HTG 10kW. YGINDRADSTD40/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 40kW / HTG 10kW. YGINDRADSTD50/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 50kW / HTG 10kW. YGINDRADSTD60/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 60kW / HTG 10kW. YGINDRADSTD75/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 75kW / HTG 10kW. YGINDRADSTD90/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 90kW / HTG 10kW. YGINDRADSTD120/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 120kW / HTG 10kW. Models added March 2021: YGINDUFHSTD33/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 33kW / HTG 10kW YGINDUFHSTD40/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 40kW / HTG 10kW YGINDUFHSTD50/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 50kW / HTG 10kW YGINDUFHSTD60/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 60kW / HTG 10kW YGINDUFHSTD75/15.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 75kW / HTG 15kW YGINDUFHSTD90/15.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 90kW / HTG 15kW YGINDUFHSTD120/30.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 120kW / HTG 30kW
Product Images

Approval Holder:
YGHP Ltd
Company Name
YGHP Ltd

View All Listings by this Company

Print This Approval


#2101035

Range of stainless-steel heat exchangers. Maximum working pressure of primary Circuit 3.0 bar. Maximum working pressure of secondary Circuit 10.0 bar. Maximum operating temperature 80˚C

Section:
1350 Heat Exchangers
Size:
Primary Circuit ¾” captive nut x ¾” BSP (M) Sanitary Circuit 21mm (OD) Spigot Fitting x ½” BSP (M)
Marking:
Condevo SpA, serial number and date of manufacture (DD/MM/YY) on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/01/2026
Model:
Type E 12439 PP11CE6V02, PP21CE6V02 & PP33CE6V02. Type E 12440 PP10CE6H02, PP22CE6H02 & PP34CE6H02.
Product Images

Approval Holder:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company
Manufacturer:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company

Print This Approval


#2012353

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
Inta logo, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
HIPER2TPSZ80 HIPER2SPSW80 HIPER2SPSW80IS HIPER2SPSW80ZE
Product Images

Approval Holder:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 84 of 1576

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.