#250702719

Range of WC dual flush drop valves with ABS bodies and silicon seals. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal, adjustable height overflow.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
250702719
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
Open outlet and cold water use only.
Size:
1 1/2" BSP (M) (MFV1C and MFV2C) 2" BSP (M) (MFV3C and MFV4C)
Marking:
Multikwik website and NSG3338 on body or Multikwik Website on base of flush valve
Installation Requirements:
R001 R556 R571
Expiry date:
31/07/2030
Model:
0702120 MFV1C 0702121 MFV2C 0702122 MFV3C 0702123 MFV4C

Print This Approval


#2311108

Range of WC dual flush drop valves with ABS bodies and silicone seals. The valves are operated via a two push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2311108
Size:
2” BSP (M)
Marking:
UK Bathrooms Ltd and product info on body.
Installation Requirements:
R001 R571 R580 R581
Expiry date:
30/11/2028
Model:
B218M B228 B2650

Approval Holder:
UK Bathrooms Ltd
Company Name
UK Bathrooms Ltd
Address
Aston House Redburn Road Newcastle Upon Tyne
Postcode
NE5 1NB

View All Listings by this Company

Print This Approval


#251002020

Range of ultrasonic dry type water meters with brass bodies. Maximum working pressure 16.0 Bar. Maximum operating temperature 50.0°C.

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See Models
Marking:
BAYLAN, model number and other technical information on meter face. Flow arrow on body
Installation Requirements:
R001
Expiry date:
31/10/2030
Model:
ST-15. DN15 - thread size ¾” BSP (M). Lengths - 110mm, 115mm, 130mm, 145mm, 165mm, 170mm, 190mm. ST-20. DN20 - thread size 1” BSP (M). Lengths - 110mm, 115mm, 130mm, 135mm, 165mm, 175mm, 190mm, 200mm, 220mm. ST-25. DN25 - thread size 1 ¼” BSP (M). Lengths - 175mm, 199mm, 200mm, 210mm, 225mm. ST-32. DN32 - thread size 1 ½” BSP (M). Lengths - 110mm, 150mm, 175mm, 199mm, 200mm ST-40. DN40 - thread size 2” BSP (M). Lengths - 200mm, 220mm.

Approval Holder:
BAYLAN OLCU ALETLERI SAN. TICARET
Company Name
BAYLAN OLCU ALETLERI SAN. TICARET
Address
ANONIM SIRKETI AOSB 10032 SOKAK NO 16 CIGLI IZMIR TURKEY

View All Listings by this Company
Manufacturer:
BAYLAN OLCU ALETLERI SAN. TICARET
Company Name
BAYLAN OLCU ALETLERI SAN. TICARET
Address
ANONIM SIRKETI AOSB 10032 SOKAK NO 16 CIGLI IZMIR TURKEY

View All Listings by this Company

Print This Approval


#250302723

Range of multistage centrifugal pumps with stainless steel impellers, intermediate chambers, shaft and outer sleeve. The DPV(M/S) models and DPV(S) models can also incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressures: Existing models: DPV models 10.0 bar, DPVM models with an oval flange or VME models with integral check valve 16.0 bar, All other DPVM models 25.0 bar. DPV(S) models with an oval flange or DPV(S)(E) models with integral check valve 16.0 bar, All other DPV(S) models and DPH(S)I models 25.0 bar. Maximum operating temperatures: DPHM, DPVE and DPVME models with integral check valve 60°C, all other model variants 100°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250302723
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DPHM 2/4/6 B: 1¼” BSP (F) inlet x 1” BSP (F) outlet. DPV(M/S)(F/E/V/T) 2/4/6 B: Oval flange: DN25, DN32. Round flange: DN25, DN32. External threaded: 1½” BSP (M), Victaulic: DN32 and Tri-clamp: DN32. DPV(S) (F/E/V/T) 10 B/15 B/15 C: Oval flange: DN40, DN50. Round flange: DN40, DN50. External threaded: 1½” BSP (M), Victaulic: DN50 and Tri-clamp: DN50. DPV(S)F 25/40/60/85/125 B: Round flange: DN65, DN80, DN100, DN125. DPH(S)I 2/4/6 B: 1¼” BSP or NPT (F). DPH(S)I 10/15 B/C: 2” BSP or NPT (F).
Marking:
DPVF & logo, model name, PN, WRAS and technical information on adhesive label on body.
Installation Requirements:
R001 R415
Expiry date:
31/03/2030
Model:
DPHM x yy B. Where: x = flow rate m³/h (2, 4 or 6). yy = no. of stages ranges 1-6 stages. ------------------------------------- DPV(M/S)(F/E/V/T) x yy B/C Where: V = Vertically oriented (AISI 304) with coupling. VS = Vertically oriented (AISI 316) with coupling. No indication (V/VS only) = oval flange. F (VF/VSF) = round flange. E (VE) = external thread. V (VV/VSV) = Victaulic. T (VT/VST) = Triclamp. x = flow rate m³/h (2, 4, 6, 10, 15). yy = no. of stages DPV(M/S)(F/E/V/T)……2 B 1-30 stages. DPV(M/S)(F/E/V/T)……4/6 B 1-26 stages. DPV(S)(F/E/V/T)……10 B 1-21 stages. DPV(S)(F/E/V/T)……15 B/C 1-17 stages. -------------------------------------- DPV(S) F xx yy B. Where: V = Vertically oriented (AISI 304) with coupling. VS = Vertically oriented (AISI 316) with coupling. F (VF/VSF) = round flange. x = flow rate m³/h (25, 40, 60, 90(model 85) or 125). yy = no. of stages ……25 B 1-12 stages. ……40/60 B 1-10 stages. ……85 B 1-6 stages. ……125 B 1-4 stages. -------------------------------------- DPHI x yy = Vertically oriented (AISI 304). DPHSI x yy = Vertically oriented (AISI 316). Where: I = Inner thread connection. x = flow rate m³/h (2, 4, 6, 10 or 15). yy = no. of stages DPH(S)I 2/4/6 B 1-14 stages. DPH(S)I 10 B/15 B/15 C 1-8 stages.

Approval Holder:
Duijvelaar Pompen B.V.
Company Name
Duijvelaar Pompen B.V.
Address
Kalkovenweg 13 2401 LJ Alpen aan den Rijn
Country
Netherlands
Phone
0031 0172 488388

View All Listings by this Company

Print This Approval


#241102725

Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 2.0 bar (MS(s) models), 4.0 bar (AM(E) models) Maximum operating temperature 85°C

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241102725
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
TERAL, model, size & technical information on date label on body. Flow arrow on cover.
Installation Requirements:
R001 R415
Expiry date:
30/11/2029
Model:
MS(m)XXX-XX-E 1.m: different phase. --m: single phase, none: three phases 2.XXX: Rated flow (L/min) 3.XX: Rated power(kW). 4.E: E type end connection mode and size -- Rated flow(70-120m3/h): G1¼"XG1" -- Rated flow(210m3/h): G1½"XG1¼" -- Rated flow (370 m3/h): G2"XG1¼ AM(E) XXxXX (B) X/X-X XX(S) 1. E: Intelligent Type 2. XX: Inlet diameter (mm), range: 25,32,40,50 mm. 3. XX: Outlet diameter (mm), range: 25,32,40,50 mm. 4. B: alternative pump group 4. X/X: number of impeller /number of smaller impeller (if any) 5. X: motor frequency 6. XX: Rated power(kW) 7. S: different phase (S: single phase, none: three phases.)

Print This Approval



Back To Directory Sections

Page 585 of 640

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.